ABB Signature Partner Distributor (Electrification)
ABB - Electrification TQL100S - GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included 100S Amps 100 A
More images

ABB Electrification TQL100S GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as…

UPC: 783164021424


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB TQL100S (SKU: TQL100S) is a NEMA Type 3R outdoor, raintight circuit breaker enclosure from ABB - Electrification, designed for reliable power distribution and protection. This enclosure is UL Listed and CSA Certified, making it suitable for use as service equipment (SE) in industrial and commercial applications, meeting NEC 2020 and 2023 requirements for emergency outdoor disconnects. It is engineered to house THQL, TXQL, and THQL-GF circuit breakers, supporting 1, 2, or 3-pole configurations with a maximum ampere rating of 100A. The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Key specifications include: * **Frame Types Supported:** THQL, TXQL, THQL-GF * **Pole Configurations:** 1, 2, or 3-pole (Note: 3-pole breaker with accessory is not accommodated) * **Max. Ampere Rating:** 100 A * **Conductor Ratings:** 60°C/75°C * **Conductor Size:** #4 to 1/0 AWG for copper or aluminum conductors. This enclosure features corrosion-resistant steel construction with a durable powder-coated finish for longevity in harsh environments. It includes knockouts for conduit entry and supports surface or flush mounting. A neutral kit for non-ground fault applications is included, simplifying installation. The TQL100S is an ideal choice for outdoor installations, service entrance barriers, and emergency disconnects, providing dependable protection. Distributed by Gross Automation.
  • NEMA Type 3R outdoor, raintight enclosure for circuit breakers
  • UL Listed and CSA Certified, suitable for service equipment (SE)
  • Accommodates THQL, TXQL, THQL-GF circuit breakers (1, 2, 3-pole)
  • 100 Ampere maximum rating with equal short circuit rating to installed breaker
  • Corrosion-resistant steel construction with powder-coated finish

Specifications

Connection Type
Copper or Aluminum Conductors (#4 to 1/0 AWG)
Current Rating
100 A
Enclosure
NEMA TYPE 1
Frame
Q-Line
Material
Steel
Mounting Type
Surface
Mounting Type
Surface or Flush
NEMA Rating
Type 3R
Poles
1, 2, or 3 pole
Series
TQL
Special Features
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included 100S Amps 100 A
Standard
CSA / UL
Package Dimensions (L x W x H)
18 IN x 8.25 IN x 5.5 IN
Package Dimensions (L x W x H)
45.72 cm x 20.955 cm x 13.97 cm
Package Weight (Imperial)
8.126 L
Package Weight (Metric)
3.686 kg
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:THQC, THHQC, TXQC (1, 2, 3 Pole) ¶Enclosure notes and/or limitation: Enclosure cannot accommodate a 3-pole breaker with accessory.¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included

TQC100F

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:THQC, THHQC, TXQC (1, 2, 3 Pole) ¶Enclosure notes and/or limitation: Enclosure cannot accommodate a 3-pole breaker with accessory.¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions: Enclosure can also be used with TJD. Enclosure notes and/or limitation: Suitable for parallel 250 kcmil cable maximum (use 600 amp enclosure if larger cable is required). Enclosure does not include knockouts (NEMA Type 12). ACCESSORIES: Neutral Kit (non-GF applications): TNIA400

TJ400J

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions: Enclosure can also be used with TJD. Enclosure notes and/or limitation: Suitable for parallel 250 kcmil cable maximum (use 600 amp enclosure if larger cable is required). Enclosure does not include knockouts (NEMA Type 12). ACCESSORIES: Neutral Kit (non-GF applications): TNIA400
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:TQD, THQD (2, 3 Pole)¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included

TQD225F

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:TQD, THQD (2, 3 Pole)¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. Enclosure includes removable closing cap. ACCESSORIES Neutral Kit (non-GF applications) included Raintight Hubs TC 75, TC 10 0, TC125, TC150, T CCP 100F Amps 100 A

TQL100F

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. Enclosure includes removable closing cap. ACCESSORIES Neutral Kit (non-GF applications) included Raintight Hubs TC 75, TC 10 0, TC125, TC150, T CCP 100F Amps 100 A
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. Enclosure includes removable closing cap. ACCESSORIES Neutral Kit (non-GF applications) included Raintight Hubs TC 75, TC 10 0, TC125, TC150, T CCP L70F Amps 70 A

TQL70F

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. Enclosure includes removable closing cap. ACCESSORIES Neutral Kit (non-GF applications) included Raintight Hubs TC 75, TC 10 0, TC125, TC150, T CCP L70F Amps 70 A
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included L70R Amps 70 A

TQL70R

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included L70R Amps 70 A
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions TQD, THQD (2, 3 Pole) ACCESSORIES Neutral Kit (non-GF applications) included 100S Amps 100 A

TQC100S

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions TQD, THQD (2, 3 Pole) ACCESSORIES Neutral Kit (non-GF applications) included 100S Amps 100 A
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:THQC, THHQC, TXQC (1, 2, 3 Pole) ¶Enclosure notes and/or limitation: Enclosure cannot accommodate a 3-pole breaker with accessory. ¶Enclosure includes removable closing cap.¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included ¶Raintight Hubs: TC75, TC100, TC125, TC150, TCCP

TQC100R

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:THQC, THHQC, TXQC (1, 2, 3 Pole) ¶Enclosure notes and/or limitation: Enclosure cannot accommodate a 3-pole breaker with accessory. ¶Enclosure includes removable closing cap.¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included ¶Raintight Hubs: TC75, TC100, TC125, TC150, TCCP

Frequently Asked Questions

What material is the TQL100S enclosure made from?

The TQL100S enclosure is made from steel.

