Contact for Pricing
Minimum Qty: 500
Multiplier: 500
*Contact for lower quantities*
Overview
- Bronze core for flexibility and strength
- Tin copper braid for mechanical protection and EMC performance
- PVC jacket for liquid-tight sealing and environmental resistance
- Working temperature range: -55 to 105 degrees Celsius
- Compliant to RoHS and WEEE directives
Specifications
Color | Black |
Declaration of Conformity - CE | 9AKK107492A9899 |
Finish | PVC Jacket |
Inside Diameter | 2.02 in |
Inside Diameter | 51.308 mm |
Length | 600 in |
Length | 15000 mm |
Material | Bronze Core with Tin Copper Braid and PVC Jacket |
Material Quality | Bronze Core with Tin Copper Braid |
Outside Diameter | 2.375 in |
Outside Diameter | 60.325 mm |
Series | LTCES07B |
Size | 2 Inch |
Standard | RoHS, WEEE |
Trade Size | 2 in , 63 mm |
Type | Liquid Tight Flexible Metallic Conduit |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.9800 L |
Package Weight (Metric) | 0.8980 kg |

LTCES07B-C
Liquid Tight Flexible Metallic Conduit, Bronze Core with Tin Copper Braid and PVC Jacket, Conduit Size 2 Inch, Length 30 Meters/100 Feet, EMC High Performance, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
LTMES04B-C
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 1 Inch, Length 30 Meters/100 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
LTMES03B-C
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 3/4 Inch, Length 30 Meters/100 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
LTMES05B-B
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 1-1/4 Inch, Length 15 Meters/50 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
LTMES06B-B
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 15 Meters/50 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
LTMES07B-B
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 2 Inch, Length 15 Meters/50 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, Black
LTMES03B-K
Liquid Tight Flexible Metallic Conduit, Bronze Core with PVC Jacket, Conduit Size 3/4 Inch, Length 150 Meters/500 Feet, EMC Mid Performance, Halogen Free, Compliant to RoHS and WEEE, Working Temperature -55 to 105 Degrees C, BlackFrequently Asked Questions
What does "A" mean in the resistance guide?
In the chemical resistance guide, "A" signifies excellent to good resistance for the material.
How does LTXE jacket react to transmission oil?
After 72 hrs./100 °C, the LTXE jacket shows 50% tensile strength, 50% elongation, and a 32% volume increase.
What is LTXE jacket's ethylene glycol resistance?
After 72 hrs./100 °C, the LTXE jacket shows 95% tensile strength, 90% elongation, and a 2% volume increase.
What is LTXE jacket's methanol resistance?
After 72 hrs./100 °C, the LTXE jacket shows 95% tensile strength, 90% elongation, and 0% volume increase.
How does LTXE jacket perform in salt water?
After 72 hrs./100 °C, the LTXE jacket shows 80% tensile strength, 100% elongation, and a 1% volume increase.
What is LTXE jacket's Freon2 resistance?
After 72 hrs./80 °C, the LTXE jacket shows 93% tensile strength and 84% elongation.
What is LTXE jacket's gasoline resistance?
After 72 hrs./100 °C, the LTXE jacket shows 40% tensile strength, 35% elongation, and a 17% volume increase.
How does LTXE jacket resist ASTM #2 Oil?
After 7 days/60 °C, LTXE jacket retains 90% tensile strength and 98% elongation. After 18 hrs./120 °C, it retains 45% tensile strength and 40% elongation.
Which materials are covered by the guide?
The chemical resistance guide covers PVC (Polyvinyl Chloride) and PU (Polyurethane) materials.
What does "D" mean in the resistance guide?
In the chemical resistance guide, "D" indicates unsatisfactory resistance for the material.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.