Authorized ABB Distributor (Installation Products)
ABB - Installation Products AL 600 NTN - Tin Plated Aluminum Two-Hole NEMA Lugs - straight lug, 600 kcmil AL9CU and 550 kcmil and ACSR 477 (26/7) and 556.5 (18/1), installing dies 1 5/16, 115H, 786, 936, 473. Length 7-3/4 inch. Pad 1-3/4 inch wide x 3-5/8 inch long x 1/2 inch thick. (2) 9/16 inch diameter holes on 1-3/4 centers. Barrel 2-15/16 inch x 1-7/16 inch outside Diameter. Oxide Inhibitor. Black Cap.

ABB Installation Products AL 600 NTN Tin Plated Aluminum Two-Hole NEMA Lugs - straight lug, 600 kcmil AL9CU and 550 kcmil and…

UPC: 783786693979


Documents & Media
Manufacturer Product Website

Contact for Pricing

Minimum Qty: 25

Multiplier: 25

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB AL 600 NTN tin-plated aluminum two-hole NEMA lugs are designed for terminating 600 kcmil AL9CU and 550 kcmil conductors, including ACSR 477 (26/7) and 556.5 (18/1) cables. The lug features a straight design with a 7-3/4 inch length, 1-3/4 inch wide x 3-5/8 inch long pad, and 1/2 inch thickness. It includes two 9/16 inch diameter holes on 1-3/4 inch centers for secure mounting. The barrel measures 2-15/16 inch x 1-7/16 inch outside diameter, ensuring compatibility with standard installation dies (1 5/16, 115H, 786, 936, 473). The tin plating provides corrosion resistance, while the oxide inhibitor enhances long-term performance. The black cap protects the connection during storage and transport. These lugs are ideal for industrial, utility, and commercial electrical installations requiring reliable, high-current terminations. The lug’s dimensions and material composition make it suitable for heavy-duty applications where durability and conductivity are critical. The oxide inhibitor ensures minimal resistance at the termination point, reducing heat buildup and extending service life. The black cap also serves as a visual indicator of proper installation and protection against environmental contaminants.
  • Tin-plated aluminum construction for corrosion resistance
  • Designed for 600 kcmil AL9CU and 550 kcmil conductors
  • Compatible with ACSR 477 (26/7) and 556.5 (18/1) cables
  • 7-3/4 inch length with 1/2 inch thick pad
  • Includes oxide inhibitor and black protective cap

Specifications

Application
General purpose lugs for Aluminum and Copper terminations
Connection
Compression
Finish
Tin Plated
Housing Material
Aluminum
Housing Material
Aluminium
Size
Length 7-3/4 inches
Special Features
Dual-rated. Use with Aluminum and Copper conductors. Prefilled with oxide inhibitor to prevent oxidation and keep out moisture. All lugs marked with conductor sizes and die reference for easy identification
Standard
ANSI C119.4
Type
Compression Lug Two Hole
Wire Size
600 kcmil
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.7200 L
Package Weight (Metric)
0.3270 kg
Tin Plated Aluminum Compression Lug for Aluminum and Copper Terminations, Two-Hole NEMA Pad, Wire Range 600 kcmil Stranded AL-CU. Installing dies 140H, 301, 342, 724, 1 1/2, 39ART. Length 8-9/16 inch. Pad 1-19/32 inch wide x 3-21/32 inch long x 9/16 inch thick, (2) 9/16 inch diameter holes on 1-3/4 inch center, uses 1/2 inch Bolt. Barrel 3-19/32 inch. Oxide Inhibitor. Black Cap.

SAL 600 NTN

Tin Plated Aluminum Compression Lug for Aluminum and Copper Terminations, Two-Hole NEMA Pad, Wire Range 600 kcmil Stranded AL-CU. Installing dies 140H, 301, 342, 724, 1 1/2, 39ART. Length 8-9/16 inch. Pad 1-19/32 inch wide x 3-21/32 inch long x 9/16 inch thick, (2) 9/16 inch diameter holes on 1-3/4 inch center, uses 1/2 inch Bolt. Barrel 3-19/32 inch. Oxide Inhibitor. Black Cap.
The Polaris IPLMD350-6 Multi-Tap Mountable Dual-Sided Entry Connector features 6 ports sized for 350 MCM - 6 AWG wires. Mounting holes on either side of the connector allow for direct mounting to troughs, panels or wireways with 1/4†bolts. The body is made from aluminum alloy wrapped in a layer of plastisol insulation. Each dual-sided port is pre-loaded with an oxide inhibitor, with removable access plugs over the hex screws used to tighten the connections. Installs with a hex key and torque wrench, without any tape or additional supplies. Designed for use in a wide range of splicing applications, including installation in cable trays, panel boards, ducts, raceways or troughs.

