ABB - Installation Products K655LR-L0390 - 15/25kV 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Conductor Size kcmil Compressed/Stranded 800.

ABB Installation Products K655LR-L0390 15/25kV 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable…

UPC: 783786436620


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15/25kV 600 Series Deadbreak Elbow, SKU K655LR-L0390, is a fully shielded, submersible, and separable high-voltage cable termination solution designed for underground distribution and pad-mounted transformer applications. This deadbreak elbow accommodates conductor sizes up to 800 kcmil (compressed/stranded) for both aluminum and copper cables, with insulation diameters ranging from 0.640" to 1.935". The 600 Series design ensures a fully insulated interface, enabling safe connection and disconnection in de-energized states using standard hand tools. Key specifications include a continuous current rating of 900 Amps and a momentary rating of 25kA symmetrical for 10 cycles. The elbow meets ANSI/IEEE Standard 386, with voltage ratings of 8.3kV phase-to-ground and 14.4kV phase-to-phase for 15kV class, and 16.2kV phase-to-ground and 28kV phase-to-phase for 25kV class. Impulse withstand ratings are 95kV BIL for 15kV and 140kV BIL for 25kV, with AC withstand ratings of 34kV and 45kV respectively. Corona extinction sensitivity is 11kV AC for 15kV and 21.5kV AC for 25kV at 3pC. The kit includes an insulated plug with cap, copper compression lug, copper stud, and cable adapter, providing a complete termination solution. The fully molded rubber housing is peroxide-cured EPDM, ensuring durability and resistance to environmental conditions. Optional accessories enable visible external separation, bypass, isolation, dead-ending, grounding, testing, and the addition of taps, surge arrestors, or fault current indicators. Compatible with metallic tape shield or drain wire cables, an ECS cable seal grounding device is recommended for optimal performance. This deadbreak elbow is engineered for utility and industrial power distribution networks where reliable, submersible cable terminations are critical. Its dead-front design eliminates exposed live parts, enhancing safety during installation and maintenance. The separable interface allows for quick and secure connections to high-voltage apparatus, including transformers and switchgear, without the need for specialized tools or procedures.
  • Fully shielded, submersible, and separable deadbreak design for safe, de-energized connections
  • Accommodates conductor sizes up to 800 kcmil (compressed/stranded) for aluminum and copper cables
  • Continuous current rating: 900 Amps; Momentary rating: 25kA symmetrical for 10 cycles
  • Voltage ratings: 15kV (8.3kV phase-to-ground, 14.4kV phase-to-phase) and 25kV (16.2kV phase-to-ground, 28kV phase-to-phase)
  • Includes insulated plug, cap, copper stud, lug, and cable adapter for complete termination

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
800 kcmil
Connection Type
Deadbreak Elbow
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Series
600 Series
Size
800 kcmil
Special Features
Fully shielded, fully submersible molded rubber housing. 100 Percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. Optional accessories allow visible external separation, by-pass, isolation, dead-ending, grounding, and testing as well as adding taps, surge arrestors, and fault current indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.4000 L
Package Weight (Metric)
2.9030 kg
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 800.

K655LR-M0390

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size kcmil Compressed/Stranded 800.
600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K655LR-H0290

600 Amp, 15/25kV, 600 Series Deadbreak, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. 200ECS Jacket Seal Included.

K655LR-K0300-S

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. 200ECS Jacket Seal Included.
Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 450 or Solid 500/550. 200ECS Jacket Seal Included.

K656LR-L0320-S

Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 450 or Solid 500/550. 200ECS Jacket Seal Included.
Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 3/0 or Solid 4/0 /mm2 95.

K656LR-J0260

Elbow Connector with Test Point, 600 Amp, Dead Break, 15/25 KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 3/0 or Solid 4/0 /mm2 95.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400. 200ECS-G3 Jacket Seal and Grounding Kit Included.

K655LR-M0360-SG3

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400. 200ECS-G3 Jacket Seal and Grounding Kit Included.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.

K655LR-L0290

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size kcmil Compressed/Stranded 300 or Compact/Solid 350 or mm2 Compact 150.
600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95. 200ECS Jacket Seal Included.

