ABB Low Voltage Drives ACS550-U1-059A-4+B055+L511 ACS550 AC Drive, 3-380-480V In, 40HP, 59A, Type 12/IP55, 1.1 overload, Advanced, 29.9 x…
Alternate Item Number: 3AUA0000062147
UPC: 662348048481
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 40 HP power rating and 59A current capacity
- 3-phase input voltage: 380-480V
- Type 12/IP55 enclosure for dust and water protection
- 1.1 overload capability for enhanced durability
- Wall-mounted design with relay output extension
Specifications
Control Panel | Advanced |
Frame Size | R4 |
Input Phase | 3-Phase |
IP Rating | IP55 |
Options | Relay output extension |
Output Current | 59 |
Output Phase | 3-Phase |
UL Type | 12 |
Voltage | 480 |
Voltage Range | 380-480 |
Package Dimensions (L x W x H) | 11.2 in x 10.1 in x 29.9 in |
Package Dimensions (L x W x H) | 28.448 cm x 25.654 cm x 75.946 cm |
Package Weight (Imperial) | 75.000 L |
Package Weight (Metric) | 34.020 kg |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the input voltage range for ACS550 drives?
The drives support 3-phase input voltages of 208 to 240 V, 380 to 480 V, and 500 to 600 V, with a tolerance of +10/-15%.
What is the operating ambient temperature range?
The drives can operate in ambient temperatures between 15 to 40°C (5 to 104° F).
What are the humidity requirements for operation?
The relative humidity must be lower than 95%, and condensation is not allowed.
What certifications do the ACS550 drives hold?
The drives hold UL, cUL, C-Tick, and Gost-R approvals, and are certified to seismic criteria ICC AC-156.
What is the output frequency range for motors?
The motor output frequency can be set from 0 to 500 Hz.
What communication protocols are supported?
The drives have built-in Modbus RTU protocol and support numerous internally mountable fieldbus adapters.
What protection classes are available for ACS550 drives?
The drives are available in UL Type 1, 12, or 3R (NEMA 1, 12, or 3R) enclosures.
Are coated boards available for harsh environments?
Yes, the drives are available with coated boards for use in harsh environments.
Does the drive have harmonic reduction features?
Yes, it includes a patented swinging choke for superior harmonic reduction and an integral EMC filter as standard.
What control panel features are included?
The drives feature an advanced control panel for intuitive operation and include several assistants for commissioning and maintenance.