ABB - Installation Products LTGCS05B-B - Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 1-1/4 Inch, Length 15 Meters/50 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
ABB - Installation Products

LTGCS05B-B

UPC: 786210107523


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 50

Multiplier: 50

*Contact for lower quantities*

Overview

The ABB LTGCS05B-B is a general-purpose liquid-tight flexible metallic conduit designed for reliable cable protection. Constructed with a galvanized steel core and an outer PVC jacket, this conduit offers robust mechanical strength and effective sealing against liquids. Its flexible nature allows for easy routing in complex installations, while the durable construction ensures long-term performance in various industrial settings. This specific model features a 1-1/4 inch trade size and comes in a convenient 15-meter (50-foot) length, finished in black for discreet installation. Operating within a temperature range of -40 to 75 degrees Celsius, it is suitable for environments with moderate temperature fluctuations. Certified by CSA for heavy-duty applications (LR-72635), it meets stringent safety and performance standards. Furthermore, the ABB LTGCS05B-B is compliant with RoHS regulations, indicating its adherence to environmental material restrictions. This conduit is an effective solution for protecting electrical wiring from physical damage and liquid ingress in general industrial applications. Key specifications include: SKU: LTGCS05B-B, Manufacturer: ABB - Installation Products, Conduit Size: 1-1/4 Inch, Length: 15 Meters/50 Feet, Working Temperature: -40 to 75 Degrees C, Certifications: CSA heavy duty LR-72635, RoHS Compliant, Color: Black.
  • General Purpose Liquid-Tight Flexible Metallic Conduit
  • Galvanized Steel Core with Durable PVC Jacket
  • 1-1/4 Inch Trade Size, 15 Meters (50 Feet) Length
  • Operating Temperature: -40 to 75 Degrees C
  • CSA Heavy Duty Certified (LR-72635) and RoHS Compliant

Specifications

Application
For use to CEC as described in Section 12-1300 for dry damp or wet locations where flexibility is required
Color
Black
Declaration of Conformity - CE
9AKK107492A9893
Finish
PVC Jacket
Inside Diameter
1.38 in
Inside Diameter
35.052 mm
Length
600 in
Length
15000 mm
Material Quality
Galvanised Steel
Outside Diameter
1.66 in
Outside Diameter
42.164 mm
Radius
7.9921 in
Radius
203 mm
Special Features
Designed to meet CSA C22.2 No. 56 ID/OD dimension requirements
Standard
CSA, RoHS
Trade Size
1-1/4 in
Type
Liquid Tight Flexible Metallic Conduit
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.8600 L
Package Weight (Metric)
0.3900 kg
1-1/4 Inch Black Non-metallic Conduit, 100 Foot Coil

15109-100

1-1/4 Inch Black Non-metallic Conduit, 100 Foot Coil
Liquid Tight Flexible Metallic Conduit, Aluminum Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray

LTAES02G-C

Liquid Tight Flexible Metallic Conduit, Aluminum Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -30 to 80 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTGUS03B-C

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -30 to 80 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Working Temperature -30 to 80 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTGUS08B-A

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Working Temperature -30 to 80 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -30 to 80 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black

LTGUS02B-C

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -30 to 80 Degrees C, UL E125517, CSA LR-72635, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Black

LTGES02B-C

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 1/2 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Black

LTGES03B-C

Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanised Steel Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Black
Liquid Tight Flexible Metallic Conduit, Aluminum Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray

LTAES03G-C

Liquid Tight Flexible Metallic Conduit, Aluminum Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS, Gray

Frequently Asked Questions

What is the purpose of this chemical resistance guide?

This guide provides information on the chemical resistance of flexible metallic conduit components, specifically PVC, PU, and Type LTXE thermoplastic rubber jackets. It helps determine compatibility with various chemicals.

How is chemical resistance rated for PVC and PU?

Chemical resistance for PVC and PU is rated using a scale: A (Excellent to Good), B (Good to Fair), C (Fair to Limited), and D (Unsatisfactory).

Is the chemical resistance data guaranteed for all applications?

No, the information is a guideline only, and no guarantee is implied. Results are based on controlled laboratory tests, not installed end-product applications.

What is recommended for extreme chemical exposure situations?

ABB recommends exposing and observing samples in actual service conditions for extreme or unusual situations to verify chemical resistance.

How does the LTXE thermoplastic rubber jacket resist ASTM #2 Oil?

After 7 days at 60 °C, the LTXE jacket retains 90% tensile strength and 98% elongation. At 100 °C for 4 days, it retains 66% tensile strength and 70% elongation.

What is the LTXE jacket's resistance to gasoline?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 40% tensile strength and 35% elongation, with a 17% volume increase.

How does the LTXE jacket perform with transmission oil?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 50% tensile strength and 50% elongation, with a 32% volume increase.

What is the LTXE jacket's resistance to Ethylene Glycol?

After 72 hours at 100 °C, the LTXE thermoplastic rubber jacket retains 95% tensile strength and 90% elongation, with a 2% volume increase.

How resistant is PVC to Acetic Acid 10%?

PVC has a "B" rating (Good to Fair) for resistance to Acetic Acid 10%.

What is the resistance of PU to Acetone?

PU has a "D" rating (Unsatisfactory) for resistance to Acetone.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.