K655LR-K0260-S

600 Series Elbow with insulated plug, cap, stud, lug and cable adapter, 15/25KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 3/0 or Compact/Solid 4/0 or mm2 Compact 95. 200ECS Jacket Seal Included.

Frequently Asked Questions

What is the maximum operating voltage for this elbow connector?

The elbow connector can be used through 28kV. For the 15kV voltage class, the max operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes and insulation diameters are supported?

It supports conductor ranges from #2 AWG to 1250 kcmil for aluminum and copper. Insulation diameters range from 0.640 inches to 1.935 inches.

What is the continuous current rating?

The elbow connector has a continuous current rating of 600 Amps.

What is the momentary current rating?

The momentary current rating is 25kA symmetrical for 10 cycles.

What are the impulse withstand ratings?

For the 15kV class, it is 95kV BIL. For the 28kV class, it is 140kV BIL.

What is the AC withstand voltage for one minute?

For the 15kV class, the one-minute AC withstand is 34kV. For the 28kV class, it is 45kV.

What is the DC withstand voltage for 15 minutes?

For the 15kV class, the 15-minute DC withstand is 53kV. For the 28kV class, it is 84kV.

What is the corona extinction rating?

For the 15kV class, the corona extinction is 11kV AC at 3pC sensitivity. For the 28kV class, it is 21.5kV AC at 3pC sensitivity.

What standards does this product meet?

The product meets ANSI/IEEE Standard 386, Latest Revision.

What materials are used in its construction?

The housing is made of molded rubber, and the 100% peroxide-cured construction includes insulation and conductive EPDM materials.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K655/K675LR and 655/675LR Deadbreak Elbow Connectors, including cable preparation, lug crimping, and connection to mating apparatus. Always ensure all apparatus are de-energized before beginning installation to prevent serious injury.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Cutting tool, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

K655/K675LR Deadbreak Elbow Connector, Cable Adapter, Compression Lug, Insulating Plug (if used), Lubricant (silicone), Threaded Stud (Stud Prepack), Tape Marker, Wire (No. 14 AWG Copper or equivalent for grounding), Suitable connector (for grounding wire), Waterproofing material (for cable jacket), Mating part (e.g., Apparatus Bushing, Tap Plug), HV insulated cap(s) or connector(s)

  1. Assemble Cable and Cut

    Assemble the cable in its final assembled position with enough slack to provide adequate clearance for removing the elbows. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4” (45mm) from the center line of the mating product.

  2. Clean Cable Outer Surface

    Clean the outer surface of the cable a distance of 24” (610mm) or up to the bent back concentric neutral wires.

  3. Prepare Cable

    Prepare the cable according to its type (e.g., non-jacketed concentric neutral, jacketed shield wires, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield). Remove the outer jacket if applicable and ensure the cable insulation, semi-con shield, and tape marker are at the specified lengths (9-3/4”, 10-3/4”, 12-3/4” from the cut end, respectively). If using a grounding device or cable seal, refer to their specific instructions.

  4. Install Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed bare conductor should be between 4-1/4” – 4-9/16” (108mm-116mm). If the length is outside this range, redo the assembly.

  6. Crimp Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the “Check Dimension” before crimping; this dimension should be less than 6-3/8”. Crimp the compression lug following the crimping instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8” to 7-1/8” (162mm-181mm). If not, redo the assembly.

  7. Install Elbow

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  8. Prepare Mating Products

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZED WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not equipped with a stud. Clean and lubricate both the elbow and the mating part with the lubricant supplied, ensuring surfaces remain clean.

  9. Connect Elbow to Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect Second Mating Part (if applicable)

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with the mating part.

  11. Install Insulating Plug and Voltage Detection Cap (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow. Push down hard until the cap snaps into place. Follow the voltage test directions provided in the documentation.

  12. Ground the Cable Shield

    Insert one end of a wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop. Do not damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground according to the instructions supplied with the grounding device, or through an alternate method if no grounding device is used. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  13. Perform Final Torque Check (for 600amp L-Kits)

    CAUTION: When constructing 600amp L-Kits, be sure to tighten each component to the specified torque per the instructions provided.

  14. Perform Voltage Test

    The ELASTIMOLD® deadbreak elbow connector is equipped with an integral capacitance test point. To test, remove the test point cap with a hotstick, peeling off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false 'no voltage' indication. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.