ABB Low Voltage Drives ABB-44473 Braking Resistor, 13.5 OHMS, 2509 WATTS, GCE6 Enclosure, 19W x 10D x 5H in, 19 lbs
Alternate Item Number: 3AUA0000015210
UPC: 662348000540
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 13.5 OHM resistance for effective energy dissipation
- 2509 WATTS power rating for robust braking
- GCE6 enclosure for industrial protection
- Compact dimensions: 19" W x 10" D x 5" H
- Durable construction weighing 19 lbs
Specifications
Nema Rating | GCE6 Enclosure |
Size | 19W x 10D x 5H in |
Frequently Asked Questions
What is the voltage range for ACS150 and ACS355 single-phase applications?
These drives are for single-phase 200-240V applications and are designed for stopping duty only.
What is the voltage range for ACS150 and ACS355 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications and are designed for stopping duty only.
What is the voltage range for ACS250 single-phase applications?
These drives are for single-phase 100-120V and 200-240V applications and are designed for stopping duty only.
What is the voltage range for ACS250 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications and are designed for stopping duty only.
What is the voltage range for ACS550 three-phase applications?
These drives are for three-phase 200-240V and 380-480V applications and are designed for stopping duty only.
What is the purpose of a braking resistor with variable frequency drives?
Braking resistors are used to dissipate regenerated power, preventing bus voltage from exceeding the drive's rated limit, especially during faster deceleration or overhauling load conditions.
What is the function of the thermal switch in Type GCE and ED enclosures?
The normally closed thermal switch detects resistor temperature overloads, providing a safety mechanism to prevent overheating.
What is the purpose of a braking chopper module?
Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power and improve system performance.
What are the typical duty cycles mentioned for the resistors?
The duty cycles mentioned are 3sec on/27sec off, 10sec on/50sec off, 30sec on/180sec off, and 60sec on/180sec off.
What is the purpose of braking resistors in overhauling load conditions?
In overhauling load conditions, braking resistors dissipate regenerated power to prevent the bus voltage from exceeding the drive's rated limit.