Authorized ABB Distributor (Installation Products)
ABB - Installation Products LTZES01G-C - Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 3/8 Inch, Length 30 Meters/100 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

ABB Installation Products LTZES01G-C Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit…

UPC: 786210113210


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 3000

Multiplier: 3000

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Liquid Tight Flexible Metallic Conduit (SKU: LTZES01G-C) provides robust protection for electrical wiring in industrial settings. Constructed with a galvanized steel core and an outer PVC jacket, it offers reliable mechanical strength and resistance to environmental factors. The conduit is rated for a working temperature range of -40 to 80 degrees Celsius, ensuring consistent performance across various conditions. Its 3/8-inch trade size and 100-foot (30-meter) length provide ample coverage for installation projects. Key features include its halogen-free composition and compliance with RoHS regulations, making it suitable for applications where fire safety and environmental impact are critical considerations. The gray PVC jacket offers good abrasion resistance and seals against liquids and dust, fulfilling its liquid-tight designation. This conduit is ideal for protecting cables in machine tools, automation equipment, and general industrial wiring where flexibility and durable protection are required. ABB Installation Products is a trusted manufacturer in this sector, ensuring product reliability.
  • Galvanised steel core with gray PVC jacket for durability
  • 3/8 Inch trade size, 100 Feet (30 Meters) length
  • Halogen free and RoHS compliant for safety and environmental standards
  • Working temperature range: -40 to 80 Degrees C
  • Liquid-tight protection against dust and moisture

Specifications

Color
Gray
Declaration of Conformity - CE
9AKK107492A9900
Finish
PVC Jacket
Inside Diameter
0.484 in
Inside Diameter
12.2936 mm
Length
1200 in
Length
30000 mm
Material Quality
Galvanized Steel Core
Outside Diameter
0.71 in
Outside Diameter
18.034 mm
Standard
RoHS
Trade Size
3/8 in , 16 mm
Type
Liquid Tight Flexible Metallic Conduit
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.2000 L
Package Weight (Metric)
0.0910 kg
3/8 Inch Gray Liquidtight Flexible Non-metallic Conduit, 1,000 Foot Reel

15004-001

3/8 Inch Gray Liquidtight Flexible Non-metallic Conduit, 1,000 Foot Reel
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 3 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

LTZES09G-A

Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 3 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

LTZES08G-A

Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 4 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

LTZES11G-A

Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 4 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 5 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

LTZES12G-A

Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 5 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 6 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

LTZES13G-A

Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 6 Inch, Length 8 Meters/25 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

LTZES02G-K

Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

LTZES03G-K

Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Halogen Free, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Gray

Frequently Asked Questions

How does 10W-40 motor oil affect the LTXE jacket?

After 72 hours at 100 °C exposure to 10W-40 motor oil, the LTXE jacket's tensile strength is 50%, elongation is 55%, and volume increase is 25%.

What do the chemical resistance ratings A, B, C, D mean?

The ratings indicate: A - Excellent to Good, B - Good to Fair, C - Fair to Limited, and D - Unsatisfactory resistance.

Is the chemical resistance information a guarantee?

No, this information is provided as a guideline only, and no guarantee is implied.

What is recommended for extreme chemical exposure situations?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations.

How does ASTM #2 Oil affect LTXE jacket tensile strength?

After 7 days at 60 °C, tensile strength is 90%; after 4 days at 100 °C, it is 66%; and after 18 hours at 120 °C, it is 45%.

What is the LTXE jacket's elongation after Ethylene Glycol exposure?

After 72 hours at 100 °C exposure to Ethylene Glycol, the LTXE jacket's elongation is 90%.

Does Silicon Oil cause volume change in the LTXE jacket?

Yes, after 72 hours at 100 °C exposure to Silicon Oil, the LTXE jacket shows a -14% volume increase.

How does Gasoline affect the LTXE jacket?

After 72 hours at 100 °C exposure to Gasoline, the LTXE jacket's tensile strength is 40%, elongation is 35%, and volume increase is 17%.

What is the volume increase for LTXE jacket with Transmission Oil?

After 72 hours at 100 °C exposure to Transmission Oil, the LTXE jacket experiences a 32% volume increase.

How does Freon2 affect the LTXE jacket's properties?

After 72 hours at 80 °C exposure to Freon2, the LTXE jacket retains 93% tensile strength and 84% elongation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.