ABB Low Voltage Drives ACS355-01U-02A4-2 ACS355 AC Drive, 1-200-240V In, 0.5HP, 2.4A, Type OPEN, 1.5 overload, Blank, HxWxD…
Alternate Item Number: 3AUA0000058196
UPC: 662348004050
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- ABB ACS355 AC Drive, SKU: ACS355-01U-02A4-2
- 0.5HP (370W) motor output, 2.4A current rating
- 1-200-240V input voltage, ideal for 230V systems
- Open type, pump/fan optimized with 1.5 overload factor
Specifications
0.5 | HP |
1-Phase | A |
2.4 | A |
2.6 | lb |
2.76 | in |
200-240 | VAC |
240 | VAC |
6.34 | in |
9.41 | in |
Amerage | 2.4 A |
Control Panel | Blank |
Current Rating | 2.4 A |
Frame Size | R0 |
Height | 9.41 in |
Horsepower | 0.5 HP |
Horsepower 10% & 50% Overload/ 1 min | 0.5 HP |
Input Phase | 1-Phase |
IP Rating | IP20 |
Length | 6.34 in |
Mounting | Module |
Number of Phases Input | 1 |
Number of Phases Output | 3 |
Output Current | 2.4 A |
Output Current 10% & 50% Overload/ 1 min | 2.4 A |
Output Phase | 3-Phase |
Phases | 1-Phase A |
Poles | 1-Phase |
Series | ACS355 |
Size | 9.41x2.76x6.34 in |
Type | ACS355 Drive |
UL Type | OPEN |
Voltage | 240 V |
Voltage Range | 200-240 V |
Voltage Rating | 240 Vac |
Voltage Rating | 200-240 VAC |
Weight | 2.6 lb |
Width | 2.76 IN |
Package Dimensions (L x W x H) | 6.34 IN x 2.76 IN x 9.41 IN |
Package Dimensions (L x W x H) | 16.1036 cm x 7.0104 cm x 23.9014 cm |
Package Weight (Imperial) | 2.600 L |
Package Weight (Metric) | 1.179 kg |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What are the available AC supply voltage and power ranges?
It supports 1-phase (200-240V, 0.37-2.2kW), 3-phase (200-240V, 0.37-11kW), and 3-phase (380-480V, 0.37-22kW).
What are the dimensions of the ACS355-01U-02A4-2 model?
The ACS355-01U-02A4-2 model has dimensions of 8.0 in height, 2.8 in width, and 6.3 in depth.
What are the operating temperature limits for this drive?
The drive operates between 14 to 104°F (-10 to 40°C), with a 10% derating at 122°F (50°C). Frost is not allowed.
What is the overload capacity of the drive?
The drive has an overload capacity of 1.5 x I2N for 1 minute every 10 minutes, and 1.8 x I2N for 2 seconds at start.
What is the maximum relative humidity for operation?
The relative humidity must be lower than 95%, without condensation.
What is the Safe Torque Off function rating?
The Safe Torque Off function is rated SIL 3 and is included as standard.
Can this drive be preconfigured without power?
Yes, the FlashDrop tool allows for fast pre-configuration in seconds without powering the drive.
What types of motor control does the drive offer?
It offers sensorless vector control and can control both permanent magnet and induction motors.
What is the maximum current rating for the relay output?
The relay output has a maximum rating of 250 V AC/2 A or 30 V DC/0.5 A.
What are the available protection classes for demanding environments?
High protection class variants are available in IP66/IP67/UL Type 4X classes, which are NSF certified.