ABB - Low Voltage Drives ACS550-PC-015A-4 - GENERAL PURPOSE PACKAGED DRIVE W/ CIRCUIT BREAKER DISCONNECT, Product Family: ACS550, Horsepower: 10 HP, Output Current: 15.4 A, Voltage: 480 VAC , Voltage Range: 380-480V, NEMA 1 / UL Type 1 (IP21), Mounting: Wall-mounted, Advanced Control Panel, 3-Phase Input, 3-Phase Output, Frame: R2, Product HxWxD: 32.6 in x 7.8 in x 11.6 in, Product Weight: 42 lbs

ABB Low Voltage Drives ACS550-PC-015A-4 GENERAL PURPOSE PACKAGED DRIVE W/ CIRCUIT BREAKER DISCONNECT, Product Family: ACS550…

Alternate Item Number: 3AUA0000010246

UPC: 662348041253


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB ACS550-PC-015A-4 is a 10 HP, 480V AC (380–480V range) general-purpose packaged drive designed for reliable 3-phase motor control in industrial environments. With a 15.4A output current, this drive delivers consistent performance for applications in manufacturing, HVAC, and automation systems. The NEMA 1 / UL Type 1 (IP21) enclosure protects against dust and debris, while the wall-mounted design optimizes space in tight installations. An advanced control panel enables precise motor control, energy efficiency, and operational flexibility. The integrated circuit breaker disconnect enhances safety during maintenance and servicing. Measuring 32.6 in x 7.8 in x 11.6 in and weighing 42 lbs, the ACS550-PC-015A-4 is built for compact yet robust motor control solutions. Frame size R2 ensures compatibility with standard industrial enclosures and mounting configurations.
  • 10 HP, 480V AC (380–480V range) general-purpose industrial drive
  • 15.4A output current for 3-phase motor control
  • NEMA 1 / UL Type 1 (IP21) enclosure for dust and debris protection
  • Integrated circuit breaker disconnect for safety during maintenance
  • Wall-mounted design with dimensions 32.6 in x 7.8 in x 11.6 in, 42 lbs

Specifications

Connection Type
3-Phase Input, 3-Phase Output
Connection Type
3-phase
Current Rating
15.4 A
IP Rating
IP21
Mounting Type
Wall-mounted
NEMA Rating
Type 1
Nema Rating
NEMA 1 / UL Type 1
Poles
3
Poles
3-Phase
Series
ACS550
Size
32.6 in x 7.8 in x 11.6 in
Voltage Rating
480 VAC
Voltage Rating
480 VAC (380-480V range)
Package Dimensions (L x W x H)
51 IN x 12 IN x 18 IN
Package Dimensions (L x W x H)
129.54 cm x 30.48 cm x 45.72 cm
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the input voltage and frequency range for ACS550 drives?

The drives support 3-phase input with voltage ranges of 208-240V, 380-480V, or 500-600V, and a frequency of 48 to 63 Hz.

What is the output frequency range for motor connection?

The motor connection supports an output frequency range from 0 to 500 Hz.

What are the acceleration and deceleration time limits?

Acceleration and deceleration times can be programmed from 0.1 to 1800 seconds.

What is the auxiliary voltage provided by the drive?

The drive provides an auxiliary voltage of 24 V DC ±10% with a maximum current of 250 mA.

How many digital inputs are available and their voltage range?

There are six digital inputs that accept 12 V to 24 V DC, compatible with PNP and NPN supplies.

What are the specifications for the relay outputs?

Three relay outputs are available with a maximum switching voltage of 250 V AC/30 V DC and a maximum switching current of 6 A.

Does the drive have built-in serial communication capabilities?

Yes, the drive has built-in Modbus RTU protocol for serial communication via RS 485.

What are the environmental operating temperature limits?

The ambient temperature range for operation is 15 to 40°C (5 to 104°F), with derating required above 40°C.

What is the maximum allowable relative humidity for operation?

The relative humidity must be lower than 95%, without condensation.

What types of analog inputs are available and their specifications?

There are two analog inputs supporting voltage signals (0-10V) and current signals (0-20mA), with an accuracy of ±1%.