ABB Installation Products ESP313-BBJ-222 Multi-Way, Single-Sided Padmount, 15 kV/12.5 kA, 3 Junctions, 3-Point Junction, Point 1…
UPC: 075114414111
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15 kV voltage rating with 12.5 kA interrupting capacity
- Three junction points: two 200 Amp bushing wells and one 1-Phase MVI with 200 Amp interface
- Fully shielded, submersible design for energized operation
- Compatible with ELASTIMOLD 375LR, 376LR, 370GLR, and 370TR accessories
- Universal mounting brackets for curved/flat surfaces with 0°–90° tilt adjustment
Specifications
Amperage Rating | 200 A |
Application | Single Side Padmount |
Connection Type | Bushing Well / MVI |
Current Rating | 12.5 kA |
Material | Elastimold |
Mounting Type | Padmount |
Phase | 3 Phase |
Poles | 3 |
Size | 84 in x 42 in x 30 in |
Special Features | 3-Way |
Type | Multi Way Switch |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

ESS-CONN-MOD-KIT
15kV & 27kV Jumper Cable and Connector Plate Kit (3 jumper cables, 4 connector plates, stabilizer plate & hardware)
ESS322-V-66-MOD
Multi-Way Switch, Type SubSurface, Three-Phase, 27kV, 2 Way, Three-Phase MVS with 120VAC Motor, 600 Amp Terminations, Modular
TD3132H1P66AIEXAE000
Automatic Transfer Double-Sided Padmount, Three-phase 15kV, 95KS BIL, Three-ways, Galvanized Steel Enclosure, Round Ground Bar
ESP114-BJJB-2222
Multi-Way Switch, Single-Sided Padmount, 1 Phase, 15 kV Nominal, 4-Point Junction, Junction 1: 200 Amp Bushing-Well Interface, Junction. 2: MVI1 with 200 Amp Main-Body Bushing, Junction. 3: MVI1 with 200 Amp Main-Body Bushing, Junction. 4: 200 Amp Bushing-Well. Control: Elastimold Internal Control. Enclosure: Galvanized Steel, Paint: Padmount Green. B - Solid Tap / Bus Connection, J - 1-Phase Fault Interrupter
MD3121T-1149462
Multiway, Double-Sided Padmount, 15kV/12.5kA, 1-Source Component: MVS3 with 600 Amp Accessories: Tru-Break with DC Interlock (Source Ways), Galvanized Steel, English Labels and Instructions
MP3142T-1150044
Multiway, Single-Sided Padmount, 15kV/12.5kA, 4-Ways, 2-Source Ways, Source Component: MVS3 with 600 Amp Bushings, Source Control: None, 2-Load Ways, Load Component: (3) MVI1's with 200 Amp Bushing Wells, Load Control: Elastimold 80 Control, Enclosure: Stainless Steel, Munsell Green 7GY 3.29/1.5 and Round Ground Bar, English Labels and Instructions
MP3142T-1150043
Multiway, Single-Sided Padmount, 15kV/12.5kAa, 4-Ways, 2-Source Ways, Source Component: MVS3 with 200 Amp Bushing Wells, Source Control: None, 2-Load Ways, Load Component: (3) MVI1's with 200 Amp Bushing Wells, Load Control: Elastimold 80 Control, Enclosure: Stainless Steel, Munsell Green 7GY 3.29/1.5 and Round Ground Bar, English Labels and Instructions
ESP314-BBJB-6626
Multi-Way Switch, Single-Sided Padmount, 15kV, 3-Phase, (3) Sets of 4-Point Junctions, (Left to Right). Junction 1: 600 Amps Solid Tap, Junction 2: 600 Amps Solid Tap, Junction 3: MVI1 with 200 Amps Main-Body Interface, Junction 4: 600 Amps Solid Tap. Cabinet Depth 54 Inch, Mile Steel Enclosure Material.How to Install Switchgear Cabinets
This guide provides general recommendations and procedures for the safe and proper installation of switchgear junction and padmount cabinets, including pre-installation checks, lifting, mounting, and grounding.
Estimated time: 2h
Tools needed:
Lifting eyebolts, Lifting cables, Torque wrench, Screwdriver, Measuring tape, Level
Supplies needed:
1/2-13 anchors, Holdown brackets, Suitable lifting straps, Protective covers, Grounding system components, Mounting cleats
- Perform Pre-Installation Checks
Carefully review all installation instructions. Verify the switchgear nameplate matches requirements. Confirm the concrete pad or structure is adequate for the switchgear's size and weight. Check all anchor dimensions. Ensure the grounding system is properly installed according to NEC, ANSI/IEEE, etc. Verify all main connections are made in accordance with instructions. Inspect doors and locks for correct operation and any imperfections. Confirm all switchgear parts are in good condition; contact T&B if not. Perform a detailed physical inspection for mechanical and electrical integrity. Apply mechanical torque to all switchgear hardware and electrical connections according to recommended values. Safety Warning: All cable connections MUST be installed under de-energized and grounded conditions.
- Unpackage and Prepare for Lifting
Remove the top of the packaging box from the base. Remove any 1/2-13 mounting hardware securing the unit within the packaging. Assemble four 1/2-13 lifting eyebolts (customer supplied) to the top of the side panels. Attach lifting cables to the eyebolts, ensuring cables are not crossed over the unit. Safety Warning: If the switch is not installed immediately and is stored outside, use protective covers.
- Lift and Mount the Switchgear Cabinet
Caution: Follow all locally approved safety practices when lifting. Use the recessed lifting provisions provided at the four corners of the switchgear housing. Use suitable lifting straps to prevent damage to the switchgear. Close and lock the cabinet doors before lifting to prevent twisting or "racking" of the cabinet. Lift the unit smoothly and do not allow it to shift. Caution: Never place jacks, tackle, or other attachments under the unit for lifting purposes. Mount the switchgear cabinet onto a level concrete pad or structure designed to support its size and weight.
- Anchor the Switchgear Cabinet
For vault mounting, anchor the switchgear framework to the floor using the four holdown brackets (customer supplied) and 1/2-13 anchors (customer supplied) to the specified dimensions. For padmount mounting, anchor the enclosure to the concrete pad using the four supplied holdown brackets and 1/2-13 anchors (customer supplied) to the specified dimensions. Brackets may be rotated 90 degrees if needed. Alternatively, use mounting cleats provided or other suitable mounting hardware.
- Ground the Switchgear
Install a permanent, low-resistance ground connection to the switchgear assembly. Grounding provisions are provided near the bottom of the switchgear assembly. Safety Warning: Solidly ground all equipment. Failure to comply can result in death, severe personal injury, and equipment damage.
- Secure and Finalize Installation
Close and lock all switchgear doors to prevent unauthorized access and accidental contact with high voltage. Perform any final checks as per the manufacturer's complete installation instructions (which are noted to be provided with the equipment).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.