ABB Installation Products 750J3-U 600 Amp Elbow Connector, 3-Way Junction, DeadBreak, 35KV, Rubber Junction with Stainless…
UPC: 783786395477
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 600 Amp rating for high-current medium-voltage applications
- 3-Way junction for branching three conductors in underground/pad-mounted switchgear
- DeadBreak design enables safe connection/disconnection under load
- Molded rubber junction body with stainless steel mounting hardware
- Supports 700 MCM copper conductors (ABB catalog 54880BE)
- Supports copper conductors up to 700 MCM wire size
- Stainless steel mounting plate, back plate, and hardware for corrosion resistance
Specifications
Application | 35 kV, 600 Amps |
Connection Type | Deadbreak |
Current Rating | 600 A |
Material | Rubber with stainless steel |
Mounting Type | Stainless steel mounting plate, back plate and adjustable mounting bracket |
Poles | 3-Way |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Junction 3-Way |
Voltage Rating | 35kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

J4-2266-35-N
4 Point Junction, with two 200 Amp Bushing Well Interfaces and two 600 Amp Bushing interfaces, 35kV, No Parking Stand.
167-31-1
White Identification Band with Black Stripe, for 3-Phase Loadbreak Elbow. Length 9 inch, Width 1/2 inch, Thickness .025 inch.
755LINK-BLRM0300ADRG
600 Amp, 35KV, Cam-Op Kit, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
1601-348
Gasket, Inside Diameter Diameter 2-59/64 inch, Outside Diameter 3-27/64 inch. Thickness of Gasket 3/16 inch. Oil Resistant Rubber Material.
756LINKC-DP0578805
600 Amp, 35KV, Cam-Op Connector Kit, with capacitive test point, (LR-L0300-BRK-DRG-ISO). L0300 - Cable Insulation Diameter 1.180 inch to 1.465 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 350 or Compacted/Solid 400. DRG - Insulating Cap. ISO - International Standard Organization.
35MTG-JAB750-4-3
Modular Cable Terminator, (class 1) includes contact rod, ground strap and rain cap. Cable Insulation Diameter 1.285 inch to 1.395 inch. Conductor Size KCMIL Stranded 700 /Solid 800. 4 Modules recommended, 15kv, Connector Style - 2- Hole Spade
755LINK-BLRP0380ADRG
600 Amp, 35KV, Cam-Op Kit, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
35MTGA-HJ300-1
3/4 inch Threaded Rod for MTG, includes Contact rod, ground strap and rain cap. Cable Insulation Diameter 1.160 inch to 1.305 inch. Conductor Size KCMIL Stranded 300 /Solid 350.Frequently Asked Questions
What is included in the 750J3 kit?
Each kit contains one basic molded junction 750J3, mounting hardware 600J3-6, two tubes of lubricant 82-08, installation instructions IS-0207, and three protective caps 750PPC-01.
What other Elastimold products are compatible with the junction?
The junction is designed to mate with ELASTIMOLD® products including the 755 Elbow Connector, 755BE Bushing Extender, and 750BEA2 Bushing Adapter.
Is the junction suitable for submersible use?
Yes, the 750J3 junction features a fully shielded, fully submersible molded rubber housing.
What standard does the 750J3 junction meet?
The 750J3 junction meets ANSI/IEEE Standard 386, Latest Revision.
What are the typical applications for this junction?
ELASTIMOLD® junctions are designed for subsurface, vault, or padmount applications. They can be used for sectionalizing, looping, tapping, and equipment bypass.
What is the product's voltage and current rating?
The 750J3 is a 35kV, 600 Amp Deadbreak 3-Way Junction. It has an operating voltage of 21.1kV Phase-to-Ground and a continuous current rating of 600 Amps.
What standard does the 750J3 junction meet?
The 750J3 junction meets ANSI/IEEE Standard 386, Latest Revision.
What is the product's voltage and current rating?
The 750J3 is a 35kV, 600 Amp Deadbreak 3-Way Junction. It has an operating voltage of 21.1kV Phase-to-Ground and a continuous current rating of 600 Amps.
What are the typical applications for this junction?
ELASTIMOLD® junctions are designed for subsurface, vault, or padmount applications. They can be used for sectionalizing, looping, tapping, and equipment bypass.
Is the junction suitable for submersible use?
Yes, the 750J3 junction features a fully shielded, fully submersible molded rubber housing.
How to Install the LINK-C Deadbreak Cam Link Operable Connector System
This guide provides step-by-step instructions for the safe and proper installation of the LINK-C 600 amp deadbreak cam link operable connector system. Ensure all apparatus are de-energized before beginning installation to prevent serious injury or death.
Estimated time: 1h 30m
Tools needed:
Hot stick, Torque wrench, Suitable tool for 1 inch hex portion (e.g., socket wrench), 600ATM Operating Tool, Wire strippers, Welding equipment (if using welded studs)
Supplies needed:
ELASTIMOLD supplied lubricant, 3/8-16 x 2 inch welded studs (3), 3/8-16 hex nuts (6), Lockwashers (3), No. 14 AWG or No. 12 AWG solid copper wire, Appropriate grounding connector, Spacers (optional, not supplied)
- De-energize and Inspect Apparatus
DANGER: Ensure all apparatus are completely de-energized before starting any installation or removal procedures. Verify that all components are undamaged, rated correctly, and compatible with mating parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.
- Install the 600 Amp Elbow
Install the 600 amp elbow onto the cable according to its specific installation instructions. Ensure the elbow is positioned to align correctly with the stand-off plug.
- Determine Mounting Type and Install Stand-Off Plug (if applicable)
Identify whether your installation requires a Mounted Stand-Off Plug. If so, weld three 3/8-16 x 2 inch studs to the faceplate according to the specified dimensions. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Install the stand-off plug over the studs, resting on the nuts or optional spacers. Secure with lockwashers and hex nuts, tightening to 12 foot-lbs torque. Verify that the top surfaces of the bushing and stand-off plug are in-line.
- Install Bushing Extender and Elbow onto Apparatus
Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD supplied lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM into the retainer contact, engage the internal hex broach, and thread into the apparatus bushing using a suitable tool on the 1 inch hex portion of the 600ATM, torquing to 50-60 ft-lbs. Similarly, clean and lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow. Install the elbow onto the epoxy standoff plug, inserting the 600AMT into the retainer contact and threading into the plug, torquing to 50-60 ft-lbs.
- Install the Alignment Bracket
Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket using the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight.
- Position and Secure the Elbow in the Alignment Bracket
Position the elbow within the alignment bracket so that the elbow cuff is evenly aligned with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight. Ensure the elbow clamp notch faces the cable entrance of the elbow.
- Install the LINK-C Connector
Clean and lubricate both 600 ampere interfaces of the LINK-C with ELASTIMOLD supplied lubricant. Align the LINK-C so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the LINK-C, ensuring both lever arms are inside the alignment bracket legs. Engage the pivot pin into the slots of the alignment bracket legs. While pushing inward, use a hot stick on the hot stick eye to move the lever arms downward, engaging the roller pin and moving the LINK-C inward. Continue until the lever arms are perpendicular to the alignment bracket leg.
- Ground the Elbow and Cable, Install Mating Products
Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through its grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the LINK-C. Ground and then install the desired mating product onto the 200 amp interface according to its specific installation instructions. Ground the cable by twisting concentric neutral wires together or connecting a ground lead from a 20MA/21MA device to ground using an appropriate connector. For three-phase installations, tie all grounds from all three phases to a common ground point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.