Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656LR-K0270 - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 4/0 or Compact/Solid 250 or mm2 Compact 125.

ABB Installation Products K656LR-K0270 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 783786253104


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-K0270 is a 15/25kV, 600 Amp series deadbreak elbow connector engineered for reliable medium-voltage underground power distribution systems. This fully shielded, dead-front connector provides a secure, submersible cable connection to high-voltage apparatus, ensuring safe and efficient power delivery in demanding environments. Designed for compatibility with compressed/stranded conductors of 4/0 AWG, compact/solid conductors of 250 kcmil, or mm2 compact conductors of 125 mm², the K656LR-K0270 accommodates cable insulation diameters ranging from 1.090 inches to 1.310 inches. The included test point enables safe, non-intrusive energized circuit testing, simplifying maintenance and troubleshooting while enhancing operational safety. Constructed with a durable aluminum compression lug, this deadbreak elbow delivers a robust electrical connection resistant to corrosion and mechanical stress. The molded rubber housing, fully shielded and submersible, meets ANSI/IEEE Standard 386 for medium-voltage applications. With a continuous current rating of 600 Amps and impulse withstand capability of 95kV BIL (for 15kV class), the K656LR-K0270 is ideal for underground distribution systems, pad-mounted transformers, and switchgear installations. Key applications include: - Medium-voltage underground cable connections - Pad-mounted transformer terminations - Switchgear and control panel interfaces - Submersible and wet environments The K656LR-K0270 is part of ABB’s Installation Products line, offering a complete connection solution with an insulated plug, cap, stud, lug, and cable adapter. Its non-corrosive, capacitive test point ensures long-term reliability, while the compression lug design guarantees a secure, low-resistance connection for high-performance power distribution.
  • Voltage rating: 15/25kV with 600 Amp continuous current
  • Test point included for safe energized circuit testing
  • Aluminum compression lug for secure, corrosion-resistant connections
  • Compatible with 4/0 AWG, 250 kcmil, or 125 mm² compact conductors
  • Cable insulation diameter range: 1.090" to 1.310"
  • Fully shielded, submersible molded rubber housing
  • Meets ANSI/IEEE Standard 386 for medium-voltage applications

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.4000 L
Package Weight (Metric)
2.9030 kg
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. No Sealing Kit.

K656CETP-J0270

25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. No Sealing Kit.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #2 or Compact/Solid #1 or mm2 Compact 35. 0MA - Metallic Tape Shield Adapter.

K656LR-J0220-0MA

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded #2 or Compact/Solid #1 or mm2 Compact 35. 0MA - Metallic Tape Shield Adapter.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. 0MA - Metallic Tape Shield Adapter.

K656LR-K0240-0MA

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 1/0 or Compact/Solid 2/0. 0MA - Metallic Tape Shield Adapter.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300.

K656LR-J0280

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.280 inch to 1.430 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900. Cold-Shrinkable Jacket Seal Included.

K656LR-LM0380-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.280 inch to 1.430 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.280 inch to 1.430 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold-Shrinkable Jacket Seal Included.

K656LR-LM0330-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.280 inch to 1.430 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-K0300-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K656LR-L0330

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes are compatible with the K656LR elbow connector?

The K656LR is designed for conductor ranges from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this deadbreak elbow?

The K656LR elbow connector has a continuous current rating of 600 Amps.

What insulation diameters can the K656LR accommodate?

The connector can accommodate insulation diameters ranging from 0.640 inches to 1.935 inches.

Does the K656LR meet any industry standards?

Yes, the K656LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand rating for the 28kV voltage class?

For the 28kV voltage class, the impulse withstand rating is 140kV BIL for a 1.2 x 50 microsecond wave.

What is the corona extinction rating for the 15kV voltage class?

The corona extinction rating for the 15kV voltage class is 11kV AC at 3pC sensitivity.

What materials are used in the construction of the K656LR?

The K656LR features a 100% peroxide-cured construction using insulation and conductive EPDM materials.

Can the K656LR be easily connected or disconnected?

Yes, it can be easily connected or disconnected using standard hand tools and equipment when the system is de-energized.

Are there any recommended accessories for safety?

Yes, an ECS cable seal grounding device is highly recommended for safety when used on metallic tape shield or drain wire cable.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and connection of K655/K675LR and 655/675LR deadbreak elbow connectors. It covers cable preparation, lug crimping, and final assembly for high voltage systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable voltage sensing device, Cleaning supplies

Supplies needed:

K655/K675LR or 655/675LR Deadbreak Elbow Connector kit, Lubricant (silicone), Threaded stud, No. 14 AWG Copper wire (or equivalent), Suitable grounding connector, Tape marker, Grounding device (if applicable), HV insulated cap(s) or connector(s) (for shipping cover replacement)

  1. Prepare Cable for Assembly

    DANGER: All apparatus must be de-energized during installation. Position the cable with enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the center line of the mating product. Clean the outer surface of the cable for 24” (610mm) or up to the bent back concentric neutral wires. Remove the outer jacket (if applicable) and prepare the cable according to its type (e.g., Non-Jacketed, Jacketed Shield Wires, Flat Metallic Tape Shield, Fabric Tape Shield, Longitudinally Corrugated Shield). Refer to specific instructions for any grounding devices or cable seals being used.

  2. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  3. Prepare Conductor and Crimp Lug

    Remove protruding cable insulation by cutting it even with the end of the cable adapter, taking care not to nick the adapter or conductor. Ensure the exposed conductor length is 4-1/4” – 4-9/16” (108mm-116mm); if not, redo. For copper, fully insert the conductor into the compression lug. For aluminum, wire brush the conductor and immediately insert it. Before crimping, verify the 'Check Dimension' is less than 6-3/8”. Crimp the lug per its instructions, starting at the cable end. Wipe off excess inhibitor. After crimping, confirm the distance from the lug end to the cable adapter is 6-3/8” to 7-1/8” (162mm-181mm); if not, redo.

  4. Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  5. Connect Mating Products

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZED WHILE DISCONNECTED. Remove protective caps from the elbow and mating part. If the mating part lacks a stud, hand tighten the supplied threaded stud into it. Clean and lubricate both the elbow and mating part, keeping surfaces clean. Push the elbow onto the mating part, aligning the compression lug hole with the stud. Clean and lubricate the mating part for the elbow's opposite end. Insert and hand tighten the mating part, then torque it per its instructions. If using an insulating plug, clean and lubricate its voltage detection cap and push it onto the elbow until it snaps into place.

  6. Ground the Cable Shield

    Insert one end of a wire (at least No. 14 AWG Copper equivalent) through the grounding eye, twist to form a small loop, and connect it to ground using a suitable connector. Ensure the cable shield is grounded according to the grounding device instructions or an alternate method if no device is used. Waterproof the cable jacket to prevent moisture ingress.

  7. Perform Voltage Test and Finalize

    CAUTION: For 600amp L-Kits, tighten each component to specified torque. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, following its manufacturer’s directions, to determine if the cable is energized. Contamination, moisture, or incorrect equipment can cause false readings. Treat the elbow as energized until 'no voltage' is confirmed by other means to prevent serious injury. After testing, clean and lubricate the cap's inner surface with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.