ABB Low Voltage Drives ACS550-PD-024A-2 GENERAL PURPOSE PACKAGED DRIVE W/ DISCONNECT SWITCH AND FUSES, Product Family: ACS550…
Alternate Item Number: 3AUA0000010280
UPC: 662348044063
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 7.5 HP motor control capability
- 240 VAC input voltage, 208-240V range
- 24.2 A output current
- NEMA 1 / UL Type 1 (IP21) enclosure
- Includes disconnect switch and fuses for safety
Specifications
Color | Blue |
Connection Type | 3-Phase Input/Output |
Connection Type | 3-phase |
Connection Type | Screw Terminal |
Current Rating | 24.2 A |
Frequency | 50/60 Hz |
IP Rating | IP21 |
Material | Poly |
Mounting Type | Wall-mounted |
Mounting Type | Wall |
Nema Rating | NEMA 1 |
Nema Rating | NEMA 1 / UL Type 1 |
NEMA Rating | Type 1 |
Poles | 3P |
Poles | 3P+G |
Poles | 3-Phase |
Poles | 3 |
Series | ACS550 |
Size | 32.6 in x 7.8 in x 11.6 in |
Size | 32.6 x 7.8 x 11.6 in |
Voltage Rating | 208-240 VAC |
Voltage Rating | 240 Vac |
Package Dimensions (L x W x H) | 51 IN x 12 IN x 18 IN |
Package Dimensions (L x W x H) | 129.54 cm x 30.48 cm x 45.72 cm |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the input voltage range for ACS550 drives?
The drives support 3-phase input voltages of 208 to 240 V, 380 to 480 V, and 500 to 600 V, with a tolerance of +10/-15%.
What is the operating frequency range for the motor connection?
The motor connection frequency range is from 0 to 500 Hz.
What are the acceleration and deceleration time limits?
Acceleration and deceleration times can be set between 0.1 to 1800 seconds.
What types of analog inputs are supported?
The drives support two analog inputs for voltage signals (0-10V) and current signals (0-20mA).
What is the auxiliary voltage output?
An auxiliary voltage of 24 V DC ±10% is available, with a maximum current of 250 mA.
How many digital inputs are available on the drives?
There are six digital inputs that accept 12 V to 24 V DC with an input impedance of 2.4 kΩ.
What are the specifications for the relay outputs?
There are three relay outputs with a maximum switching voltage of 250 V AC/30 V DC and a maximum switching current of 6 A.
Does the drive have built-in serial communication capabilities?
Yes, the drive has built-in Modbus RTU protocol for serial communication via RS 485.
What is the recommended ambient temperature range for operation?
The ambient temperature range for operation is 15 to 40°C (5 to 104°F).
What is the maximum allowable relative humidity?
The relative humidity should be lower than 95%, without condensation.