ABB Installation Products 00400250 15/25kV, 200 Amp, RLR Contact, Replacement Elbow Connector for Aluminum and Copper…
UPC: 783786357727
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 15/25kV, 200 Amp medium-voltage applications
- Supports conductor sizes 2/0-3/0 (stranded/compressed or solid/compact)
- 11.805-inch length for installation in tight spaces
- RLR contact design ensures consistent electrical and mechanical performance
- Compatible with standard 15kV and 25kV loadbreak elbows
Specifications
Amperage Rating | 200 A |
Application | Designed for use with 167/168RLR and 273/274RLR Replacement Elbows on Aluminum or Copper Conductors |
Connection | Compression |
Connection Type | RLR Contact |
Current Rating | 200 A |
Finish | Tin Plated |
Housing Material | Bi-Metal |
Insulation | None |
Material | Aluminum and Copper Conductors compatible |
Series | 400250 |
Size | 11.805 inches long |
Size | 2/0-250 Stranded/Compressed, 3/0 Compact/Solid |
Special Features | Bi-Metallic Connector. Comes with Crimp Chart |
Type | Contact |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Wire Size | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.7000 L |
Package Weight (Metric) | 0.3180 kg |

02500250
15-35kV 200 Amp, Loadbreak LR Long Bi-Metal Contact - Size Code 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. 2.88 inch long
N-1/0SP
All Purpose Split Bolt Connector 1/0 AWG All Purpose Split Bolt Connectors are used for combinations of aluminum to copper, aluminum to aluminum, steel to aluminum, copper to copper, and steel to copper applications. They have an electro-tinned body. UL listed for copper and copperweld wires only. Includes nut, spacer and pressure pad.
GLE 3/0 N
Aluminum Two-Hole Non-Tension Compression Lug - Wire Size 3/0 Stranded-Compressed-Compact. Length 59/32 inch. Pad 1-1/8 inch wide x 3-1/8 inch long x 9/32 inch thick. (2) Holes 9/16 inch Diameter on 1-3/4 inch Center. Barrel 1-15/32 inch long. Oxide Inhibitor with Black Cap. Dies CSA24, 702, 298. Dual Rated for Aluminum and Copper Conductors
AL 400 N 24 HS
Aluminum Two-Hole NEMA Lugs - straight lug, 397.5 - 400 kcmil AL-CU, ACSR 336.4 (26/7) and 397.5 (18/1), installing dies 96, 472, 655, 1 1/8-1, 1 1/8-2, 705, 316, 13A. Length 24 inch. Pad 1-5/8 inch wide x 3-9/16 inch long x 13/32 inch thick. (2) 9/16 inch diameter holes on 1-3/4 inch centers. Barrel 19-9/16 inch long x 1-3/16 inch Outside Diameter. Oxide Inhibitor. Green Cap. Includes Heat Shrink.
0520233P
Heat Transfer Copper Connector - PCJ Style 1. Length 4.281 inch. Widest Diameter 1.375 inch. 500 kcmil Stranded Copper. Electro Tin Plated
AL 400 N 16 HS
Aluminum Two-Hole NEMA Lugs - straight lug, 397.5 - 400 kcmil AL-CU, ACSR 336.4 (26/7) and 397.5 (18/1), installing dies 96, 472, 655, 1 1/8-1, 1 1/8-2, 705, 316, 13A. Length 16 inch. Pad 1-5/8 inch wide x 3-9/16 inch long x 13/32 inch thick. (2) 9/16 inch diameter holes on 1-3/4 inch centers. Barrel 11-9/16 inch long x 1-3/16 inch Outside Diameter. Oxide Inhibitor. Green Cap. Includes Heat Shrink.
AL 1590-4 N
Aluminum Four Hole NEMA Lug, 1590 kcmil AA, 1272 (45/7) ACSR, Installing Dies 728, 38AH, 189. Length 13-1/2 inch. Pad 3 inch wide x 3-5/8 inch long x 3/4 inch thick. (4) 9/16 inch Diameter Holes on 1-3/4 inch Centers. Barrel 8-7/16 inch long x 2-1/4 inch Outside Diameter. Oxide Inhibitor. Yellow Cap. Dual Rated for Aluminum and Copper ConductorsFrequently Asked Questions
Can these connectors be used with aluminum or copper conductors?
Yes, these connectors are designed for use on both aluminum or copper conductors.
With which replacement elbows are these connectors compatible?
These units are designed for use with 167/168RLR and 273/274RLR replacement elbows.
What components are included in the 00400XXX kit?
Each kit contains one 00400XXX connector and one Crimp Chart CC-0060.
What materials are the 00400XXX connectors made of?
The 00400XXX bi-metallic connectors feature a copper tip section and an aluminum crimp barrel.
What conductor sizes are compatible with 00400250?
The 00400250 connector is compatible with 2/0 AWG stranded/compressed and 3/0 AWG solid/compressed bi-metal conductors.
What is the product type and rating?
The product is a 15/25kV 200A Loadbreak RLR Contact.
What is the product type and rating?
The product is a 15/25kV 200A Loadbreak RLR Contact.
Can these connectors be used with aluminum or copper conductors?
Yes, these connectors are designed for use on both aluminum or copper conductors.
With which replacement elbows are these connectors compatible?
These units are designed for use with 167/168RLR and 273/274RLR replacement elbows.
What components are included in the 00400XXX kit?
Each kit contains one 00400XXX connector and one Crimp Chart CC-0060.
How to Install and Connect the 273RLR/274RLR Loadbreak Replacement Elbow Connector
A comprehensive guide for installing, wiring, and connecting the 273RLR or 274RLR Loadbreak Replacement Elbow Connector to convert a livefront termination to deadfront for UD cable.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Wire brush, Crimping tool, Probe Wrench, Hotstick (full insulated live-line tool), Suitable sensing device (for 274RLR voltage test)
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate ground connector, Silicone grease
- De-energize Apparatus and Remove Livefront Termination
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Remove the terminator housing from the cable.
- Prepare the Cable
Train cables to be straight and in-line with the bushing centerline. Cut the cable to measure 10-1/2 inches from the bushing centerline. Remove 1-3/8 inches of cable insulation from the end of the cable, cutting squarely. DO NOT NICK THE CONDUCTOR.
- Install Compression Lug
Wire brush the bare aluminum conductor immediately. Install the compression lug, rotating it to spread the inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep insulation clean of dirt and grime. Do not use excess grease and do not introduce any grease into the gap between the lug and the insulation. Slide the elbow connector onto the cable with a back and forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread; it must turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Connect Concentric Neutral
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. Add the supplied hose clamp and tighten it snugly, but do not overtighten.
- Connect Elbow to Bushing (Loadmake Operation)
DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY if the transformer and elbow are known to be de-energized. DO NOT OPERATE BY HAND. Remove the insulated cap from the bushing by attaching a hotstick tool to its pulling eye. Securely fasten a hotstick to the loadbreak connector pulling eye. After establishing firm footing and positive control, withdraw the elbow from the apparatus parking stand with a fast, straight, firm motion, being careful not to place the elbow connector near a ground plane. Place the elbow connector receptacle over the bushing plug, inserting the elbow male contact (arc follower portion) into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface, applying sufficient force.
- Perform Voltage Test (274RLR only)
If installing a 274RLR (with Test Point), remove the test point cap with a hotstick by peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device made for use with separable connectors manufactured with capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or use of the wrong measuring equipment can provide a false “no voltage” indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.