ABB Low Voltage Drives ABB-41150 Braking Resistor, 4 OHMS, 5600 WATTS, GCE9 Enclosure, 26.5W x 10D x 5H in, 26 lbs
Alternate Item Number: 3AUA0000015136
UPC: 662348000236
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 4 Ohm resistance for precise braking torque control
- 5600 Watt power rating for high-energy dissipation
- GCE9 enclosure for robust protection in industrial environments
- Compact dimensions: 26.5W x 10D x 5H inches, 26 lbs weight
- Compatible with ABB ACS800-PC/U7 series drives
Specifications
Size | 26.5W x 10D x 5H in |
Frequently Asked Questions
What is the resistance and wattage for a 5 Hp ACS150/355-03U- drive with a 60sec on/180sec off duty cycle?
For a 5 Hp ACS150/355-03U- drive with a 60sec on/180sec off duty cycle, the enclosed resistor package is 35 Ohms and 820 Watts.
What is the resistance and wattage for a 3 Hp ACS250-03U- drive (UL Type 4X) with a 30sec on/180sec off duty cycle?
For a 3 Hp ACS250-03U- drive (UL Type 4X) with a 30sec on/180sec off duty cycle, the enclosed resistor package is 35 Ohms and 820 Watts.
What is the resistance and wattage for a 10 Hp ACS250-03U- drive (575-690V) with a 60sec on/180sec off duty cycle?
For a 10 Hp ACS250-03U- drive (575-690V) with a 60sec on/180sec off duty cycle, the enclosed resistor package is 63 Ohms and 1200 Watts.
What is the resistance and wattage for a 20 Hp ACS550-U1- drive (200-240V) with a 60sec on/180sec off duty cycle?
For a 20 Hp ACS550-U1- drive (200-240V) with a 60sec on/180sec off duty cycle, the enclosed resistor package is 5.3 Ohms and 4770 Watts.
What are the resistance and wattage for a 3 Hp ACS150/355-01U- drive with a 10sec on/50sec off duty cycle?
For a 3 Hp ACS150/355-01U- drive with a 10sec on/50sec off duty cycle, the Type CR resistor is 50 Ohms and 300 Watts.
What is the purpose of a braking resistor with variable frequency drives?
A braking resistor is required for applications needing faster deceleration or to manage overhauling load conditions. It dissipates regenerated power to prevent bus voltage from exceeding the drive's rated limit.
What is the role of Braking Modules with AC drives?
Braking Modules monitor the drive's DC bus and activate external braking resistors as needed. This manages regenerated power, prevents over-voltage trips, and improves drive system performance.
What wire rating is required for direct connection to resistors in Type ED enclosures?
If installing without optional terminal connections, always use 200ºC rated silicone or Teflon wire when attaching directly to resistors.
What is the function of the thermal switch in Type GCE and ED enclosures?
A normally closed thermal switch is provided to detect resistor temperature overloads. This helps prevent damage by monitoring the operating temperature.
What wire rating is needed for Type GCE enclosure wiring?
Standard 90ºC rated wire is used when routed into the compartment through the removable 1/2 inch conduit knockouts and connected to the factory wired terminal block.