ABB - Installation Products K656LR-G5230-S-TL - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50. Cold-Shrinkable Jacket Seal Included. With Sheild Adapter.

ABB Installation Products K656LR-G5230-S-TL 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 783786796472


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-G5230-S-TL is a 15/25 kV, 600 A deadbreak elbow connector designed for reliable medium-voltage cable terminations in industrial and utility applications. This series features a bi-metal compression lug compatible with compressed or stranded #1 or compact/solid 1/0 AWG conductors, as well as mm² compact 50 conductors, ensuring versatility across common cable sizes. The connector accommodates cable insulation diameters from 0.760 inch to 0.950 inch, providing a secure fit for standard medium-voltage cables. Key components include an insulated plug, cap, stud, lug, and cable adapter, all engineered for deadbreak operation—allowing connections and disconnections under load without interrupting service. The cold-shrinkable jacket seal delivers a watertight, corrosion-resistant barrier, while the included shield adapter maintains electrical continuity and grounding integrity. The deadbreak design eliminates the need for de-energizing circuits during maintenance or upgrades, reducing downtime and improving operational efficiency. This elbow connector is ideal for underground distribution systems, switchgear, transformers, and pad-mounted equipment where safe, reliable, and maintenance-friendly terminations are critical. Compliance with industry standards ensures long-term performance in harsh environments, including exposure to moisture, contaminants, and mechanical stress. The ABB K656LR-G5230-S-TL is a proven solution for utilities, industrial facilities, and commercial installations requiring dependable medium-voltage cable connections.
  • 15/25 kV voltage rating with 600 A current capacity
  • Bi-metal compression lug for #1 or 1/0 AWG conductors (compressed/stranded) or mm² compact 50
  • Cable insulation diameter range: 0.760 inch to 0.950 inch
  • Deadbreak operation with insulated plug, cap, stud, lug, and cable adapter
  • Cold-shrinkable jacket seal and shield adapter included

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point. Cold-Shrinkable Jacket Seal Included. Shield Adapter
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.

K656YSR-H0230

600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size kcmil Compressed/Stranded 1000.

K655LR-P0410

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size kcmil Compressed/Stranded 1000.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K656LR-H0290

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 900 or Compact/Solid 1000 or mm2 Compact 500.

K656LR-N0400

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 900 or Compact/Solid 1000 or mm2 Compact 500.
00 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation 1.280 to 1.430 inch. Aluminum Lug, Conductor Size 750 stranded/compressed. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-LM0360-SG3

00 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation 1.280 to 1.430 inch. Aluminum Lug, Conductor Size 750 stranded/compressed. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 250 stranded/compressed.

K656LR-H0280

15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 250 stranded/compressed.
600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 250 stranded/compressed. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-H0280-SG3

600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 250 stranded/compressed. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation 1.180 to 1.465 inch. Aluminum Lug, Conductor Size 500 stranded/compressed. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-L0330-SG3

600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation 1.180 to 1.465 inch. Aluminum Lug, Conductor Size 500 stranded/compressed. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR-W0X?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR-W0X accommodate?

It can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the continuous current rating for this elbow connector?

The K656LR-W0X has a continuous current rating of 600 Amps.

Is a grounding device recommended for use with this product?

Yes, when used on metallic tape shield or drain wire cable, an ECS cable seal grounding device for safety is highly recommended.

Can this elbow connector be used in submersible applications?

Yes, the K656LR is designed for fully shielded, dead-front submersible cable connections.

What is the impulse withstand rating for the 28kV voltage class?

The impulse withstand rating for the 28kV voltage class is 140kV BIL for a 1.2 x 50 microsecond wave.

What is the corona extinction rating for the 15kV voltage class?

The corona extinction rating for the 15kV voltage class is 11kV AC at 3pC sensitivity.

What cable insulation diameters are supported by the K656LR-W0X?

The product supports cable insulation diameters ranging from 0.640 inches to 1.935 inches.

What is the AC one-minute withstand voltage for the 15kV class?

The AC one-minute withstand voltage for the 15kV voltage class is 34kV.

What is the momentary current rating for the K656LR-W0X?

The momentary current rating is 25kA Sym for 10 Cycles.

How to Install K656LR-G5230-S-TL Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K656LR-G5230-S-TL deadbreak elbow connectors. It covers cable preparation, connector assembly, and initial voltage testing for 15kV and 25kV class systems.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush, Torque wrench, Hotstick, Suitable sensing device

Supplies needed:

Elbow connector, Cable adapter, Compression lug, Insulating plug, Lubricant, Threaded stud, Tape marker, Wire (No. 14 AWG Copper equivalent or greater), Suitable grounding connector, Protective caps, HV insulated cap(s) or connector(s), Silicone lubricant

  1. Perform Initial Safety Checks and Part Inspection

    Ensure all apparatus are de-energized before starting installation. Inspect all parts for damage, verify ratings, and confirm compatibility with mating parts. Check the package contents for completeness and ensure all required tools are at hand. Remove any protective shipping covers and replace them with appropriate HV insulated caps or connectors before energizing the circuit.

  2. Prepare the Cable for Assembly

    Assemble the cable in its final position, leaving enough slack to allow for elbow removal. If using concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean the Cable Outer Surface

    Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.

  4. Prepare the Cable Insulation and Shield

    Remove the outer jacket (if applicable) and prepare the cable according to its type (e.g., non-jacketed concentric neutral, jacketed shield wires, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield). Refer to specific instructions for 20MA/21MA grounding devices or 10TL cable shield adapters if used.

  5. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Expose the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution to avoid cutting or nicking the cable adapter or the conductor. The exposed conductor length must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm); otherwise, redo the assembly.

  7. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the lug. Measure the 'Check Dimension' before crimping (must be less than 6-3/8 inches). Crimp the compression lug according to its supplied instructions. Wipe off any excess inhibitor. The distance from the end of the lug to the cable adapter after crimping should be 6-3/8 to 7-1/8 inches (162mm-181mm); otherwise, redo the assembly.

  8. Install the Elbow onto the Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  9. Prepare Mating Products

    WARNING: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part with the provided lubricant, ensuring surfaces remain clean.

  10. Connect the Elbow to the Mating Part

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part.

  11. Connect the Opposite Mating Part

    Clean and lubricate the mating part intended for the opposite end of the elbow. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions.

  12. Install Insulating Plug (If Applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down firmly until it snaps into place.

  13. Ground the Cable Shield

    Insert one end of a No. 14 AWG Copper equivalent wire through the grounding eye and twist it to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions for any grounding device used, or employ an alternate method if no device is present. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  14. Ensure Proper Torque for L-Kits (If Applicable)

    CAUTION: When constructing 600-amp L-Kits, ensure each component is tightened to the specified torque as per the provided instructions.

  15. Remove the Test Point Cap

    Remove the test point cap using a hotstick. When removing, peel it off at an angle rather than pulling directly in line with the test point assembly.

  16. Perform Voltage Test

    WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized, following the meter manufacturer's directions. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means, as contamination or incorrect equipment can provide false readings, leading to serious or fatal injury.

  17. Replace the Test Point Cap

    After voltage detection is complete, clean and lubricate the inside surface of the cap with silicone lubricant and replace it securely on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.