ABB Installation Products 35PCJ1M1300-S 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 075114095013
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Insulation diameter range: 1.370" to 1.630"
- Conductor size: 350 AWG stranded aluminum
- Fully shielded, fully submersible molded rubber housing
- Rated for pulls up to 500 lbs; suitable for buried or vault installations
- Cold-Shrinkable Jacket Seal Included for Environmental Protection
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 350 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

35PCJ1M1300
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
69TCJS1PB33PNLNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper/no connector required, Connector Code 33P - Conductor Diameter Range - .781-.815 inch (19.84-20.70mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wires, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69TCJS1P240PNLFNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wires, Metallic Screen Continuity Kit - F - 1/0 Bonding Cable 6 foot quantity 2 with Split BOlts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69TCJN1Q241PNNBNB
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 41P - Conductor Diameter Range - 1.101-1.145 inch (27.96-29.08mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - N - Unknown, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69TCJN44B56P5UBMNB
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 56P - Conductor Diameter Range - 1.842-1.941 inch (46.79-49.30mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - U - 1.953 inch Diameter. Type Shield - B - Copper Neutral Wire, Metallic Screen Continuity Kit - M - 4 Split Bolts, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink, standard package
69TCJN44251P5PETNA
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper, Connector Code 51P - Conductor Diameter Range - 1.542-1.562 inch (39.71-39.67mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - P - 1.562 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - T - 4/0 Flat Braid 6 foot quantity 1, Armor Kit - N - not required, Outer Jacket Restoration Kit - A - Jacket Tape 10 Rolls
69TCJN4-3-4Q
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 3, 4Q
25PCJ1M2380
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 750.Frequently Asked Questions
What is the voltage rating of this ABB power cable joint?
The ABB 35kV Power Cable Joint has a voltage rating of 35 kV, suitable for medium-voltage applications.
What conductor sizes does this joint support?
This joint is designed for 350 AWG stranded aluminum conductors.
What is the compatible cable insulation diameter range?
The joint is compatible with cable insulation diameters ranging from 1.370 inches to 1.630 inches.
What type of sealing is included with this joint?
A cold-shrinkable jacket seal is included with this power cable joint for environmental protection.
What is the housing style of this power cable joint?
This power cable joint features a single-piece housing design.
How to Install the 35PCJ1 Series Wire Shielded Cable Joint
This guide provides step-by-step instructions for the permanent installation of the 35PCJ1 series straight joint, designed for wire shielded cables with aluminum or copper conductors. Ensure all safety precautions are followed for high voltage electrical equipment.
Estimated time: 2h
Tools needed:
Wire strippers, Cutting tool, Measuring tape or ruler, Wire-brush, Crimping tool, T&B WT3D tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV only), #14 AWG copper wire or equivalent (if shield wires are smaller), Cleaning supplies
- Prepare Work Area and Cables
DANGER: De-energize all apparatus in the work area before proceeding. Inspect all product components for damage, correct rating, and compatibility with mating parts. Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires on both cables. Cut both cables at the joint centerline.
- Prepare Cable 1 and Store Joint Housing
Taper the edge of Cable 1's insulation shield from 1/2 inch (13mm) to 1-1/2 inches (38mm). Clean and lubricate the tapered insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it past the shield wires for temporary storage.
- Prepare Cables for Splice and Install Splice
Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2, referring to the 'X' and 'Y' dimensions in the document. CAUTION: Do not cut or nick the cable insulation or conductor. If conductors are aluminum, wire-brush them immediately before insertion into the splice. Insert conductors into the splice and check the dimension against the 'Max Check Before' table. If it exceeds, redo assembly. Crimp the splice following its specific recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' table. If it exceeds, redo assembly. Remove any sharp protrusions or burrs generated during crimping from the splice and joint assembly area. Clean the cables where indicated and lubricate in the direction of the arrows to create a lubricant ramp at the edge of the insulation shield.
- Complete Joint Assembly and Grounding
Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch (6mm) from the edge of the splice and then 1/4 inch (6mm) from the first, with offset locking heads. Use the T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (if applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.