Authorized ABB Distributor (Installation Products)
ABB - Installation Products K671BGAD - 15/25kV, 600 Amp Series Grounding Device with 1 inch diameter Ball - Hot Line Clamp Grounding Bus. Conforms to IEEE Standard 386. Mates with K676BGADDR insulated Receptacle. Use 1 inch Hex for Assembly.

ABB Installation Products K671BGAD 15/25kV, 600 Amp Series Grounding Device with 1 inch diameter Ball - Hot Line Clamp…

UPC: 075114144513


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K671BGAD is a 15/25kV, 600 Amp Series Grounding Device designed for medium-voltage electrical systems requiring reliable grounding. This hot-line clamp grounding bus features a 1-inch diameter ball for secure, consistent contact in high-current applications. The K671BGAD is specifically designed to mate with the K676BGADDR insulated receptacle, providing a complete grounding solution for medium-voltage systems. Assembly is straightforward, requiring only a 1-inch hex tool for installation. This grounding device is critical for safe maintenance procedures, offering a secure point for system grounding and proper fault current dissipation in medium-voltage applications. Its robust construction and adherence to IEEE standards make it suitable for environments where dependable grounding is essential. The 600 Amp current rating supports high-fault conditions, while the 15/25kV voltage rating covers a broad range of medium-voltage applications. The hot-line clamp design allows for installation and removal under load, reducing downtime during maintenance. This product is part of ABB's Installation Products line, ensuring compatibility with industry-standard components.
  • Voltage Rating: 15/25 kV for medium-voltage applications
  • Current Rating: 600 Amp for high-fault conditions
  • 1-inch diameter ball for secure, consistent contact
  • Hot-line clamp design allows installation/removal under load
  • Conforms to IEEE Standard 386 for safety and performance
  • Mates with K676BGADDR insulated receptacle for complete grounding solution
  • Assembly requires 1-inch hex tool for easy installation

Specifications

Amperage Rating
600 A
Application
15/25 kV, 600 Amps
Conductor Material
Copper , EPDM Rubber
Connection
Push-In
Connection Type
Hot Line Clamp Grounding Bus
Current Rating
600 A
Insulation
EPDM Rubber
Length
10.65 in
Series
K671
Size
1 inch diameter Ball
Special Features
1 inch (25.4mm) Diameter Ball
Standard
ANSI/IEEE Standard 386
Type
Grounding Device Ball Type
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Wall Plate Standard 1 Gang Blank WH

600WH-25

Wall Plate Standard 1 Gang Blank WH
600T Modified for Switchboard Users

600T-MOD

600T Modified for Switchboard Users
One-Gang Nail-On New Work Outlet Box, Volume 18 Cubic Inches, Length 3-3/4 Inches, Width 2-1/4 Inches, Depth 2-7/8 Inches, Color Blue, Material PVC, Mounting Means Captive Nails

B118A

One-Gang Nail-On New Work Outlet Box, Volume 18 Cubic Inches, Length 3-3/4 Inches, Width 2-1/4 Inches, Depth 2-7/8 Inches, Color Blue, Material PVC, Mounting Means Captive Nails
Two-Gang Nail-On New Work Outlet Box, Volume 32 Cubic Inches, Length 3-3/4 Inches, Width 4 Inches, Depth 3 Inches, Color Blue, Material PVC, Mounting Means Captive Nails

B232ACP

Two-Gang Nail-On New Work Outlet Box, Volume 32 Cubic Inches, Length 3-3/4 Inches, Width 4 Inches, Depth 3 Inches, Color Blue, Material PVC, Mounting Means Captive Nails
One-Gang Box Cover, Volume 8.1 Cubic Inches, 4 Inches Square, Raised 1-1/4 Inch, Color Blue, Material Non-Metallic

A414

One-Gang Box Cover, Volume 8.1 Cubic Inches, 4 Inches Square, Raised 1-1/4 Inch, Color Blue, Material Non-Metallic
One-Gang Low-Voltage Old Work Bracket, Length 4.32 Inches, Width 2.52 Inches, Depth 1.66 Inches, Color Orange, Material Non-Metallic

SC100RR

One-Gang Low-Voltage Old Work Bracket, Length 4.32 Inches, Width 2.52 Inches, Depth 1.66 Inches, Color Orange, Material Non-Metallic
One-Gang Low-Voltage Adjustable Bracket, Color Orange, Material Non-Metallic

SC100ADJC

One-Gang Low-Voltage Adjustable Bracket, Color Orange, Material Non-Metallic
Heat Shrink Ring Terminal 12 10 AWG, 3/8" stud size.

PH10-38R-E

Heat Shrink Ring Terminal 12 10 AWG, 3/8" stud size.
One-Gang Box Cover, Volume 3.5 Cubic Inches, 4 Inches Square, Raised 1/2 Inch, Color Blue, Material Non-Metallic

A410R-CAR

One-Gang Box Cover, Volume 3.5 Cubic Inches, 4 Inches Square, Raised 1/2 Inch, Color Blue, Material Non-Metallic
The Polaris IPLMD350-6 Multi-Tap Mountable Dual-Sided Entry Connector features 6 ports sized for 350 MCM - 6 AWG wires. Mounting holes on either side of the connector allow for direct mounting to troughs, panels or wireways with 1/4†bolts. The body is made from aluminum alloy wrapped in a layer of plastisol insulation. Each dual-sided port is pre-loaded with an oxide inhibitor, with removable access plugs over the hex screws used to tighten the connections. Installs with a hex key and torque wrench, without any tape or additional supplies. Designed for use in a wide range of splicing applications, including installation in cable trays, panel boards, ducts, raceways or troughs.

