ABB - Installation Products K655RLR-J2300 - 600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

ABB Installation Products K655RLR-J2300 600 Amp, 15/25kV, 600 Series Deadbreak, Replacement Elbow without Test Point, Cable…

UPC: 783786805815


Documents & Media
Manufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655RLR-J2300 is a 600 Amp, 15/25kV deadbreak elbow designed for reliable medium-voltage cable connections in industrial and utility applications. This replacement elbow features a 600 Series deadbreak interface with no test point, ensuring compatibility with existing deadbreak bushings and elbows. The unit accommodates cable insulation diameters from 0.980 to 1.180 inches, making it suitable for 350 kcmil compressed stranded, 400 kcmil compacted solid, or 185 mm² compact copper conductors. The integrated copper compression lug provides secure, low-resistance terminations for high-current circuits. Rated for 600A continuous operation, this elbow is ideal for switchgear, transformers, and cable terminations where safe, insulated disconnection is required. The deadbreak design allows for hot-stick operation, enabling maintenance without de-energizing the system. This specific model, the K655RLR-J2300, is a replacement elbow without a test point, part of the 600 Series deadbreak product line. The copper compression lug is a key component for ensuring a robust connection. The conductor size compatibility extends to AWG or kcmil, with specific values for compressed stranded (350), compacted solid (400), and mm² compact (185) conductors. The 15/25kV rating signifies its suitability for medium-voltage applications within this range.
  • 600 Amp continuous current rating for high-power applications
  • 15/25kV voltage class for medium-voltage systems
  • Deadbreak interface with no test point for safe operation
  • Cable insulation diameter range: 0.980 to 1.180 inches
  • Copper compression lug for 350/400 kcmil or 185 mm² compact conductors

Specifications

Amperage Rating
600 A
Application
Used where Cable has been severed and is not long enough to reach the Elbow
Color
Black
Conductor Range
350 kcmil , 400 kcmil
Connection
Compression
Connection Type
Deadbreak
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Length
31.56 in
Length
801.624 mm
Material
Copper Compression Lug
Material
Housing - EPDM-Rubber
Series
600 Series
Size
0.980 inch to 1.180 inch (cable insulation diameter)
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Rubber. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Replacement Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. 200ECS-G1 Jacket Seal and Grounding Kit Included.

K655LR-K0300-SG1

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. 200ECS-G1 Jacket Seal and Grounding Kit Included.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K676LR-L2360-SG3

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K676LR-H2300-SG3

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size Compressed Stranded 400 kcmil or Compacted Solid 450 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K676LR-K2310-SG3

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size Compressed Stranded 400 kcmil or Compacted Solid 450 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K676LR-K2300-SG3

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size Compressed Stranded 350 kcmil or Compacted Solid 400 kcmil. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 350 Stranded/Compressed. With Jacket Seal

K676LR-H2300-S

15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .850-1.050 inches, Copper Compression Lug, Conductor Size 350 Stranded/Compressed. With Jacket Seal
15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact.

K676LR-J2330

15/25kV, 900 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .980-1.180 inches, Copper Compression Lug, Conductor Size 500 Stranded/Compressed or 600 Solid/Compact.
900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K676LR-K2330-SG3

900 Amp, 15/25kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

What cable insulation diameter does this elbow support?

The elbow supports cable insulation diameters between 0.980 and 1.180 inches.

What conductor sizes are compatible with this elbow?

Compatible conductor sizes are 350 kcmil compressed stranded, 400 kcmil compacted solid, or 185 mm² compact copper.

What voltage class does this elbow support?

The elbow is rated for 15/25kV medium-voltage applications.

Does this elbow include a test point?

No, this is a deadbreak elbow without a test point.

What is the continuous current rating of this elbow?

The continuous current rating is 600 Amps.

Is this elbow rated for hot-stick operation?

Yes, the deadbreak design allows for safe hot-stick operation without de-energizing the system.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.