Contact for Pricing
Minimum Qty: 5
Multiplier: 5
*Contact for lower quantities*
Overview
- Concrete-tight design prevents moisture and debris ingress
- Constructed from durable steel for high corrosion resistance
- Compatible with 2-1/2 inch EMT conduit
- 3.428 inch length for secure installation
- Meets industry standards for electrical safety and conduit fittings
Specifications
Application | For use with EMT Conduit |
Finish | Zinc Plated |
Material | Steel |
Material Quality | Steel |
Series | TC117US |
Size | 2-1/2 Inches |
Special Features | Steel construction for strength and durability |
Standard | UL E16592 |
Type | EMT Conduit Fittings |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.330 L |
Package Weight (Metric) | 1.057 kg |

TC129A
Set Screw Connector, Concrete Tight, Conduit Size 3-1/2 Inches, Length 3.906 Inches, Material Zinc Plated Steel, For use with EMT Conduit
TC115US
Compression Connector, Concrete Tight, Conduit Size 1-1/2 Inch, Length 1.553 Inches, Material Steel, For use with EMT Conduit
TC114US
Compression Connector, Concrete Tight, Conduit Size 1-1/4 Inch, 1.317 Inches, Material Steel, For use with EMT Conduit
TC116US
Compression Connector, Concrete Tight, Conduit Size 2 Inches, Length 1.614 Inches, Material Steel, For use with EMT Conduit
TC112US
Compression Connector, Concrete Tight, Conduit Size 3/4 Inch, Length 1.065 Inches, Material Steel, For use with EMT Conduit
TC111US
Compression Connector, Concrete Tight,Concrete Tight, Conduit Size 1/2 Inch, Length 1.028 Inches, Material Steel, For use with EMT Conduit
TC113US
Compression Connector, Concrete Tight, Conduit Size 1 Inch, Length 1.170 Inches, Material Steel, For use with EMT ConduitFrequently Asked Questions
When is a sealing ring required for installation?
A sealing ring is required when the fitting is used outside, on the top, and on the sides of an enclosure.
Can compliance be visually inspected from a distance?
Yes, the distinctive design and vibrant gold gland nut allow inspectors to visually check compliance from a distance without close-up inspection.
How are fire alarm fittings identified?
Fire alarm fittings are painted red for clear identification as Fire Alarm (FA) components.
What is the recommended installation torque?
The recommended installation torque is 15 in-lb onto the EMT. Excessive torque may damage the EMT or housing.
What certifications do these fittings have?
The fittings are UL Listed and CSA certified, ensuring they meet recognized safety and performance standards.
What is the primary application of these fittings?
These fittings are primarily designed for use with Electrical Metallic Tubing (EMT).
What is the recommended installation torque?
The recommended installation torque is 15 in-lb onto the EMT. Excessive torque may damage the EMT or housing.
What is the primary application of these fittings?
These fittings are primarily designed for use with Electrical Metallic Tubing (EMT).
What certifications do these fittings have?
The fittings are UL Listed and CSA certified, ensuring they meet recognized safety and performance standards.
How are fire alarm fittings identified?
Fire alarm fittings are painted red for clear identification as Fire Alarm (FA) components.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.