ABB Installation Products J2-66-35 35kV, 600 Amp, Multi-Port Junction, 2 Points, 2 X 600 Amp Bushing Interfaces, No Tilt…
UPC: 075114295147
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV rated voltage for medium-voltage distribution systems
- 600 Amp continuous current rating with dual 600A bushing interfaces
- Standard 4-inch center spacing for compatibility with existing installations
- No-tilt mounting design for vertical or horizontal orientation flexibility
- UNSPSC 26121630 compliant for industrial and utility applications
Specifications
Application | Suited for Subsurface, Vault or Padmount Applications and can be used for Sectionalizing, Looping, Tapping and Equipment Bypass |
Connection | Push-In |
Connection Type | Bushing Interfaces |
Current Rating | 600 A |
Material | EPDM-Rubber and Stainless Steel Mounting Brackets |
Mounting | No Tilt Mounting Bracket |
Mounting Type | No Tilt Mounting |
Poles | 2 |
Series | J2 |
Size | Overall Length 15 inches, Width 6-3/4 inches |
Size | 4 inch Centers |
Special Features | 4 inch Center Spacing |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Multi-Point Junction - 2 Points |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-2266-35-N
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.
J6-666666-15-N
25kV, Multi-Port Junction, 6 Points, Six 600 Amp Bushing Interface, Standard Spacing - 4 inch Centers, No Parking Stand
J5-22226-15-N
15kV, Multi-Port Junction, 5 Points, Four 200 Amp Bushing Well Interfaces, and One 600 Amp Bushing Interface, No Parking Stand, Standard Spacing - 4 inch Centers
J6-622226-35-TMA
35 kV, 6 Pont Multi-Point Junction, 1 X 600 Amp Bushing Interface, 4 X 200 Amp Bushing Well Interface, 1 X 600 Amp Bushing Interface, Standard Spacing on 4 inch Centers, Tilt Mounting Adapter
J6-222622-25
25kV, Multi-Port Junction, 6 Points, Three 200 Amp Bushing Well Interfaces, One 600 Amp Bushing Interface, Two 200 Amp Bushing Well Interfaces, Standard Spacing - 4 inch Centers, No Tilt Mounting
J5-22222-35-TMA
5 Points, Molded Multi-Point Junction, 5 x 200 Amp Bushing Well Interfaces, 35kv, Standard Interface Spacing of 4 inches, with Tilt Mounting Adapter.
J5-22666-15-N
Molded Multi-Point Junction, 5 Points, Two 200 Amp Bushing Well Interfaces, Three 600 Amp Bushing Interfaces, Voltage Class 15kV, Standard 4 inch Interface Spacing, No Parking StandFrequently Asked Questions
What are the voltage and current ratings?
The junctions are rated for 15kV, 25kV, or 35kV voltage classes, and either 200 Amp or 600 Amp continuous current.
What are the continuous current ratings?
The junctions are rated for either 200 Amp continuous or 600 Amp continuous current.
What are the available parking stand options?
Parking stand options include Left parking stand only, Right parking stand only, or No parking stand.
Are there options for mounting brackets?
Yes, options include no tilt mounting bracket or a Tilt Mounting Adapter for adjustable angles of 15, 30, 45, or 60 degrees.
What types of interfaces are available for selection?
Available interfaces are 200 Amp Deepwell, 600 Amp Bushing, or a Blank Position.
How many points can a multipoint junction have?
Multipoint junctions are available with 2, 3, 4, 5, or 6 points.
What is included in a standard junction kit?
Each kit contains the basic molded junction, mounting hardware, lubricant tube, installation instructions, and a protective cap.
What is the impulse withstand rating (BIL) for each voltage class?
The BIL is 95kV for 15kV class, 140kV for 25kV class, and 150kV for 35kV class.
What are the maximum operating voltages for each class?
Max phase-to-ground operating voltages are 8.3kV for 15kV class, 16.2kV for 25kV class, and 21.1kV for 35kV class.
What are the available interface spacing options?
Units offer modular design flexibility with either standard 4-inch spacing or optional 6.5-inch spacing.
How to Install J2-66-35 Deadbreak Junction with Universal Mount
This guide provides step-by-step instructions for installing a J2-66-35 deadbreak junction using the universal mount method. It covers mounting, assembly, grounding, and initial preparation for operation.
Estimated time: 45m
Tools needed:
Wrenches or Sockets (for 3/8" and 1/2" hex nuts/cap screws), Wire strippers
Supplies needed:
J2-66-35 Deadbreak Junction, Universal Mount Kit (includes Base Bracket, Base Plate, 4 Universal Brackets, Mounting Hardware Prepack), Fasteners (suitable for mounting universal brackets to your surface), Grounding wire (No. 2 solid to 1/0 stranded), ELASTIMOLD approved lubricant, HV insulated caps (for any unused operating interfaces)
- De-energize All Apparatus
DANGER: Before beginning any installation, ensure all apparatus is de-energized. All deadbreak connectors must be de-energized before operating. Failure to follow this instruction can result in damage to the product and serious or fatal injury.
- Mark Mounting Locations
Determine the desired location for the junction assembly on a flat surface. Place the base plate on the surface and use it as a template to accurately mark the slot locations where the universal brackets will be attached.
- Mount Universal Brackets
Attach two universal brackets to the marked slot locations on the flat surface using suitable fasteners and tighten them securely to ensure no movement during operation. Next, attach the remaining two universal brackets to the first pair at the desired angle using the supplied 3/8” hex head cap screws, external tooth lock washers, and 3/8” hex nuts. Tighten all connections securely.
- Assemble and Mount Junction
Connect the deadbreak junction to the base bracket assembly and base plate using two 1/2” hex head cap screws, two 1/2” split lock washers, and two 1/2” hex nuts, attaching them to the center mounting holes on the bracket assembly. Then, attach this entire junction assembly to the universal brackets using the supplied 1/2” hex head cap screws, 1/2” split lock washers, and 1/2” hex nuts. Ensure the parking stand is in the upright position before tightening all hardware securely.
- Ground the Junction Assembly
Connect a suitable grounding wire to the grounding lug provided on the base bracket. This lug accommodates wire sizes from No. 2 solid to 1/0 stranded. Ensure both the base bracket assembly and the junction’s black conductive jacket are properly grounded.
- Prepare Operating Interfaces
Remove all protective shipping caps from the operating interfaces. Clean each interface thoroughly and lubricate them with an ELASTIMOLD approved lubricant; do not substitute other lubricants. If any operating interfaces are not utilized, install appropriate HV insulated caps on the unused bushings before energizing the circuit. Do not use the protective shipping caps for this function as they are not insulated.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.