IPLMD350-6

The Polaris IPLMD350-6 Multi-Tap Mountable Dual-Sided Entry Connector features 6 ports sized for 350 MCM - 6 AWG wires. Mounting holes on either side of the connector allow for direct mounting to troughs, panels or wireways with 1/4†bolts. The body is made from aluminum alloy wrapped in a layer of plastisol insulation. Each dual-sided port is pre-loaded with an oxide inhibitor, with removable access plugs over the hex screws used to tighten the connections. Installs with a hex key and torque wrench, without any tape or additional supplies. Designed for use in a wide range of splicing applications, including installation in cable trays, panel boards, ducts, raceways or troughs.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A

Frequently Asked Questions

What is the benefit of the GAD's direct test point?

It provides a direct test point and grounding connection for maximum personnel safety, allowing checks for de-energization.

Does the GAD eliminate temporary grounding adapters?

Yes, the GAD eliminates the need to install temporary grounding adapters, providing a direct and permanent grounding connection.

What current applications is the GAD suitable for?

The GAD is suitable for 600 A and 900 A applications. It features full copper construction.

How is the Elastimold GAD installed?

The Elastimold GAD easily installs in the rear interface of a 600 A series elbow connector (T-body).

What grounding clamp types are compatible with the GAD?

The GAD is available for both C-clamp and ball-stud grounding clamp types. Series BGAD and BGADDR are for ball-stud connections.

What system classes are available for the GAD?

The Elastimold GAD is available for 15 kV, 25 kV, and 35 kV system classes.

Is the Elastimold GAD hot-stick workable?

Yes, the Elastimold grounding-aid device is designed to be hot-stick workable.

How does the GAD help check system de-energization?

It includes a removable protective cap with a capacitive test point, allowing easy access to check if the system is de-energized.

What is the short circuit withstand rating?

The Elastimold GAD has a short circuit withstand rating of up to 25 kA. It is designed for 600 A and 900 A applications.

What is the purpose of the Elastimold GAD?

The Elastimold GAD provides a permanent, reliable, direct 600 A or 900 A, 25 kA rated ground connection. It is used when available fault currents exceed 10 kA in underground systems.

How to Install the K671BGAD Grounding Device and K676BGADDR Insulated Cap

A comprehensive guide for the safe installation and initial setup of the K671BGAD Deadbreak Grounding Device and K676BGADDR Insulated Cap with Test Point on a 600Amp elbow.

Estimated time: 1h

Tools needed:

1” deep socket (P/N 600-570), Torque wrench, Hotstick tools (x2), Capacitive voltage sensing device

Supplies needed:

Supplied lubricant (DO NOT SUBSTITUTE), Copper wire (No 14 AWG / 2.55mm), Silicone lubricant, Socket type hot line grounding clamp and cable

  1. Prepare for Installation and Safety Checks

    Ensure all apparatus are de-energized before beginning installation or removal of any parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect all parts for damage, correct rating, and compatibility with mating components. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit. Read all instructions thoroughly before starting.

  2. Install the K671BGAD Grounding Connector

    First, install the 600Amp elbow onto the apparatus bushing following the instructions provided with the elbow; do not install any insulating plug or cap. Clean and lubricate both the K671BGAD Grounding Connector interface and the 600Amp elbow interface using only the supplied lubricant. Insert the K671BGAD Grounding Connector into the elbow and rotate it clockwise to engage the stud. Engage a 1” deep socket (P/N 600-570) onto the K671BGAD Grounding Connector and use a torque wrench to continue rotating clockwise. Once the connector stops rotating, tighten it to 55/60 foot/pounds torque. Remove the socket. Insert one end of a separate copper wire (No 14AWG/2.55mm) through the grounding eye on the K671BGAD Grounding Connector, twist it tightly without damaging the eye, and connect the free end to the system ground.

  3. Install the K676BGADDR Insulating Cap

    Insert one end of a separate copper wire (No 14 AWG / 2.55mm) through the grounding eye of the insulated cap, form a small loop, and twist tightly. Connect the free end of this grounding wire to the system ground, ensuring its length is sufficient to reach the grounding point plus an additional 90 inches for wrapping. Clean and lubricate the K676BGADDR insulating cap and the K671BGAD interface with the supplied lubricant. Attach a first hotstick tool to the insulated cap's assembly/disassembly bail and push the receptacle onto the bushing interface until it stops. With a second hotstick, engage the grounding wire and apply slight tension, wrapping it loosely around the center of the insulated cap. While pushing against the bushing interface with the first hotstick, rotate clockwise until the threads between the bushing and the cap engage. Discontinue pushing and continue turning until resistance is felt; DO NOT OVERTIGHTEN. Remove the second hotstick.

  4. Install the Ground Clamp (Optional)

    If temporary grounding is required, attach a socket type hot line grounding clamp and cable to the 1” diameter copper ball extending from the K671BGAD interface. Always follow your utility’s specific operating procedures for this step.

  5. Perform Voltage Test (Before Disconnecting)

    WARNING: DO NOT DISCONNECT WHILE ENERGIZED. To ensure the system is de-energized, perform a voltage test. Remove the voltage detection point cap from the K676BGADDR insulated cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points, following the manufacturer’s directions. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious injury. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it securely on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.