Authorized ABB Distributor (Installation Products)
ABB - Installation Products K675LR-K2260-S - 900 Amp, 15/25kV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size Compressed Stranded 3/0 AWG or Compacted Solid 4/0 AWG. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K675LR-K2260-S 900 Amp, 15/25kV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable…

UPC: 075114258630


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K675LR-K2260-S is a high-amperage, medium-voltage elbow connector designed for reliable power distribution. Rated for 900 Amps and operating at 15/25kV, this component is crucial for connecting underground power cables to equipment. It features an insulated plug and cap for enhanced safety and environmental sealing. The integrated stud and copper compression lug ensure a secure and efficient electrical connection. This elbow connector is engineered to accommodate a wide range of cable insulation diameters, specifically from 1.090 inches to 1.310 inches. For conductor connections, it supports compressed stranded conductors sized at 3/0 AWG or compacted solid conductors at 4/0 AWG. The inclusion of a cold-shrinkable jacket seal provides an additional layer of protection against moisture and contaminants, ensuring long-term performance and system integrity. Key specifications include: * **Amperage Rating:** 900 Amps * **Voltage Rating:** 15/25kV * **Cable Insulation Diameter Range:** 1.090" - 1.310" * **Conductor Size (Compressed Stranded):** 3/0 AWG * **Conductor Size (Compacted Solid):** 4/0 AWG * **Lug Type:** Copper Compression * **Included Components:** Insulated Plug, Cap, Stud, Cable Adapter, Cold-Shrinkable Jacket Seal
  • 900 Amp, 15/25kV operating voltage
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Supports 3/0 AWG stranded or 4/0 AWG solid conductors
  • Includes insulated plug, cap, stud, lug, and cable adapter
  • Cold-shrinkable jacket seal for enhanced protection

Specifications

Amperage Rating
900 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection
Compression
Connection Type
Compression Lug
Current Rating
900 A
Environmental Conditions
All Weather Conditions, Fully Submersible
Insulation
True
Material
Copper
Material
Housing - EPDM-Rubber
Series
K675LR
Size
1.090 inch to 1.310 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.

K656LR-H2260

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.

K656ETP-L0330-DRG

600 Amp, 25kV, Deadbreak Elbow, Window Op Connector Kit with Test Point. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. With Insulated Cap.
15/25kv, 900 Amp, Two Way L Kit, Splice, Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 750. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K675L2-L2330-SG3

15/25kv, 900 Amp, Two Way L Kit, Splice, Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 750. SG3 - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
25kV, 600 Amp, Test and Ground Connector Kit with Test Point (Window Op). Cable Insulation 1.370-1.630 inches, Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed, Includes Insulated Cap, Test and Ground Reducing Tap Plug, Elbow Housing, Cable Adapter and Compression Lug. Cold Shrinkable Jacket Seal

K656ETP-M0330-DRG-S

25kV, 600 Amp, Test and Ground Connector Kit with Test Point (Window Op). Cable Insulation 1.370-1.630 inches, Aluminum Compression Lug, Conductor Size 500 Stranded/Compressed, Includes Insulated Cap, Test and Ground Reducing Tap Plug, Elbow Housing, Cable Adapter and Compression Lug. Cold Shrinkable Jacket Seal
15/25kV, 600 Amp, 1-Way L-Kit with Test Point, Cable Insulation .760-.950 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid

K656L1-G0240

15/25kV, 600 Amp, 1-Way L-Kit with Test Point, Cable Insulation .760-.950 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid
15/25kV, 600 Amp, Separable Wye Joint (3-Way) with Test Point, Spiking Aid, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 450 Stranded/Compressed, Cold Shrinkable Seal with Copper Rod and Crimp Connector

K656CYSL-L0320-SG1

15/25kV, 600 Amp, Separable Wye Joint (3-Way) with Test Point, Spiking Aid, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 450 Stranded/Compressed, Cold Shrinkable Seal with Copper Rod and Crimp Connector

Frequently Asked Questions

What is the maximum conductor size supported by this elbow connector?

This ABB elbow connector supports compressed stranded conductors up to 3/0 AWG and compacted solid conductors up to 4/0 AWG.

What is the voltage rating for the K675LR-K2260-S elbow connector?

The K675LR-K2260-S elbow connector is rated for 15/25kV operation.

What is the range of cable insulation diameters this connector can handle?

This connector is designed for cable insulation diameters ranging from 1.090 inches to 1.310 inches.

What components are included with the ABB K675LR-K2260-S?

The K675LR-K2260-S includes an insulated plug, cap, stud, cable adapter, and a cold-shrinkable jacket seal.

What type of lug is used for conductor connection?

A copper compression lug is utilized for secure conductor connection with this elbow connector.

How to Install 655/675LR and K655/K675LR Deadbreak Elbow Connectors

A comprehensive guide for the safe and correct installation of 600-ampere or 900-ampere deadbreak elbow connectors on 15kV and 25kV class systems, ensuring fully shielded and submersible cable connections.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Measuring tape or ruler, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable sensing device (for capacitive test points), Torque wrench

Supplies needed:

655/675LR or K655/K675LR Deadbreak Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), No. 14 AWG Copper wire (minimum, for grounding), Suitable grounding connector, HV insulated cap(s) or connector(s) (if replacing shipping covers), Waterproofing material (for cable jacket), Silicone lubricant (for voltage test cap)

  1. Ensure Safety and Inspect Components

    DANGER: De-energize all apparatus before beginning installation. Inspect all kit contents for completeness and damage. Verify compatibility and proper fit with the cable and mating products. Gather all required tools and maintain a clean work area.

  2. Position and Cut Cable

    Assemble the cable in its final position, allowing enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Prepare Cable Outer Jacket, Insulation, and Shield

    Clean the outer surface of the cable for 24 inches (610mm). Remove the outer jacket (if applicable) and prepare the cable insulation, semi-con shield, and tape marker according to the specific cable type diagrams provided in the documentation, ensuring precise dimensions.

  4. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Trim Insulation and Verify Conductor Length

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If not, re-do the assembly.

  6. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it. Measure the 'Check Dimension' before crimping (must be less than 6-3/8 inches). Crimp the lug according to its supplied instructions. Wipe off all excess inhibitor. After crimping, the distance from the lug end to the cable adapter must be between 6-3/8 inches and 7-1/8 inches (162mm-181mm).

  7. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  8. Prepare Mating Parts

    WARNING: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud (if supplied with the elbow) into the mating part if it's not already equipped. Clean and lubricate both the elbow and the mating part with the supplied lubricant, keeping surfaces clean.

  9. Connect Elbow to Mating Apparatus

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  10. Connect Opposite Mating Part

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions.

  11. Install Insulating Plug (Optional)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place.

  12. Ground the Cable Shield and Waterproof

    Insert one end of a wire (minimum No. 14 AWG Copper) through the grounding eye and twist to form a small loop; do not damage the eye. Connect this wire to ground using a suitable connector. Ensure the cable shield is grounded, either via a grounding device or an alternate method. Waterproof the cable jacket to prevent moisture ingress.

  13. Perform Voltage Test

    WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Remove the test point cap with a hotstick, peeling off at an angle. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until 'no voltage' is confirmed by other means. After testing, clean and lubricate the cap, then replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.