ABB Installation Products LT6GES01C-C Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket…
UPC: 786210221830
Documents & Media
Contact for Pricing
Minimum Qty: 3000
Multiplier: 3000
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 316 stainless steel core with smooth extruded PVC jacket for durability and corrosion resistance
- Clear jacket enables visual inspection of conduit integrity and cable routing
- Compatible with ABB Series 5200/5300 fittings for ingress protection and system integrity
Specifications
Color | Clear |
Inside Diameter | 0.484 in |
Inside Diameter | 12.2936 mm |
Length | 100 in |
Length | 2540 mm |
Material | 316 Stainless Steel Core with PVC Jacket |
Material Quality | 316 Stainless Steel Core with PVC Jacket |
Outside Diameter | 0.71 in |
Outside Diameter | 18.034 mm |
Size | 3/8 Inch |
Standard | RoHS, IEC/EN 61386-1, -23 |
Trade Size | 3/8 in |
Type | Flexible Metallic Conduit |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.2100 L |
Package Weight (Metric) | 0.0950 kg |

LT6GES06C-B
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1-1/2 Inch, Length 15 Meters/50 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES04C-J
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 1 Inch, Length 120 Meters/400 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES08C-A
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 8 Meters/25 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES09C-A
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 3 Inch, Length 8 Meters/25 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LT6GES11C-A
Liquid Tight Flexible Metallic Conduit, 316 Stainless Steel Core with PVC Jacket, Conduit Size 4 Inch, Length 8 Meters/25 Feet, Working Temperature -20 to 80 Degrees C, Compliant to RoHS and WEEE, Clear
LTGCS09B-B
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 3 Inch, Length 15 Meters/50 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGCS08B-B
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 2-1/2 Inch, Length 15 Meters/50 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, Black
LTGCS11B-B
Liquid Tight Flexible Metallic Conduit, General Purpose, Galvanized Steel Core with PVC Jacket, Conduit Size 4 Inch, Length 15 Meters/50 Feet, Working Temperature -40 to 75 Degrees C, CSA heavy duty LR-72635, Compliant to RoHS, BlackFrequently Asked Questions
How are chemical resistance ratings defined?
Chemical resistance is rated A (Excellent to Good), B (Good to Fair), C (Fair to Limited), and D (Unsatisfactory) for PVC and PU materials.
How does LTXE jacket perform in ASTM #2 Oil?
After 7 days at 60 °C, the LTXE jacket retained 90% tensile strength and 98% elongation in ASTM #2 Oil.
What is PVC's resistance to 70% Nitric Acid?
PVC has a "D" (Unsatisfactory) resistance rating to 70% Nitric Acid.
How does LTXE jacket perform in 5% Salt Water?
After 72 hours at 100 °C, the LTXE jacket retained 80% tensile strength and 100% elongation in 5% Salt Water, with a 1% volume increase.
How does LTXE jacket perform in Transmission Oil?
After 72 hours at 100 °C, the LTXE jacket retained 50% tensile strength and 50% elongation in Transmission Oil, with a 32% volume increase.
How does LTXE jacket perform in Gasoline?
After 72 hours at 100 °C, the LTXE jacket retained 40% tensile strength and 35% elongation in Gasoline, with a 17% volume increase.
How does LTXE jacket perform in Brake Fluid?
After 72 hours at 100 °C, the LTXE jacket retained 80% tensile strength and 90% elongation in Brake Fluid, with a -7% volume increase.
What is PU's resistance to Acetone?
PU has a "D" (Unsatisfactory) resistance rating to Acetone.
What is PVC's resistance to Acetone?
PVC has a "D" (Unsatisfactory) resistance rating to Acetone.
What is PU's resistance to 10% Acetic Acid?
PU has a "B" (Good to Fair) resistance rating to 10% Acetic Acid.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.