Authorized ABB Distributor (Installation Products)
ABB - Installation Products LTXES04B-J - Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1 Inch, Length 120 Meters/400 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

ABB Installation Products LTXES04B-J Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core…

UPC: 786210107349


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 1600

Multiplier: 1600

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB LTXES04B-J Liquid Tight Flexible Metallic Conduit is engineered for exceptional performance in extreme temperature conditions. Constructed with a galvanized steel core and a robust TPR (Thermoplastic Rubber) jacket, this conduit provides reliable protection for electrical wiring in environments ranging from -60°C to 150°C. It can withstand intermittent temperatures up to 165°C, making it suitable for applications where significant thermal fluctuations are expected. This conduit meets RoHS compliance, ensuring it adheres to environmental standards for hazardous substances. The black TPR jacket offers excellent resistance and flexibility, while the 1-inch trade size and 120-meter (400 feet) length provide ample material for extensive installations. The liquid-tight design ensures that internal wiring is protected from moisture, dust, and other contaminants, crucial for maintaining operational integrity in harsh industrial settings. Key Specifications: - SKU: LTXES04B-J - Manufacturer: ABB - Installation Products - Conduit Size: 1 Inch - Length: 120 Meters / 400 Feet - Working Temperature: -60°C to 150°C - Intermittent Temperature: Up to 165°C - Material: Galvanised Steel Core with TPR Jacket - Compliance: RoHS - Color: Black
  • Extreme temperature range: -60°C to 150°C working, 165°C intermittent.
  • Durable construction: Galvanised steel core with a black TPR jacket.
  • Liquid-tight protection: Shields wiring from moisture and contaminants.
  • RoHS compliant: Meets environmental standards for hazardous substances.
  • 1-inch trade size, 120 meters (400 feet) length for extensive installations.

Specifications

Application
Used in extremely high temperature applications such as commercial ovens and refrigeration, industrial furnaces and foundries
Color
Black
Declaration of Conformity - CE
9AKK107492A9892
Finish
TPR Jacket
Inside Diameter
1.041 in
Inside Diameter
26.4414 mm
Length
4800 in
Length
120000 mm
Material
Galvanised Steel Core with TPR Jacket
Material Quality
Galvanised Steel
Outside Diameter
1.315 in
Outside Diameter
33.401 mm
Radius
2.9921 in
Radius
76 mm
Series
LTXES
Size
1 Inch
Special Features
Designed to meet UL 360 ID/OD dimension requirements
Standard
RoHS
Trade Size
1 in
Type
Liquid Tight Flexible Metallic Conduit
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.5600 L
Package Weight (Metric)
0.2540 kg
Liquid Tight, High Temperature Conduit, Nominal Conduit Size 32mm, 1 Inch US Trade Size, Outside Diameter 33.1mm, Inside Diameter 26.7mm, Static Bend Radius 145mm, Reel Length 20 Meters, IP66, IP67 Ratings, Stainless Steel AISI 316L Core, String Packing with Thermoplastic Rubber Covering, Black

FSH0620

Liquid Tight, High Temperature Conduit, Nominal Conduit Size 32mm, 1 Inch US Trade Size, Outside Diameter 33.1mm, Inside Diameter 26.7mm, Static Bend Radius 145mm, Reel Length 20 Meters, IP66, IP67 Ratings, Stainless Steel AISI 316L Core, String Packing with Thermoplastic Rubber Covering, Black
Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1-1/4 Inch, Length 60 Meters/200 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

LTXES05B-E

Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1-1/4 Inch, Length 60 Meters/200 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

LTXES08B-A

Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

LTXES03B-K

Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

LTXES02B-K

Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

LTXES06B-D

Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 3/8 Inch, Length 300 Meters/1,000 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

LTXES01B-L

Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 3/8 Inch, Length 300 Meters/1,000 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1/2 Inch, Length 300 Meters/1,000 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

LTXES02B-L

Liquid Tight Flexible Metallic Conduit, Extreme Temperature Range, Galvanised Steel Core with TPR Jacket, Conduit Size 1/2 Inch, Length 300 Meters/1,000 Feet, Working Temperature -60 to 150 Degrees C, Intermitting to 165 Degrees C, Compliant to RoHS, Black

Frequently Asked Questions

What is the purpose of this chemical resistance guide?

This guide provides information on the chemical resistance of flexible metallic conduit components, specifically PVC, PU, and Type LTXE thermoplastic rubber jackets. It helps determine compatibility with various chemicals.

How is chemical resistance rated for PVC and PU?

Chemical resistance for PVC and PU is rated using a scale: A (Excellent to Good), B (Good to Fair), C (Fair to Limited), and D (Unsatisfactory).

Is the chemical resistance data guaranteed for all applications?

No, the information is a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests, not installed end-product applications.

What is the LTXE jacket's resistance to 5% Salt Water?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 80% tensile strength and 100% elongation, with a 1% volume increase.

How does the LTXE jacket perform with Silicon Oil?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 100% tensile strength and 80% elongation, with a -14% volume increase.

What is the resistance of PVC to Carbon Tetrachloride?

PVC has a "D" rating (Unsatisfactory) for resistance to Carbon Tetrachloride.

What is the resistance of PU to Sulfuric Acid 98%?

PU has a "D" rating (Unsatisfactory) for resistance to Sulfuric Acid 98%.

What is recommended for extreme chemical exposure situations?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations to verify chemical resistance.

How does the LTXE thermoplastic rubber jacket resist ASTM #2 Oil?

After 7 days at 60 °C, the LTXE jacket retains 90% tensile strength and 98% elongation. At 100 °C for 4 days, it retains 66% tensile strength and 70% elongation.

What is the LTXE jacket's resistance to gasoline?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 40% tensile strength and 35% elongation, with a 17% volume increase.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.