IPLMD350-6

The Polaris IPLMD350-6 Multi-Tap Mountable Dual-Sided Entry Connector features 6 ports sized for 350 MCM - 6 AWG wires. Mounting holes on either side of the connector allow for direct mounting to troughs, panels or wireways with 1/4†bolts. The body is made from aluminum alloy wrapped in a layer of plastisol insulation. Each dual-sided port is pre-loaded with an oxide inhibitor, with removable access plugs over the hex screws used to tighten the connections. Installs with a hex key and torque wrench, without any tape or additional supplies. Designed for use in a wide range of splicing applications, including installation in cable trays, panel boards, ducts, raceways or troughs.
Tin Plated Aluminum Two-Hole NEMA Lugs - straight lug, 750 kcmil AL9CU UL listed, installing dies 140H, 301, 342, 1 1/2. Using Die 1 1/2H 700 kcmil, 750 Compact, 900 Compact, 636(24/7), 636(26/7) ACSR, 721(18/1) 721(30/7) ACAR, 740.8 AAAC. Length 8-1/4 inch. Pad 1-3/4 inch wide x 3-3/4 inch long x 37/64 inch Minimum Thick. (2) 9/16 inch holes on 1-3/4 inch centers. Barrel 3-5/16 inch long x 1-19/32 inch outside diameter. Oxide Inhibitor. Red Cap.

AL 750 NTN

Tin Plated Aluminum Two-Hole NEMA Lugs - straight lug, 750 kcmil AL9CU UL listed, installing dies 140H, 301, 342, 1 1/2. Using Die 1 1/2H 700 kcmil, 750 Compact, 900 Compact, 636(24/7), 636(26/7) ACSR, 721(18/1) 721(30/7) ACAR, 740.8 AAAC. Length 8-1/4 inch. Pad 1-3/4 inch wide x 3-3/4 inch long x 37/64 inch Minimum Thick. (2) 9/16 inch holes on 1-3/4 inch centers. Barrel 3-5/16 inch long x 1-19/32 inch outside diameter. Oxide Inhibitor. Red Cap.
Tin Plated Aluminum Multi-Range Die-Less Lugs, 750 kcmil AL9CU UL Listed using Dies 125H, 608, 786, 936. 700 kcmil, 400 MM2, 636(26/7) ACSR. Can use VC 8 Tool for 500-750 kcmil AL-CU and 636(26/7). Length 8-1/4 inch. Pad 1-3/4 inch wide x 3-53/64 inch long x 15/32 inch thick. (2) 9/16 inch holes on 1-3/4 inch center. Barrel 3-3/8 inch long x 1-1/2 inch Outside Diameter. Oxide Inhibitor. Red Cap.

AL 750 N 608 TN

Tin Plated Aluminum Multi-Range Die-Less Lugs, 750 kcmil AL9CU UL Listed using Dies 125H, 608, 786, 936. 700 kcmil, 400 MM2, 636(26/7) ACSR. Can use VC 8 Tool for 500-750 kcmil AL-CU and 636(26/7). Length 8-1/4 inch. Pad 1-3/4 inch wide x 3-53/64 inch long x 15/32 inch thick. (2) 9/16 inch holes on 1-3/4 inch center. Barrel 3-3/8 inch long x 1-1/2 inch Outside Diameter. Oxide Inhibitor. Red Cap.
Tin Plated Aluminum Two-Hole NEMA Lugs - straight lug, 800 kcmil AL9CU UL listed, 400 MM2, installing dies 140H, 474, 342, 724, 1 1/2. Length 8-5/16 inch. Pad 1-3/4 inch wide x 3-5/8 inch long x 39/64 inch thick. (2) 9/16 inch diameter holes on 1-3/4 inch Centers. Barrel 3-11/32 inch long x 1-21/32 inch Outside Diameter. Oxide Inhibitor. Light Blue Cap.

