Contact for Pricing
Overview
- 15kV Voltage Rating
- One 200 Amp Bushing Well Interface
- Two 600 Amp Bushing Interfaces
- Stainless Steel Brackets
- Right Parking Stand Mounting
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | Right Mounting Bracket |
Size | Overall Length 16.5 inches, Width 6.75 inches |
Special Features | Right Parking Stand, Multi-Point Junction - 3 Points |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 3 Points |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-6226-15
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, No Tilt Mounting.
J4-2266-35-N
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.
J5-22226-25
5 Point Junction, four - 200 Amp Bushing Well interfaces, one - 600 Amp Bushing interface, 25/28KV, Standard 4 inch Center Spacing, No Tilt Mounting
J3-626-25-SV
3 Point Junction, with one 600 Amp Bushing Interface, one 200 Amp Bushing Well Interface and one 600 Amp Bushing Interface, 25kV, SV - Optional 6-1/2 inch Centers.
M656CH-DP0596699
600 Amp, 35kV, 4-Way Insulated Bus Bar with Test Point. (1) P0410 - Cable Insulation Diameter P - 1.725 to 1.935 inch, Aluminum Lug for 1000 Stranded/Compressed kcmil. (1) M0330 - Cable Insulation Diameter M - 1.370 to 1.630 inch, Aluminum Lug for 500 Stranded/Compressed kcmil or 600 Solid/Compact kcmil. (2) J0240 - Cable Insulation Diameter J - 0.980 to 1.180 inch, Aluminum Lugs for 1/0 Stranded/Compressed AWG or 2/0 Solid/Compact AWG.
K650T1-SP
15/25kv, 600 Amp, 8-9/16 inch Long Shank Bushing, Suffix SP for Permanent Stud, Entire Length 13.75 inches, Diameter 4.50 inches.Frequently Asked Questions
Is the junction housing submersible?
Yes, the molded rubber housing is fully shielded and fully submersible.
How many points can a junction have?
The junctions are available with 2, 3, 4, 5, or 6 points.
What are the continuous current ratings?
The junctions have continuous current ratings of either 200 Amp or 600 Amp.
What is the 35kV class maximum operating voltage?
For the 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.
What is the 25kV class maximum operating voltage?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What is the 15kV class maximum operating voltage?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What types of connectors are compatible?
The junctions provide mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.
What are the available interface spacing options?
Units are available with standard 4 inch spacing or optional 6.5 inch spacing.
What types of interfaces are available?
The junctions offer 200 Amp deepwell or 600 Amp bushing interfaces.
What standards do these junctions meet?
These junctions meet ANSI/IEEE Standard 386, Latest Revision.
How to Install the J3-266-15-R Deadbreak Junction (Universal Mount)
This guide provides step-by-step instructions for installing the J3-266-15-R two-, three-, or four-point deadbreak junction using the universal mounting method. It covers mounting, assembly, grounding, and preparation for operation procedures.
Estimated time: 1h
Tools needed:
Wrench, Wire strippers, Marking tool
Supplies needed:
Suitable Fasteners (for mounting brackets to surface), Grounding Wire (No. 2 solid to 1/0 stranded), HV Insulated Caps (if unused interfaces), ELASTIMOLD Approved Lubricant
- De-energize Apparatus and Prepare Site
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Determine the desired location for the junction assembly. Using the base plate as a template, place it on the mounting surface and mark all slot locations for the universal brackets.
- Mount Universal Brackets
Attach two universal brackets to the marked slot locations on the flat surface using suitable fasteners. Tighten the fasteners securely to prevent any movement during operation. Attach the remaining two universal brackets to the two brackets already mounted on the surface at the desired angle using the supplied hardware (3/8” hex head cap screw, external tooth lock washer, and 3/8” hex nut). Tighten these connections securely.
- Assemble and Mount Deadbreak Junction
Assemble the deadbreak junction to the base bracket assembly and base plate using two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts. Attach them to the center mounting holes on the bracket assembly. Tighten these components securely. Attach the complete deadbreak junction assembly to the universal brackets using the supplied hardware (1/2” hex head cap screw, 1/2” split lock washer, and 1/2” hex nut). Ensure the parking stand is in the upright position and tighten all connections securely.
- Ground the Junction Assembly
Ground the base bracket assembly and the junction’s black conductive jacket. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket for this purpose.
- Prepare for Operation
Remove all protective shipping caps from the operating interfaces. Clean each operating interface thoroughly. Lubricate each interface with an ELASTIMOLD approved lubricant. DO NOT SUBSTITUTE other lubricants, as they may harm the product or its mating parts. If any operating interfaces are not utilized, install appropriate HV insulated caps on these unused bushings before energizing the circuit. Do not use the protective shipping caps for this function, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.