ABB Low Voltage Drives ABB-48431-072 Braking Resistor, 11 OHMS, 15884 WATTS, GCE24 Enclosure, 28W x 13D x 10H in, 56 lbs
Alternate Item Number: 3AUA0000015319
UPC: 662348001288
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 11 OHM Resistance for effective braking
- 15884 WATTS Power Rating for high energy dissipation
- GCE24 Enclosure for industrial environmental protection
- Dimensions: 28"W x 13"D x 10"H
- Weight: 56 lbs, designed for durability
Frequently Asked Questions
What is the purpose of a braking resistor with a variable frequency drive?
A braking resistor is required for applications needing faster deceleration or when motor speeds exceed synchronous speed. It dissipates regenerated power to prevent bus voltage from exceeding the drive's rated limit.
When are braking modules used with variable frequency drives?
Braking modules are used when an application requires faster deceleration or when motor speeds exceed synchronous speed, creating regenerated power that raises the drive's DC bus voltage.
What are the available duty cycles for CR resistors with ACS150/355 drives?
Available duty cycles include 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.
What is the purpose of the braking resistor in overhauling load conditions?
In overhauling load conditions, the motor speed exceeds the synchronous speed, causing regenerated power to flow back into the drive. The braking resistor dissipates this power to prevent over-voltage trips.
How are Powerohm Type CR resistors constructed?
They feature a nickel-chromium wire coil inside a ceramic fixture, enclosed in a corrosion-resistant aluminum case. Coil ends are terminated to high-temperature wire leads and encapsulated with ceramic potting material.
What is the function of the thermal switch in GCE and ED enclosures?
A normally closed thermal switch is provided in both GCE and ED enclosures to detect resistor temperature overloads.
What is the voltage range for ACS150 and ACS355 single-phase applications?
The ACS150 and ACS355 drives are available for single-phase 200-240V applications.
What are the voltage ranges for ACS250 drives?
ACS250 drives are available for single-phase 100-120V and 200-240V applications, and three-phase 200-240V and 380-480V applications.
What is the standard voltage for ACS550 three-phase applications?
The ACS550 drives are available for three-phase 200-240V and 380-480V applications.
What are the installation features of Type GCE enclosures?
Type GCE enclosures have a solid bottom and a separate wiring compartment. They include a terminal block for factory-wired resistors and 1/2 inch conduit knockouts for routing wires.