Authorized ABB Distributor (Installation Products)
ABB - Installation Products LTMES02B-K - Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black

ABB Installation Products LTMES02B-K Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 1/2…

UPC: 786210154039


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 1000

Multiplier: 1000

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products LTMES02B-K Liquid Tight Flexible Metallic Conduit (LTFMC) provides reliable mechanical protection for electrical wiring in harsh industrial environments. This 1/2-inch conduit features a bronze core for durability and a PVC jacket for liquid tightness, ensuring continuous performance in wet, dusty, or corrosive conditions. The 150-meter (500-foot) length offers efficient installation with minimal joints, reducing labor costs and potential leak points. Designed for EMC mid-performance applications, it meets RoHS and WEEE directives, making it suitable for environmentally regulated installations. The halogen-free construction enhances safety in enclosed spaces by minimizing toxic gas emissions during fire events. With a working temperature range of -55°C to 105°C, this conduit maintains flexibility and integrity in extreme thermal conditions, from arctic installations to high-heat industrial zones. Ideal for machine tool wiring, control panels, and outdoor enclosures where vibration resistance and EMI shielding are required. Compliance with industry standards ensures reliable operation in commercial and industrial electrical systems.
  • Bronze core for mechanical strength and EMI shielding
  • PVC jacket provides liquid tightness and corrosion resistance
  • 150m (500ft) length reduces installation joints and labor
  • Halogen-free construction for fire safety in enclosed spaces
  • Operates from -55°C to 105°C for extreme environment use

Specifications

Color
Black
Declaration of Conformity - CE
9AKK107492A9898
Length
175 in
Length
4445 mm
Material Quality
Bronze Core with PVC Jacket
Standard
Compliant to RoHS and WEEE
Trade Size
1/2 in
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.3500 L
Package Weight (Metric)
0.1590 kg
1/2 Inch Black Liquidtight Flexible Non-metallic Conduit, 100 Foot Coil

15005BK-100

1/2 Inch Black Liquidtight Flexible Non-metallic Conduit, 100 Foot Coil
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 3/8 Inch, Length 300 Meters/1,000 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black

LTMES01B-L

Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 3/8 Inch, Length 300 Meters/1,000 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 1/2 Inch, Length 300 Meters/1,000 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black

LTMES02B-L

Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 1/2 Inch, Length 300 Meters/1,000 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray

CLGES02G-K

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel with PVC Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray

CLGES03G-K

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel with PVC Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel with PVC Jacket, Conduit Size 1-1/4 Inch, Length 15 Meters/50 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray

CLGES05G-B

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel with PVC Jacket, Conduit Size 1-1/4 Inch, Length 15 Meters/50 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray
Flexible Metallic Conduit, Heavy Gauge Aluminum Alloy, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, UL, CSA, Compliant to RoHS, Metallic

CMACS02M-K

Flexible Metallic Conduit, Heavy Gauge Aluminum Alloy, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, UL, CSA, Compliant to RoHS, Metallic
Flexible Metallic Conduit, Heavy Gauge Aluminum Alloy, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, UL, CSA, Compliant to RoHS, Metallic

CMACS02M-C

Flexible Metallic Conduit, Heavy Gauge Aluminum Alloy, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, UL, CSA, Compliant to RoHS, Metallic

Frequently Asked Questions

What is the chemical resistance rating system?

The chemical resistance is rated as A (Excellent to Good), B (Good to Fair), C (Fair to Limited), and D (Unsatisfactory).

What materials are covered in the chemical resistance guide?

The guide covers Polyvinyl Chloride (PVC) and Polyurethane (PU) for flexible metallic conduit, and Type LTXE thermoplastic rubber for its jacket.

Is the chemical resistance information guaranteed?

No, this information is provided as a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests.

How should chemical resistance be verified for extreme conditions?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations.

How should chemical resistance be verified for extreme conditions?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations.

Is the chemical resistance information guaranteed?

No, this information is provided as a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests.

What materials are covered in the chemical resistance guide?

The guide covers Polyvinyl Chloride (PVC) and Polyurethane (PU) for flexible metallic conduit, and Type LTXE thermoplastic rubber for its jacket.

What is the chemical resistance rating system?

The chemical resistance is rated as A (Excellent to Good), B (Good to Fair), C (Fair to Limited), and D (Unsatisfactory).

What materials are covered in the chemical resistance guide?

The guide covers Polyvinyl Chloride (PVC) and Polyurethane (PU) for flexible metallic conduit, and Type LTXE thermoplastic rubber for its jacket.

Is the chemical resistance information guaranteed?

No, this information is provided as a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.