- 30 Amp current rating for robust power delivery
- 250 Volt voltage rating for industrial applications
- 3/4 inch NPT threading for secure and weather-resistant connections
- Durable construction for reduced downtime and maintenance
- Manufactured by ABB Installation Products in the USA
Specifications
Amperage Rating | 30 Amps |
Application | For use where electrical connections need protection from water and/or dust entrance to the contacts or the wiring compartment |
Connection Type | Female Connector |
Current Rating | 30 A |
Current Rating | 30 Amp |
Material | DuraV |
Number Of Poles | 2 |
Number Of Wires | 3 |
Series | DuraGard |
Size | 3/4 Inch NPT |
Size | 3/4" NPT |
Special Features | Not just "watertight", Waterproof for washdown duty (DurORing Sealing) that eliminates the need for costly "weather boots" or "adapters." |
Type | DuraGard Waterproof Connections |
Voltage Rating | 250 V |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.940 L |
Package Weight (Metric) | 0.426 kg |

ISE66
Pre-Insulated Service Entry Sleeves 3-4 Str -6 Sol Pre-insulated service entry sleeves are used for fast and easy installation with standard tools. For combinations of aluminum-aluminum and aluminum-copper conductors. Meets the requirements of ANSI C119.4. Rated 600 Volts.
DFRF34070
Maxgard Fused Male Plug Disconnect Interlocked Receptacle (Nema 12/3R), 30 Amp, 3 Pole 4 Wire, 30 250V, 60Hz
DF1516FRS00
Female Receptacle with Straight Adapter, Voltage 3 Phase Y 120/208V, Amperage 100A, 4 Poles 5 Wire, with Flap Cap
DF1404FRS00
Female Receptacle with Straight Adapter, Voltage 380V, Amperage 100A, 3 Poles 4 Wire, with Flap Cap
DF2407FP00K
Female Connector with Straight Adapter, Voltage 3 Phase 250V, Amperage 200A, 3 Poles 4 Wire, with Flap Cap and 2 Control ContactsHow to Install the 9C33U2/C75 DuraGard Plug, Receptacle, or Connector
Installation guide for mounting and wiring the 9C33U2/C75 DuraGard plug, receptacle, or connector in harsh environments.
Estimated time: 30m
Tools needed:
Torque Wrench, Screwdriver, Ohmmeter, Wire Strippers, Allen Wrench, 3/16" Dia. Drive Pin (optional), Channel lock pliers
Supplies needed:
Copper or copper clad aluminum wire, Spaded conductor, Liquid tight conduit connector (not supplied)
- Prepare for Wiring
Turn power OFF. Select cable size according to the ampere rating of the device. Establish a wiring pattern ensuring the same colored wire is used for the same terminal on all devices. Note that DuraGard devices are polarized and will only accept plugs one way.
- Disassemble the Device
Disassemble the device by removing the gland nut (#8), seal (#6), conduit adapter (#7), liner (#5), and interior (#2). For connectors, separate the interior from the housing by inserting a small screwdriver or drive pin into the current sleeve from the front and tapping lightly.
- Prepare and Attach Conduit Adapter
Place the conduit adapter (#7) into the gland nut (#8) and thread it onto the liquid tight conduit connector (#9, not supplied). Torque the conduit adapter tightly (50 IN/LB MIN) to the conduit connector using channel lock pliers.
- Prepare and Insert Wires
Slide the seal (#6) and liner (#5) over the supply wires (#10) and the spaded conductor (#10A). Allow 1-1/4 to 1-1/2 inches of wire to extend beyond the edge of the liner. Strip the wire 1/2 inch for 30 & 50 AMP devices or 3/4 inch for 60 AMP devices. Loosen pressure screws (#2A) and insert the stripped end of each conductor, including the spaded conductor (#10A) with the ground wire (#10) nested on top, into the contacts (#2B) according to your established wiring pattern.
- Tighten Wire Connections
Tighten the pressure screws (#2A) to 20 IN/LB for 30 & 50 AMP devices or 25 IN/LB for 60 AMP devices.
- Reassemble the Device
Reassemble the interior (#2) into the housing (#1) by aligning the tabs on the housing with the notches on the interior. Ensure the top edge of the liner (#5) is flush with the top edge of the housing (#1). Thread the gland nut (#8) onto the housing (#1), ensuring only the gland nut turns to prevent wire twisting. Tighten the gland nut (#8) to 40-80 IN/LB and the thread locking screw (#8A) to 2 IN/LB.
- Perform Electrical Tests
WARNING: Do not connect to power until electrical tests are performed. Use an ohmmeter to check continuity of wiring for correct phasing and grounding connections. Check insulation resistance to ensure there are no short circuits or unwanted grounds.
- Final Connection and Testing
Connect all devices in the system. Turn the power on and test the entire system.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.