Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ACS355-01U-02A4-2 - ACS355 AC Drive, 1-200-240V In, 0.5HP, 2.4A, Type OPEN, 1.5 overload, Blank, HxWxD 9.41x2.76x6.34 in, Module

ABB Low Voltage Drives ACS355-01U-02A4-2 ACS355 AC Drive, 1-200-240V In, 0.5HP, 2.4A, Type OPEN, 1.5 overload, Blank, HxWxD…

Alternate Item Number: 3AUA0000058196

UPC: 662348004050


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB ACS355-01U-02A4-2 AC drive (SKU: ACS355-01U-02A4-2) from ABB Low Voltage Drives is engineered for precise motor control in pump and fan applications, specifically designed for minimal overload demand. This open-type drive delivers a 0.5HP (370W) output with a 2.4A current rating, operating on a 1-200-240V input voltage, making it an ideal choice for standard 230V single-phase systems. Its 1.5 overload factor ensures reliable performance, capable of handling intermittent peak loads common in HVAC and water management systems without requiring derating. Designed with blank control options, the ACS355-01U-02A4-2 simplifies configuration for straightforward deployment. This drive is built for continuous operation in industrial settings where space efficiency and operational reliability are paramount. It offers a space-saving alternative to larger, bulkier drive units, compatible with standard 3-phase motors up to 0.5HP. A key benefit is that no external braking resistor is typically required for standard pump and fan duty cycles, further reducing installation complexity and cost. UNSPSC Code: 39122001. Country of Origin: DK.
  • ABB ACS355 AC Drive, SKU: ACS355-01U-02A4-2
  • 0.5HP (370W) motor output, 2.4A current rating
  • 1-200-240V input voltage, ideal for 230V systems
  • Open type, pump/fan optimized with 1.5 overload factor

Specifications

0.5
HP
1-Phase
A
2.4
A
2.6
lb
2.76
in
200-240
VAC
240
VAC
6.34
in
9.41
in
Amerage
2.4 A
Control Panel
Blank
Current Rating
2.4 A
Frame Size
R0
Height
9.41 in
Horsepower
0.5 HP
Horsepower 10% & 50% Overload/ 1 min
0.5 HP
Input Phase
1-Phase
IP Rating
IP20
Length
6.34 in
Mounting
Module
Number of Phases Input
1
Number of Phases Output
3
Output Current
2.4 A
Output Current 10% & 50% Overload/ 1 min
2.4 A
Output Phase
3-Phase
Phases
1-Phase A
Poles
1-Phase
Series
ACS355
Size
9.41x2.76x6.34 in
Type
ACS355 Drive
UL Type
OPEN
Voltage
240 V
Voltage Range
200-240 V
Voltage Rating
240 Vac
Voltage Rating
200-240 VAC
Weight
2.6 lb
Width
2.76 IN
Package Dimensions (L x W x H)
6.34 IN x 2.76 IN x 9.41 IN
Package Dimensions (L x W x H)
16.1036 cm x 7.0104 cm x 23.9014 cm
Package Weight (Imperial)
2.600 L
Package Weight (Metric)
1.179 kg
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What are the available AC supply voltage and power ranges?

It supports 1-phase (200-240V, 0.37-2.2kW), 3-phase (200-240V, 0.37-11kW), and 3-phase (380-480V, 0.37-22kW).

What are the dimensions of the ACS355-01U-02A4-2 model?

The ACS355-01U-02A4-2 model has dimensions of 8.0 in height, 2.8 in width, and 6.3 in depth.

What are the operating temperature limits for this drive?

The drive operates between 14 to 104°F (-10 to 40°C), with a 10% derating at 122°F (50°C). Frost is not allowed.

What is the overload capacity of the drive?

The drive has an overload capacity of 1.5 x I2N for 1 minute every 10 minutes, and 1.8 x I2N for 2 seconds at start.

What is the maximum relative humidity for operation?

The relative humidity must be lower than 95%, without condensation.

What is the Safe Torque Off function rating?

The Safe Torque Off function is rated SIL 3 and is included as standard.

Can this drive be preconfigured without power?

Yes, the FlashDrop tool allows for fast pre-configuration in seconds without powering the drive.

What types of motor control does the drive offer?

It offers sensorless vector control and can control both permanent magnet and induction motors.

What is the maximum current rating for the relay output?

The relay output has a maximum rating of 250 V AC/2 A or 30 V DC/0.5 A.

What are the available protection classes for demanding environments?

High protection class variants are available in IP66/IP67/UL Type 4X classes, which are NSF certified.