ABB Installation Products 151-SPC-10AX 200 Amp, 15/25kV, Straight Replacement Contact, Wire Size 1/0.
UPC: 783786662616
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp current rating for heavy-duty industrial applications
- 15/25 kV voltage rating for medium-voltage systems
- Supports 1/0 AWG wire size for standard industrial conductors
- Straight replacement contact for direct-fit installation
- Part of ABB Installation Products series for medium-voltage applications
Specifications
Application | 15/25 kV, 200 Amps |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Straight Replacement Contact |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.1100 L |
Package Weight (Metric) | 0.0500 kg |

150-TB-2
15/25kV, T-Splice 6-3/4 inch Long Bail Assembly, Made of Stainless Steel, Used for Assisting Cable to Transformer Connections. Non-Current Carrying. The 150TB2 bailing assembly kit consists of a modified hold down bail for securing Elastimold® tee splice K150T to a K150DP Deadbreak insulating plug. This assembly provides positive hold down force between the tee splice and the insulating plug.
1601-482
Hold Down Plate Pack for Deadbreak-Loadbreak Adaptor, Stainless Steel. 4.5 inch Outside Diameter, Inside Diameter 2.835 inch, 14 Gage Thick. Four .188 inch Diameter Thru Holes evenly spaced around rim. Includes Hardware: Four Hook Bolts and Wing Nuts, Lubricant and Instructions
00701270
Aluminum Rod Contact for Aluminum only Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 4/0 - Stranded/Compressed, 250 Compact/Solid
00701250
Aluminum Rod Contact for Aluminum only Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 2/0 - Stranded/Compressed, 3/0 Compact/Solid
J6-666666-15-N-TMA
25kV, Multi-Port Junction, 6 Points, Six 600 Amp Bushing Interface, Standard Spacing - 4 inch Centers, No Parking Stand, Tilt Mounting Adapter.
00701240
Aluminum Rod Contact for Aluminum only Conductors for use with PCT (Power Cable Terminations), 15/25kv, for Conductor size 1/0 - Stranded/Compressed, 2/0 Compact/SolidHow to Install the K151SP Straight Plug for 15kV and 25kV Systems
This guide provides step-by-step instructions for installing the K151SP Straight Plug, designed to connect solid dielectric type cables to other ELASTIMOLD products on 15kV and 25kV class systems. Ensure all apparatus are de-energized before beginning installation.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Wire brush, Rag, Approved solvent, Measuring tape, Cable cutting tool
Supplies needed:
K151SP Straight Plug, Conductor Contact (female), Nylon Venting Rod, Lubricant (supplied), Crimp Chart, Solid dielectric type cable, Mating ELASTIMOLD receptacle, Copper wire (#14 AWG or equivalent), ELASTIMOLD bail, Silicone grease
- De-energize Apparatus and Inspect Components
DANGER: Ensure all apparatus are de-energized before installation or removal. Install and operate according to user, local, and national work rules. Inspect all K151SP package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Do not touch or move energized products.
- Prepare Cable Jacket
For Jacketed Concentric Neutral cable, cut and remove the cable jacket 8 inches from the cable end, allowing sufficient neutral wires for grounding. For Copper Tape Shield cable, cut and remove the cable jacket 7-1/2 inches from the cable end, then remove the copper tape shield 6-1/2 inches from the cable end. Refer to ECS or MA grounding device instructions for specific cut-back requirements if applicable.
- Remove Insulation and Conductive Shield
Remove 7/8 to 1 inch of cable insulation and conductive shield, cutting squarely without penciling. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1-3/4 to 1-7/8 inches. Wire brush bare aluminum conductors immediately and insert into the crimp barrel containing inhibitor.
- Crimp Socket Terminal
Crimp the socket terminal onto the bared conductor, holding the crimp barrel against the cable insulation. Refer to the crimp chart provided with the contact. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. Carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare and Clean Insulation
Temporarily remove the plastic pin. Remove the semi-conductive shield 7-3/4 to 7-13/16 inches back from the end of the socket with a straight, smooth, squared cut, ensuring not to cut or nick the insulation. Replace the plastic pin. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with an approved solvent, wiping from the cable end toward the outer jacket. Install ECS or MA grounding device if applicable.
- Lubricate Cable and Housing
Slide the collar, smaller end first, onto the cable. Keep the cable insulation and plug clean. Apply the supplied lubricant sparingly to the cable as shown in the instructions and to the inside of the housing. DO NOT SUBSTITUTE lubricants, as others may be harmful to the product.
- Install Plug on Cable
Push the cable into the housing until the leading edge of the socket contact is flush with the front edge of the plug. Remove the plastic pin from the socket and discard it.
- Connect to Mating Receptacle
Lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approx. 1-3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection using an ELASTIMOLD bail, referencing the Bailing Instruction Sheet (150TB-4).
- Connect Grounding
If an ELASTIMOLD grounding device is not used, connect a length of #14 AWG (or equivalent) copper wire through the grounding tab and twist tightly. Connect this grounding assembly to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.