ABB Low Voltage Drives ACS550-PD-059A-4 GENERAL PURPOSE PACKAGED DRIVE W/ DISCONNECT SWITCH AND FUSES, Product Family: ACS550…
Alternate Item Number: 3AUA0000010301
UPC: 662348044742
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 59A output current
- 480 VAC, 3-phase input/output
- NEMA 1 / UL Type 1 (IP21) enclosure
- Wall-mounted with advanced control panel
Specifications
Package Dimensions (L x W x H) | 58 IN x 14 IN x 19 IN |
Package Dimensions (L x W x H) | 147.32 cm x 35.56 cm x 48.26 cm |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the voltage and power range for ACS550 standard drives?
The drives support 3-phase input power from 208 to 240V (0.75-100Hp), 380 to 480V (1-550Hp), and 500 to 600V (1.5-150Hp).
What serial communication protocol is built-in?
The drives have built-in RS 485 serial communication with the Modbus RTU protocol.
What is the input frequency range for these drives?
The input frequency range for the ACS550 standard drives is 48 to 63 Hz.
What is the power factor of the ABB ACS550 drives?
The power factor for these drives is 0.98.
What is the motor connection frequency range?
The motor connection frequency range is from 0 to 500 Hz.
What are the acceleration and deceleration time ranges?
Acceleration and deceleration times can be set between 0.1 to 1800 seconds.
What is the auxiliary voltage provided by the drives?
The auxiliary voltage output is 24V DC ±10%, with a maximum current of 250 mA.
How many digital inputs are available on the ACS550 drives?
There are six digital inputs that accept 12V to 24V DC with an input impedance of 2.4 kΩ and a maximum delay of 5 ms.
What are the specifications for the relay outputs?
The drives feature three relay outputs with a maximum switching voltage of 250V AC/30V DC and a maximum switching current of 6A.
What product compliance and approvals do these drives have?
The drives have UL, cUL, CSA, CE, C-TICK, and GOST-R approvals, and meet Low Voltage, Machinery, and EMC Directives.