ABB Installation Products J3-666-35-SV-N 3 Point Junction, with three 600 Amp Bushing Interfaces, 35kV, 6-1/2 inch centers. No…
UPC: 783786151790
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV rated junction box for medium-voltage applications
- Three 600 Amp bushing interfaces for high-current interconnections
- 6-1/2 inch center spacing for standard 35kV class compatibility
- No parking stand required, simplifying installation
- Suitable for indoor/outdoor use in switchgear and distribution systems
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Current Rating | 600 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Parking Stand |
Mounting Type | No Parking Stand |
Poles | 3P |
Size | Overall Length 17 inches, Width 6.75 inches |
Size | 6-1/2 inch centers |
Special Features | 6-1/2 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 3 Points |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-2266-35-N
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.
J5-22266-15-SV
5 Point Junction, with three 200 Amp Bushing Well Interfaces and two 600 Amp Bushing Interfaces, 15kV, 6-1/2 inch centers. No Tilt Mounting.
J5-22266-15
5 Point Junction, with three 200 Amp Bushing Well Interfaces and two 600 Amp Bushing Interfaces, 15kV, No Tilt Mounting.
J5-22226-15-SV
5 Point Junction, with four 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 15kV, 6-1/2 inch centers. No Tilt Mounting.
J5-62226-25
5 Point Junction, with one 600 Amp Bushing Interfaces, three 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interfaces, 25kV, No Tilt Mounting.
J6-666666-15-SV
6 Point Junction, six - 600 Amp Bushing interface, 15KV, SV - Optional 6-1/2 inch spacing, with Bracket
J6-222622-15-TMA
6 Point Junction, with three 200 Amp Bushing Well Interfaces, one 600 Amp Bushing Interface and two 200 Amp Bushing Well Interface, 15kV, Tilt Mounting Adapter.Frequently Asked Questions
What interface spacing options are available?
The junctions are available with standard 4'' spacing or optional 6.5'' spacing.
What are the main specifications of the junction?
The JX-XXXXXX-XX is a 15/25/35kV, 200/600 Amp molded multipoint junction. It features a fully shielded, submersible rubber housing.
What connectors are compatible with these junctions?
The junctions provide mating for Elastimold Elbow connectors. Both 600 Amp and 200 Amp Elastimold Elbow connectors are compatible.
What are the typical applications for ELASTIMOLD junctions?
ELASTIMOLD junctions are designed for subsurface, vault, or padmount applications. They can be used for sectionalizing, looping, tapping, and equipment bypass.
What modular design options are available for the junctions?
Units offer modular design flexibility, allowing selection of 200A deepwell or 600A bushing interfaces. These interfaces can have 4'' or 6.5'' spacing.
Which industry standards do these junctions meet?
The junctions meet ANSI/IEEE Standard 386, Latest Revision.
What is the maximum operating voltage for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the maximum operating voltage for the 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What is the maximum operating voltage for the 35kV class?
For the 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.
What are the continuous current ratings for the junctions?
The junctions have continuous current ratings of either 600 Amp or 200 Amp.
How to Install Elastimold Deadbreak Junctions (Universal Mount)
This guide provides step-by-step instructions for installing Elastimold two-, three-, or four-point deadbreak junctions using the universal mount configuration, including mounting, assembly, and initial grounding procedures. Ensure all apparatus is de-energized before beginning installation.
Estimated time: 1h
Tools needed:
Wrench or Socket Set, Drill (if using screws for fasteners), Measuring Tape or Ruler, Wire Strippers
Supplies needed:
Elastimold Deadbreak Junction (J2, J3, or J4 series), Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (includes 3/8" and 1/2" hex head cap screws, lock washers, hex nuts), Suitable Fasteners (for attaching universal brackets to surface), Grounding Wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (for unused bushings)
- De-energize Apparatus and Prepare Site
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Determine the desired location for the junction assembly. Using the base plate as a template, place it on the mounting surface and mark all four slot locations for the universal brackets.
- Mount Initial Universal Brackets
Attach two universal brackets to the marked slot locations on the flat surface using suitable fasteners (supplied by the user). Tighten these fasteners securely to prevent any movement during operation.
- Attach Remaining Universal Brackets
Connect the remaining two universal brackets to the two brackets already mounted on the surface. Position them at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten securely.
- Assemble Junction to Base Bracket and Plate
Secure the deadbreak junction to the base bracket assembly and base plate. Use two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Tighten securely.
- Mount Junction Assembly to Universal Brackets
Attach the assembled deadbreak junction, base bracket, and base plate to the universal brackets mounted on the surface. Use the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Ensure the parking stand is in the upright position and tighten all hardware securely.
- Ground the Junction Assembly
Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket. Ensure the base bracket assembly and the junction’s black conductive jacket are properly grounded.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate them with an ELASTIMOLD approved lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product or its mating product(s).
- Install Insulated Caps
If not all operating interfaces will be utilized, install appropriate HV insulated caps on the unused bushing(s) before energizing the circuit. Do not use the protective shipping caps for this function, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.