ABB Installation Products 167-55-3 Washer For Feed Through, 15kv, Flange, 1 inch Diameter. Stainless Steel. .165 (8 Gage).…
UPC: 075114213387
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV-rated stainless steel washer for high-voltage feed-through applications
- 1-inch diameter with flange design for secure mounting
- .025-inch thickness (8 gage) for reliable barrier performance
- Precisely machined .406-inch center hole for proper alignment
- Standard carton quantity of 15 units for efficient inventory management
Specifications
Application | 15 |
Connection Type | Feed Through |
Material | Stainless Steel |
Mounting Type | Flange |
Series | 167-55-3 |
Size | 1 inch Diameter, .165 (8 Gage) thickness, .406 inch Center Hole Diameter |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | WASHER |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

150-TB-2
15/25kV, T-Splice 6-3/4 inch Long Bail Assembly, Made of Stainless Steel, Used for Assisting Cable to Transformer Connections. Non-Current Carrying. The 150TB2 bailing assembly kit consists of a modified hold down bail for securing Elastimold® tee splice K150T to a K150DP Deadbreak insulating plug. This assembly provides positive hold down force between the tee splice and the insulating plug.
1601-492
25-35kV, Bushing Clamp Only, Carbon Steel with Zinc Chromate Plating. Three Sided with Slots in each Corner. 0.4 inch Flange.
1601-352TN
15-25-35 kV, Stud, with Hex. Chromium Copper, Matte Finish Electro-Tin Plate. Length 1-5/16 inch, Thread 3/8-16 UNC-2A. Threaded Length 1-1/16 inch.
1601-492-2
25-35kV, Bushing Clamp Only, 304 Stainless Steel - no Plating. Three Sided with Slots in each Corner. 0.4 inch Flange.
138-366-5-9
TCJ (Transmission Cable Joint) Heat Sink Housing, Outside Diameter 2.75 inch, Bore Diameter 1.25 inch.Frequently Asked Questions
What is the voltage rating of this ABB washer?
This ABB washer is rated for 15kV, making it suitable for high-voltage applications.
What material is the ABB 167-55-3 washer made from?
The ABB 167-55-3 washer is constructed from stainless steel for enhanced durability and corrosion resistance.
What are the dimensions of the center hole on this washer?
The center hole on the ABB 167-55-3 washer has a diameter of .406 inches.
What is the thickness of the ABB 167-55-3 washer?
The ABB 167-55-3 washer has a thickness of .025 inches, equivalent to 8 Gage.
What is the diameter of the ABB 167-55-3 feed-through washer?
The ABB 167-55-3 feed-through washer has a diameter of 1 inch.
How to Install the 160DRG/167DRG Insulated Cap with Ground Lead
This guide provides instructions for safely installing the 160DRG and 167DRG insulated caps, designed for insulating, shielding, and watersealing 15kV class loadbreak bushing interfaces. Ensure all apparatus is de-energized before beginning.
Estimated time: 30m
Tools needed:
Eight-foot long, fully insulated hotstick
Supplies needed:
160DRG or 167DRG Insulated Cap with Ground Lead, Lubricant (supplied or ELASTIMOLD approved), System ground connection
- De-energize Apparatus and Inspect Components
Ensure all apparatus is de-energized before beginning installation. Inspect the insulated cap, ground lead, and mating parts for any damage, proper rating, and compatibility. Verify all required tools and supplies are at hand. DANGER: All apparatus must be de-energized during installation or removal of parts, except for test point caps and indicators. Failure to follow these instructions will result in serious or fatal injury.
- Connect the Electrostatic Grounding Wire
Connect the free end of the electrostatic grounding wire to the system ground, leaving enough slack for hot-stick operation of the insulated cap. CAUTION: Train the electrostatic grounding wire so it does not contact the bushing interface during operation. WARNING: If the ground lead disconnects during operation, do not attempt to reattach without first pulling the insulated cap off the bushing with the hotstick.
- Prepare the Insulated Cap
Remove the protective cover from the insulated cap. Lubricate the cap’s internal mating surface using only the supplied lubricant or an ELASTIMOLD approved lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product and its mating products. Keep the internal mating surface free from dirt and grime. Always replace the protective cover when the cap is not in use.
- Install the Insulated Cap onto the Bushing
Firmly attach an eight-foot long, fully insulated hotstick to the insulated cap's pulling eye. Insert the male contact of the insulated cap into the loadbreak bushing, and push home with a fast, firm, straight motion. Make certain it is fully mated, with the locking ring seated. Detach the hotstick from the insulated cap.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.