AL 800 NTN

Tin Plated Aluminum Two-Hole NEMA Lugs - straight lug, 800 kcmil AL9CU UL listed, 400 MM2, installing dies 140H, 474, 342, 724, 1 1/2. Length 8-5/16 inch. Pad 1-3/4 inch wide x 3-5/8 inch long x 39/64 inch thick. (2) 9/16 inch diameter holes on 1-3/4 inch Centers. Barrel 3-11/32 inch long x 1-21/32 inch Outside Diameter. Oxide Inhibitor. Light Blue Cap.
Tin Plated Aluminum Two-Hole NEMA Lugs - Stacking Lug, Stranded 1 and 2, Compressed 1, Solid 1/0, ACSR 2. Bolt hole size 5/16 inch, installing dies TU, 52, BG, 243, 5/8. Length 5-3/16 inch. Pad 3/4 inch wide x 2-7/8 inch long x 17/64 inch thick. (2) 9/16 inch holes on 1-3/4 inch centers. Barrel 1-7/16 inch long x 41/64 inch Outside Diameter. Oxide Inhibitor. Red Cap. Dual Rated for use with Aluminum and Copper Conductors.

ASL 2 NTN

Tin Plated Aluminum Two-Hole NEMA Lugs - Stacking Lug, Stranded 1 and 2, Compressed 1, Solid 1/0, ACSR 2. Bolt hole size 5/16 inch, installing dies TU, 52, BG, 243, 5/8. Length 5-3/16 inch. Pad 3/4 inch wide x 2-7/8 inch long x 17/64 inch thick. (2) 9/16 inch holes on 1-3/4 inch centers. Barrel 1-7/16 inch long x 41/64 inch Outside Diameter. Oxide Inhibitor. Red Cap. Dual Rated for use with Aluminum and Copper Conductors.
Tin Plated Aluminum Two-Hole NEMA Lugs - stacking lug, 2/0 Stranded AL9CU - UL listed, bolt hole size 9/16 inch, installing dies TW-TY, 58, U26ART. Length 5-3/8 inch. Pad 15/16 inch wide x 3 inch long x 15/64 inch thick. (2) 9/16 inch holes on 1-3/4 inch centers. Barrel 1-11/16 inch long x 11/16 inch Outside Diameter. Oxide Inhibitor. Olive Cap.

ASL 2/0 NTN

Tin Plated Aluminum Two-Hole NEMA Lugs - stacking lug, 2/0 Stranded AL9CU - UL listed, bolt hole size 9/16 inch, installing dies TW-TY, 58, U26ART. Length 5-3/8 inch. Pad 15/16 inch wide x 3 inch long x 15/64 inch thick. (2) 9/16 inch holes on 1-3/4 inch centers. Barrel 1-11/16 inch long x 11/16 inch Outside Diameter. Oxide Inhibitor. Olive Cap.
Tin Plated Aluminum Two-Hole NEMA Lugs - Stacking lug, 4/0 Stranded AL9CU - UL listed, 250 Compact. Installing dies TX, 71H, W660, U28ART. Use VC 5 or VC 6 Tools for #2 - 4/0 Stranded. Length 5-59/64 inch. Pad 1-3/16 inch wide x 3 inch long x 19/64 inch thick. (2) 9/16 inch holes on 1-3/4 inch Centers. Barrel 1-15/16 inch long x 7/8 inch Outside Diameter. Oxide Inhibitor. White Cap.

ASL 4/0 NTN

Tin Plated Aluminum Two-Hole NEMA Lugs - Stacking lug, 4/0 Stranded AL9CU - UL listed, 250 Compact. Installing dies TX, 71H, W660, U28ART. Use VC 5 or VC 6 Tools for #2 - 4/0 Stranded. Length 5-59/64 inch. Pad 1-3/16 inch wide x 3 inch long x 19/64 inch thick. (2) 9/16 inch holes on 1-3/4 inch Centers. Barrel 1-15/16 inch long x 7/8 inch Outside Diameter. Oxide Inhibitor. White Cap.

Frequently Asked Questions

What are the hole dimensions for mounting?

The lug has two 9/16 inch diameter holes on 1-3/4 inch centers for secure attachment.

What is the barrel outside diameter?

The barrel measures 2-15/16 inch x 1-7/16 inch outside diameter.

What installation dies are compatible?

Compatible installation dies include 1 5/16, 115H, 786, 936, and 473.

What is the pad width and length?

The pad measures 1-3/4 inch wide x 3-5/8 inch long.

What conductor sizes does the AL 600 NTN support?

The AL 600 NTN supports 600 kcmil AL9CU, 550 kcmil, ACSR 477 (26/7), and 556.5 (18/1) conductors.

What is the purpose of the oxide inhibitor?

The oxide inhibitor prevents corrosion and ensures long-term electrical conductivity.

Is the AL 600 NTN suitable for outdoor use?

The tin plating and oxide inhibitor provide corrosion resistance, making it suitable for outdoor applications.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.