What is the weight of the TQL100S enclosure?

The TQL100S enclosure weighs 35 lbs.

What is the amperage rating of the TQL100S enclosure?

The TQL100S enclosure has an amperage rating of 100A.

Does the TQL100S enclosure comply with UL and CSA standards?

Yes, the TQL100S enclosure is UL and CSA listed and certified.

What are the dimensions of the TQL100S enclosure?

The TQL100S enclosure has a height of 24 inches, a width of 14 inches, and a depth of 6 inches.

What type of circuit breaker enclosures are these?

These are NEMA Type 1 circuit breaker enclosures suitable for use as service equipment.

What type of mounting is required for this enclosure?

The TQL100S enclosure is designed for surface mounting.

What is the short circuit rating of the enclosure?

The short circuit rating of the enclosure circuit breaker combination is equal to the short circuit rating of the installed circuit breaker.

Can this enclosure accommodate a 4-pole breaker with accessories?

No, the enclosure cannot accommodate a 4-pole breaker with accessories for non-FG applications.

Frequently Asked Questions about ABB - Electrification

What industries and applications are Jokab Safety products used for?

Jokab Safety products are specifically designed for machine safety applications across multiple critical industrial sectors, including Food and Beverage, Packaging, and Material Handling industries. Their safety solutions cover a wide range of machine safeguarding needs, such as safety light guards, safety controllers, safety relays, safety edges, safety mats, and two-hand control devices that protect personnel and equipment in complex industrial automation environments.

What technical support does Jokab Safety offer?

Jokab Safety offers comprehensive technical support through multiple channels, including a dedicated technical support phone line at (888) 385-1221 (Option 1) and email support at [email protected]. For advanced technical assistance, customers can contact their specialized Jokab Tech Support at (519) 982-0976 or email [email protected]. Additionally, they provide product specialist support through Jeff Leslie, who can be reached at (519) 982-0976, offering in-depth application and technical guidance.

What are the main product lines offered by Jokab Safety?

Jokab Safety offers a comprehensive range of machine safety products including safety light guards (Orion), safety controllers (Pluto), safety relays (Sentry), safety edges, safety contact mats, safety locks (Gkey), and safety sensors with OSSD and DYNlink interfaces. Their product lines are specifically designed for industrial applications in food and beverage, packaging, and material handling industries, providing robust safety solutions for machine guarding and personnel protection.

What are the key features of Jokab Safety products?

Jokab Safety products offer comprehensive industrial safety solutions with key features including: highest safety certification levels (up to PL e/Cat 4), extensive fault detection, multiple safety device types (optical safety devices, pressure sensitive devices, sensors, switches, locks, emergency stops), and innovative DYNlink technology that reduces cable requirements and simplifies installation. Their products are certified, verified, and compatible with major industrial automation systems like B&R, featuring easy M12 connector connections and a wide range of adapters to streamline safety implementation.

What certifications and standards do ABB - Electrification products comply with?

ABB - Electrification products comply with a comprehensive range of international certifications and standards, including UL (United States), CSA (Canada), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia & New Zealand). Our products meet critical international standards such as IEC 60947 series for low-voltage switchgear, functional safety standards EN 61800-5-2 and ISO 13849-1, and marine classification standards from Bureau Veritas, DNV, and Lloyd's Register of Shipping.

What industries and applications are ABB - Electrification products used for?

ABB - Electrification products are engineered for critical applications across multiple industries, including Energy, Oil & Gas, Manufacturing, Power Generation, HVAC, Marine, Food & Beverage, Mining, Pulp & Paper, Water Treatment, and Automotive. Their solutions cover essential electrical infrastructure needs such as switchgear, power distribution systems, circuit protection, digital control technologies, and drive systems designed for high-reliability environments with a strong focus on sustainability, efficiency, and safety.

What technical support does ABB - Electrification offer?

ABB - Electrification offers comprehensive technical support through multiple channels, including a dedicated technical support hotline at 888-385-1221 (Option 1), available 7:00 a.m. - 5:00 p.m. CST, Monday-Friday. Their support services encompass 24/7/365 emergency services, on-site support, remote monitoring and diagnostics, installation and commissioning, equipment assessments, repair coordination, and multi-vendor technical assistance. Customers can also access resources like personnel safety training, disaster recovery support, and service agreements tailored to their specific electrification needs.

What are the main product lines offered by ABB - Electrification?

ABB - Electrification offers a comprehensive range of electrical distribution and protection products, including circuit monitoring systems, panelboards, switchgear, motor control centers, circuit breakers, softstarters, and power distribution solutions. Key product lines span low and medium voltage applications across utilities, commercial, industrial, healthcare, and manufacturing sectors, with specialized offerings like the ReliaGear® panelboards, SMISSLINE TP bus systems, and Ekip UP protection and metering relays.

What are the key features of ABB - Electrification products?

ABB - Electrification products feature advanced integrated design elements that enhance industrial performance and reliability. Key features include harmonics and EMC design, integrated DC choke, removable terminals for fast installation, USB ports for troubleshooting, and integrated Safe Torque Off (STO) functionality. The products deliver superior motor control capabilities, support both induction and permanent magnet motors, and offer robust operational features like side-by-side mounting without derating and operation at temperatures up to 45°C. Additionally, ABB's Electrification solutions emphasize digital innovation, with technologies like Novolink enabling predictive maintenance, enhanced analytics, and seamless system integration.

What communication protocols do ABB - Electrification products support?

ABB - Electrification products support a comprehensive range of industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, DeviceNet, and IEC 61850. These protocols enable flexible connectivity across multiple industrial automation platforms, with support for various network topologies and high-speed data transmission up to 100 Mbps.