Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ABB-48431-362 - Braking Resistor, 1.8 OHMS, 32805 WATTS, ED3 Enclosure, 30W x 18D x 24H in, 169 lbs

ABB Low Voltage Drives ABB-48431-362 Braking Resistor, 1.8 OHMS, 32805 WATTS, ED3 Enclosure, 30W x 18D x 24H in, 169 lbs

Alternate Item Number: 3AUA0000015413

UPC: 662348001967


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Braking Resistor, SKU ABB-48431-362, is engineered for precise motor braking control in industrial settings. This unit features a 1.8 OHM resistance and a substantial 32805 WATTS power rating, ensuring efficient dissipation of braking energy. This capability is crucial for protecting variable frequency drives (VFDs) from overvoltage transients during deceleration, thereby safeguarding drive systems and promoting smooth operational transitions. The resistor is housed within a robust ED3 enclosure, providing essential protection against environmental factors common in industrial facilities. Its physical dimensions are 30 inches wide, 18 inches deep, and 24 inches high, with a weight of 169 lbs. Designed for reliability and longevity, this braking resistor is an ideal complement to ABB Low Voltage Drives, enhancing overall system performance and contributing to extended equipment lifespan. Manufactured in the US, it adheres to high standards for power and automation components. This resistor is classified under UNSPSC code 39122004.
  • 1.8 OHM resistance for effective braking
  • 32805 WATTS power rating for high energy dissipation
  • ED3 enclosure for industrial environment protection
  • Dimensions: 30W x 18D x 24H inches
  • Designed for use with ABB Low Voltage Drives
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
HMI door mounting kit with 2M cable

181B0399

HMI door mounting kit with 2M cable
CONDUIT MODULE B(LSLV-S100),DFR2-S100

64150005

CONDUIT MODULE B(LSLV-S100),DFR2-S100
FAN POWER SUPPLY BOARD CFV1D.400V/48V

CFW11SP-12387920

FAN POWER SUPPLY BOARD CFV1D.400V/48V
Braking Resistor, 1.7 OHMS, 8330 WATTS, GCE12 Enclosure, 26.5W x 13D x 5H in, 45 lbs

ABB-48431-390

Braking Resistor, 1.7 OHMS, 8330 WATTS, GCE12 Enclosure, 26.5W x 13D x 5H in, 45 lbs
Braking Resistor, 1.8 OHMS, 40500 WATTS, ED4 Enclosure, 30W x 18D x 32H in, 191 lbs

ABB-48431-363

Braking Resistor, 1.8 OHMS, 40500 WATTS, ED4 Enclosure, 30W x 18D x 32H in, 191 lbs
Braking Resistor, 1.8 OHMS, 14580 WATTS, GCE24 Enclosure, 28W x 13D x 10H in, 76 lbs

ABB-48431-360

Braking Resistor, 1.8 OHMS, 14580 WATTS, GCE24 Enclosure, 28W x 13D x 10H in, 76 lbs
Interface cable for communication between the DCF external field supply and the DCS800 drive and/or between DCS800 drives. The cable supports communication for 12 pulse operation and drive-to-drive communication with the SDCS-DSL-4 board. This cable is 66 feet (20 m) long and has ferrule-tipped wires on both ends.

DCS800-DSL-20M-Cable

Interface cable for communication between the DCF external field supply and the DCS800 drive and/or between DCS800 drives. The cable supports communication for 12 pulse operation and drive-to-drive communication with the SDCS-DSL-4 board. This cable is 66 feet (20 m) long and has ferrule-tipped wires on both ends.

Frequently Asked Questions

What is the purpose of a braking resistor with variable frequency drives?

Braking resistors are required for applications needing faster deceleration or when motor speeds exceed synchronous speed, dissipating regenerated power to prevent bus voltage from exceeding drive limits.

What are the typical duty cycles for the listed resistors?

Duty cycles include 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.

What is the voltage range for ACS250 three-phase applications?

These drives are for three-phase 200-240V and 380-480V and 575-690V applications and are intended for stopping duty only.

What is the voltage range for ACS150 and ACS355 three-phase applications?

These drives are for three-phase 200-240V and 380-480V applications and are intended for stopping duty only.

What is the voltage range for ACS250 single-phase applications?

These drives are for single-phase 100-120V and 200-240V applications and are intended for stopping duty only.

What is the voltage range for ACS150 and ACS355 single-phase applications?

These drives are for single-phase 200-240V applications and are intended for stopping duty only.

How are Powerohm Type CR resistors constructed?

They feature a nickel-chromium wire coil inside a ceramic fixture, housed in an aluminum case. Coil ends connect to high-temperature wire leads and are encapsulated with ceramic potting material.

What is the purpose of braking choppers (modules)?

Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power, preventing over-voltage trips and improving drive system performance.

What is the purpose of an overhauling load condition?

An overhauling load condition occurs when motor speeds exceed the synchronous speed set by the drive's output frequency, causing regenerated power to flow back into the drive.

What wire type should be used when connecting directly to resistors in Type ED enclosures?

If installing without optional terminal connections, always use 200ºC rated silicone or Teflon wire when attaching directly to resistors.