Contact for Pricing
Minimum Qty: 25
Multiplier: 25
*Contact for lower quantities*
Overview
- 4" trade size (100mm) with fully interlocked design for 2-1/2" to 4" sizes
- Galvanized steel core for crush resistance and grounding continuity
- Smooth extruded PVC jacket for liquid-tight performance against water, oils, and mild acids
- Operating temperature range: -40°C to 75°C
- IP65 ingress protection rating per IEC 60529
Specifications
Application | For use to CEC as described in Section 12-1300 for dry damp or wet locations where flexibility is required |
Color | Black |
Declaration of Conformity - CE | 9AKK107492A9893 |
Finish | PVC Jacket |
Inside Diameter | 4 in |
Inside Diameter | 101.6 mm |
Length | 300 in |
Length | 8000 mm |
Material | Galvanized Steel Core with PVC Jacket |
Material Quality | Galvanised Steel |
Outside Diameter | 4.5 in |
Outside Diameter | 114.3 mm |
Radius | 24.0157 in |
Radius | 610 mm |
Series | LTGCS |
Size | 4 Inch |
Special Features | Designed to meet CSA C22.2 No. 56 ID/OD dimension requirements |
Standard | CSA, RoHS |
Trade Size | 4 in |
Type | Liquid Tight Flexible Metallic Conduit |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 5.0400 L |
Package Weight (Metric) | 2.2860 kg |

LTZUS11B-A
Liquid Tight Flexible Metallic Conduit, Galvanised Steel Core with PVC Jacket, Conduit Size 4 Inch, Length 8 Meters/25 Feet, Halogen Free, UL 360, CSA, Compliant to RoHS, Working Temperature -40 to 80 Degrees C, Black
LTGCS02B-K
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 150 Meters/500 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGCS02B-L
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 300 Meters/1,000 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGCS06B-D
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 45 Meters/150 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGCS05B-E
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 1-1/4 Inch, Length 60 Meters/200 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGCS07B-C
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 30 Meters/100 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGCS03B-L
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 300 Meters/1,000 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGUS07G-B
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 2 Inch, Length 15 Meters/50 Feet, Working Temperature -30 to 80 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, GrayFrequently Asked Questions
What is the purpose of this chemical resistance guide?
This guide provides information on the chemical resistance of flexible metallic conduit components, specifically PVC, PU, and Type LTXE thermoplastic rubber jackets. It helps determine compatibility with various chemicals.
How is chemical resistance rated for PVC and PU?
Chemical resistance for PVC and PU is rated using a scale: A (Excellent to Good), B (Good to Fair), C (Fair to Limited), and D (Unsatisfactory).
Is the chemical resistance data guaranteed for all applications?
No, the information is a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests, not installed end-product applications.
What is the resistance of PU to Acetone?
PU has a "D" rating (Unsatisfactory) for resistance to Acetone.
Is the LTXE jacket resistant to Freon2?
After 72 hours at 80 °C, the LTXE thermoplastic rubber jacket retains 93% tensile strength and 84% elongation when exposed to Freon2.
What is the LTXE jacket's resistance to 5% Salt Water?
After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 80% tensile strength and 100% elongation, with a 1% volume increase.
How does the LTXE jacket perform with Silicon Oil?
After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 100% tensile strength and 80% elongation, with a -14% volume increase.
What is the resistance of PVC to Carbon Tetrachloride?
PVC has a "D" rating (Unsatisfactory) for resistance to Carbon Tetrachloride.
What is the resistance of PU to Sulfuric Acid 98%?
PU has a "D" rating (Unsatisfactory) for resistance to Sulfuric Acid 98%.
What is recommended for extreme chemical exposure situations?
ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations to verify chemical resistance.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.