ABB Low Voltage Drives ACS550-U1-059A-4+K466+L502 ACS550 AC Drive, 3-380-480V In, 40HP, 59A, Type 1/IP21, 1.1 overload, Advanced, 27.1 x 8…
Alternate Item Number: 3AUA0000014547
UPC: 662348048566
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 40 HP / 59 Amp output rating
- 3-phase, 380-480V AC input voltage
- Ethernet connectivity for Modbus/TCP and EtherNet/IP
- Pulse encoder input for closed-loop control
- IP21 / Type 1 enclosure rating
- Compact wall-mount design (27.1 x 8 x 10.3 in)
Specifications
Control Panel | Advanced |
Frame Size | R4 |
Input Phase | 3-Phase |
IP Rating | IP21 |
Options | Ethernet (Modbus/TCPEtherNet/IP) Pulse encoder |
Output Current | 59 |
Output Phase | 3-Phase |
UL Type | 1 |
Voltage | 480 |
Voltage Range | 380-480 |
Package Dimensions (L x W x H) | 10.3 in x 8 in x 27.1 in |
Package Dimensions (L x W x H) | 26.162 cm x 20.32 cm x 68.834 cm |
Package Weight (Imperial) | 53.000 L |
Package Weight (Metric) | 24.041 kg |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the power and voltage range for ACS550 standard drives?
The drives support 3-phase input power from 208 to 240 V (0.75-100Hp), 380 to 480 V (1-550Hp), and 500 to 600 V (1.5-150Hp).
What is the operating frequency range for motor connection?
The motor connection frequency range is from 0 to 500 Hz.
What are the acceleration and deceleration time limits?
Acceleration and deceleration times can be set between 0.1 to 1800 seconds.
Does the drive have built-in serial communication?
Yes, the drive has built-in Modbus RTU protocol for serial communication via RS 485.
What is the recommended ambient temperature range for operation?
The ambient temperature range for operation is 15 to 40°C (5 to 104°F).
What is the maximum relative humidity allowed for the drive?
The relative humidity must be lower than 95%, without condensation.
What types of analog inputs are available?
There are two analog inputs that accept voltage signals (0-10 V) or current signals (0-20 mA).
What is the auxiliary voltage provided by the drive?
The drive provides an auxiliary voltage of 24 V DC ±10% with a maximum current of 250 mA.
How many digital inputs does the drive have and what is their voltage range?
The drive has six digital inputs that operate with 12 V to 24 V DC using internal or external supply, supporting PNP and NPN.
What are the specifications for the relay outputs?
There are three relay outputs with a maximum switching voltage of 250 V AC/30 V DC and a maximum switching current of 6 A.