ABB Low Voltage Drives ABB-44477 Braking Resistor, 8.14 OHMS, 6863 WATTS, GCE15 Enclosure, 26.5W x 16D x 5H in, 35 lbs
Alternate Item Number: 3AUA0000015214
UPC: 662348000588
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 8.14 ohm resistance for precise energy dissipation
- 6863 watt power rating for high-performance braking
- Compact dimensions: 26.5W x 16D x 5H inches, 35 lbs weight
- Compatible with ABB Low Voltage Drives for seamless integration
- Compatible with ABB Low Voltage Drives
Specifications
Size | 26.5W x 16D x 5H in |
Frequently Asked Questions
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors increase braking torque capability for faster, controlled braking and dissipate regenerated power to prevent bus voltage from exceeding drive limits.
What is the purpose of a braking module?
Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power and prevent over-voltage trips.
What wire is recommended for connecting to resistors if not using optional terminal connections?
If installing without optional terminal connections, use 200ºC rated silicone or Teflon wire when attaching directly to resistors.
What is the function of the thermal switch in Type GCE and ED enclosures?
The normally closed thermal switch detects resistor temperature overloads and is used to monitor for over-temperature conditions.
How are Powerohm Type CR resistors constructed?
They use nickel-chromium wire helically wound in a ceramic fixture, housed in an aluminum case with high-temperature wire leads and ceramic potting.
What wire is used for routing into the Type GCE conduit knockout?
Standard 90ºC rated wire is routed into the compartment through the removable 1/2 inch conduit knockouts.
What is the duty cycle for the listed resistor applications?
The duty cycles listed are 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.
What is the voltage range for ACS150 and ACS355 single-phase drives?
These drives are for single-phase 200-240V applications and are intended for stopping duty only.
What is the voltage range for ACS150 and ACS355 three-phase drives?
These drives are for three-phase 200-240V and 380-480V applications and are intended for stopping duty only.
What is the voltage range for ACS250 single-phase drives?
These drives are for single-phase 100-120V and 200-240V applications and are intended for stopping duty only.