- 15kV rated medium-voltage junction box
- Three bushing interfaces: 200A, 600A, 200A
- No tilt mounting hardware included
- Compatible with ABB bushing interfaces and accessories
- Designed for utility, industrial, and commercial applications
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Connection Type | Bushing Well interface |
Current Rating | 200 A / 600 A / 200 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Tilt Mounting Bracket |
Mounting Type | No Tilt Mounting |
Series | 3 Point Junction |
Size | Overall Length 19 inches, Width 6-3/4 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 3 Points |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 1 IN x 1 IN x 1 IN |
Package Dimensions (L x W x H) | 2.54 cm x 2.54 cm x 2.54 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-6226-15-L
4 Point Junction, with one 200 Amp Bushing Well Interface, two 600 Amp Bushing interfaces and one 200 Amp Bushing Well Interface, 15kV, Left Parking Stand.
J3-226-25-SV-N
3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 25kV, 6-1/2 inch centers. No Parking Stand.
J3-262-25-SV
3 Point Junction, with one 200 Amp Bushing Well Interface, one 600 Amp Bushing Interface and one 200 Amp Bushing Well Interface, 25kV, 6-1/2 inch centers. No Tilt Mounting.
J3-226-25
3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 25kV, No Tilt Mounting.
J3-226-15
3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 15kV, No Tilt Mounting.
J5-22222-15-L
15 kV Multi-point Junction, Left Parking Stand, five 200 Amp Bushing Well Interfaces. No Tilt Mounting
J3-266-15-N
3 Point Junction, with one 200 Amp Bushing Well Interface and two 600 Amp Bushing Interface, 15kV, No Parking Stand.Frequently Asked Questions
What are the voltage classes for these junctions?
The junctions are available in 15kV, 25kV, and 35kV voltage classes.
What is the maximum operating voltage for a 15kV class junction?
For a 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the rule for mixing 200 Amp and 600 Amp interfaces?
When mixing a 200 Amp interface and a 600 Series interface, always start with the 200 Amp side.
What are the options for mounting brackets?
Options include no tilt mounting bracket or a Tilt Mounting Adapter (TMA) for adjustable angles of 15, 30, 45, or 60 degrees.
How many points can a multipoint junction have?
Multipoint junctions are available with 2, 3, 4, 5, or 6 points.
What is included in a standard junction kit?
Each kit contains a basic molded junction, mounting hardware, lubricant tubes, installation instructions, and a protective cap.
What is the maximum operating voltage for a 35kV class junction?
For a 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.
What is the maximum operating voltage for a 25kV class junction?
For a 25kV voltage class, the maximum phase-to-ground operating voltage is 16.2kV.
What are the available interface spacing options?
Units feature a modular design allowing selection of 4'' or 6.5'' interface spacing.
What connectors are compatible with these junctions?
The junctions provide mating for Elastimold Elbow connectors, both 600 Amp and 200 Amp.
How to Install a Deadbreak Junction with Universal Mount
This guide provides detailed instructions for installing a two-, three-, or four-point deadbreak junction using the universal mounting method. It covers site preparation, bracket assembly, junction mounting, and essential grounding procedures.
Estimated time: 1h 30m
Tools needed:
Wrenches, Wire Strippers, Measuring Tape, Marking Tool
Supplies needed:
Deadbreak Junction Kit (including Base Bracket, Base Plate, Universal Brackets, Mounting Hardware Prepack), Fasteners (suitable for mounting brackets to surface), Grounding Wire (No. 2 solid to 1/0 stranded), ELASTIMOLD Approved Lubricant, HV Insulated Caps (for unused interfaces)
- De-energize Apparatus and Ensure Safety
Before beginning installation, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Determine Mounting Location and Mark Slots
Select the desired location for the junction assembly. Use the base plate as a template, place it on the mounting surface, and accurately mark all slot locations for drilling or fastener placement.
- Attach Initial Universal Brackets to Surface
Secure two (2) universal brackets to the marked flat surface using suitable fasteners. Tighten these fasteners securely to prevent any movement of the brackets during operation.
- Assemble Remaining Universal Brackets
Attach the remaining two (2) universal brackets to the two brackets already mounted on the surface at the desired angle. Use the supplied hardware (3/8” hex head cap screw, external tooth lock washer, 3/8” hex nut) and tighten securely.
- Assemble Junction to Base Bracket and Base Plate
Connect the deadbreak junction to the base bracket assembly and base plate. Use two (2) 1/2” hex head cap screws, two (2) 1/2” split lock washers, and two (2) 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Ensure all connections are securely tightened.
- Attach Junction Assembly to Universal Brackets
Mount the assembled deadbreak junction to the universal brackets using the supplied hardware (1/2” hex head cap screw, 1/2” split lock washer, 1/2” hex nut). Tighten all fasteners securely. Verify that the parking stand is in the upright position.
- Ground the Base Bracket and Junction Jacket
Ground the base bracket assembly and the junction’s black conductive jacket. A grounding lug is provided on the base bracket for this purpose, accommodating wire sizes from No. 2 solid to 1/0 stranded. Connect the appropriate grounding wire securely.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate them with an ELASTIMOLD approved lubricant. Do not substitute with other lubricants, as they may harm the product.
- Install Insulated Caps on Unused Bushings
If any operating interfaces are not utilized, install appropriate HV insulated caps on these unused bushings before energization. Do not use the protective shipping caps for this function, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.