- 35kV-rated 3-point junction for medium-voltage distribution systems
- Two 200 Amp and one 600 Amp bushing well interfaces for versatile load connections
- Integrated tilt mounting adapter for flexible installation in constrained spaces
- Supports 3-phase input and output configurations
- Designed for transformers, switchgear, and critical power distribution components
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Connection Type | Bushing Well interface |
Current Rating | 200A, 200A, 600A |
Current Rating | 200 A / 600 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | Tilt Mounting Adapter |
Mounting Type | Tilt Mounting Adapter |
Series | J3 |
Size | Overall Length 19 inches, Width 6-3/4 inches |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 3 Points |
Voltage Rating | 35kV |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 1 IN x 1 IN x 1 IN |
Package Dimensions (L x W x H) | 2.54 cm x 2.54 cm x 2.54 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-2266-35-N
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.
J6-222222-25-SV
6 Point Junction, six - 200 Amp Bushing Well interface, 25KV, SV - Optional 6-1/2 inch spacing, with Bracket
J5-6BB66-15
5 Point Junction, one - 600 Amp Bushing interface, two - Blank position, two - 600 Amp Bushing interface, 15KV, with Bracket
J3-226-15-SV-N
3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 15kV, 6-1/2 inch centers. No Parking Stand.
J3-226-15-SV
3 Point Junction, with two 200 Amp Bushing Well Interfaces and one 600 Amp Bushing Interface, 15kV, 6-1/2 inch centers. No Tilt Mounting.
J6-222666-15
6 Point Junction, three - 200 Amp Bushing Well interface, three - 600 Amp Bushing interface, 15KV, with Bracket
J6-222666-15-TMA
6 Point Junction, three - 200 Amp Bushing Well interface, three - 600 Amp Bushing interface, 15KV, with Bracket, TMA - Tilt Mount Adapter
J6-226666-25-SV
6 Point Junction, two - 200 Amp Bushing Well interface, four - 600 Amp Bushing interface, 25KV, SV - Optional 6-1/2 inch spacing, with BracketFrequently Asked Questions
What connectors are compatible with this junction?
The junction provides mating for both 600 Amp and 200 Amp Elastimold Elbow connectors.
Where can these junctions be installed?
ELASTIMOLD junctions are designed for subsurface, vault, or padmount applications.
What are the voltage and continuous current ratings?
The multipoint junction is rated for 15/25/35kV. Continuous current ratings are 200 Amp or 600 Amp.
What are the primary applications of these junctions?
They can be used for sectionalizing, looping, tapping, and equipment bypass.
What interface options and spacings are available?
The units offer modular design flexibility with 200A deepwell or 600A bushing interfaces, available with 4 in or 6.5 in spacing.
What is the 15kV class operating voltage?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV.
What is the 25kV class operating voltage?
For the 25kV class, the maximum phase-to-ground operating voltage is 16.2kV.
What is the Tilt Mounting Adapter option?
The Tilt Mounting Adapter provides 15, 30, 45, or 60 degree adjustable angles when bolted to the standard mounting bracket. Two adapters are required.
What is the 35kV class operating voltage?
For the 35kV class, the maximum phase-to-ground operating voltage is 21.1kV.
What items are included in each kit?
Each kit contains a basic molded junction, mounting hardware, two tubes of lubricant, installation instructions, and a protective cap.
How to Install a Deadbreak Junction with Universal Mount
This guide provides step-by-step instructions for installing a two-, three-, or four-point deadbreak junction using the universal mount method, including initial setup and grounding procedures.
Estimated time: 2h
Tools needed:
Wrench set, Socket set, Wire strippers, Marking tool, Drill (if needed for fasteners)
Supplies needed:
Deadbreak Junction, Base Bracket, Base Plate, Universal Brackets (4), Mounting Hardware Prepack (includes various screws, washers, nuts), Suitable fasteners (for mounting brackets to surface, user-supplied), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, Insulated caps (for unused bushings)
- Mark Mounting Locations
DANGER: All apparatus must be de-energized during installation. Select the desired mounting location for the junction assembly. Use the base plate as a template to mark the slot locations on the flat mounting surface.
- Secure Initial Universal Brackets
Attach two universal brackets to the marked locations on the flat mounting surface using suitable fasteners (user-supplied). Tighten them securely to prevent any movement during operation.
- Assemble Remaining Universal Brackets
Connect the remaining two universal brackets to the previously mounted brackets at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Ensure all connections are tightened securely.
- Attach Junction to Base Assembly
Assemble the deadbreak junction to the base bracket assembly and base plate. Secure them together using two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts through the center mounting holes. Tighten these fasteners securely.
- Mount Junction Assembly to Universal Brackets
Mount the assembled deadbreak junction and base bracket to the universal brackets using the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Tighten all connections securely. Verify that the parking stand is in the upright position.
- Ground the Junction Assembly
The base bracket assembly and the junction’s black conductive jacket must be grounded. Connect a grounding wire (No. 2 solid to 1/0 stranded) to the grounding lug provided on the base bracket and ensure it is securely attached to an earth ground.
- Prepare and Lubricate Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and then lubricate them with an ELASTIMOLD approved lubricant. Do not use substitute lubricants, as they may damage the product or its mating parts.
- Install Insulated Caps on Unused Bushings
If any operating interfaces are not going to be utilized, install appropriate insulated caps on these unused bushing(s) before energizing the circuit. Do not use the protective shipping caps for this function, as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.