ABB - Electrification TNIA800UR - General Electric Industrial enclosure, miscellaneous. Industrial breakers. Circuit breaker enclosure - neutral.
ABB - Electrification

TNIA800UR

UPC: 783164449259

Contact for Pricing

Overview

The ABB TNIA800UR is a NEMA Type 12 industrial circuit breaker enclosure designed for Tmax XT6 frame breakers rated up to 800A with 3 poles. This UL and cUL certified enclosure is manufactured in the USA and suitable for service equipment (SE) applications where dust and falling dirt protection are required. The enclosure features a neutral configuration with 60°C/75°C conductor ratings and short circuit ratings matching the installed breaker for reliable operational continuity. It includes knockouts for flexible installation and supports ground fault protection integration via neutral sensors (e.g., 1SDA105158R1 for 800A). Compatible with Tmax XT6 frame breakers, the TNIA800UR is ideal for critical electrical infrastructure requiring Type 12 indoor protection. The enclosure’s design aligns with ABB’s industrial standards for durability and compliance. It is constructed from high-quality steel with a durable powder-coated finish to resist corrosion and environmental damage. The enclosure meets NEMA Type 12 standards for protection against dust, falling dirt, and dripping non-corrosive liquids, ensuring long-term reliability in harsh industrial environments. The TNIA800UR supports a wide range of Tmax XT6 breakers, including thermal-magnetic and electronic trip units, providing flexibility for various application needs. It includes pre-punched knockouts for easy cable entry and exit, simplifying installation and reducing downtime. The neutral configuration allows for proper grounding and fault protection, enhancing system safety. The enclosure is designed for indoor use and meets stringent UL and cUL certification requirements, ensuring compliance with North American electrical standards.
  • NEMA Type 12 rated for indoor protection against dust, falling dirt, and non-corrosive liquid drips
  • UL and cUL certified for North American electrical standards compliance
  • 800A 3-pole configuration with neutral support for Tmax XT6 frame breakers
  • High-quality steel construction with powder-coated finish for corrosion resistance
  • Pre-punched knockouts for flexible cable entry and ground fault protection integration

Specifications

Application
Electrical distribution and Control
Current Rating
800 A
Material
Steel
Nema Rating
Type 12
Poles
3
Poles
3-pole
Series
Tmax XT
Series
Tmax XT6
Type
Circuit Breakers
Package Weight (Imperial)
0.001 L
Package Weight (Metric)
0.001 kg
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions: Enclosure can also be used with TJD. Enclosure notes and/or limitation: Suitable for parallel 250 kcmil cable maximum (use 600 amp enclosure if larger cable is required). Enclosure does not include knockouts (NEMA Type 12). ACCESSORIES: Neutral Kit (non-GF applications): TNIA400

TJ400J

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions: Enclosure can also be used with TJD. Enclosure notes and/or limitation: Suitable for parallel 250 kcmil cable maximum (use 600 amp enclosure if larger cable is required). Enclosure does not include knockouts (NEMA Type 12). ACCESSORIES: Neutral Kit (non-GF applications): TNIA400
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:3 pole only. ¶Enclosure notes and/or limitation: Enclosure does not include knockouts (NEMA Type 12).¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included

TE100J

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:3 pole only. ¶Enclosure notes and/or limitation: Enclosure does not include knockouts (NEMA Type 12).¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:3 pole only. ¶Enclosure notes and/or limitation: Enclosure includes knockouts (NEMA Type 12K).¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included

TE100D

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. ¶¶Frame notes and/or restrictions:3 pole only. ¶Enclosure notes and/or limitation: Enclosure includes knockouts (NEMA Type 12K).¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included
General Electric Industrial enclosure, miscellaneous. Industrial breakers. Neutral for circuit breaker enclosure.

TNIA400VGUR

General Electric Industrial enclosure, miscellaneous. Industrial breakers. Neutral for circuit breaker enclosure.
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. ¶¶Enclosure notes and/or limitation: For 3 phase, 4-wire ground fault, order neutral kit and neutral current sensor kit (kits must be mounted in enclosure).¶Enclosure does not include knockouts (NEMA Type 12).¶¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):TNIA400 ¶Neutral Kit(s) (for GF applications): TNIA400VG ¶Neutral Current Sensor(s) (for GF applications): TSRG201, TSRG204

SG400J

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. ¶¶Enclosure notes and/or limitation: For 3 phase, 4-wire ground fault, order neutral kit and neutral current sensor kit (kits must be mounted in enclosure).¶Enclosure does not include knockouts (NEMA Type 12).¶¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):TNIA400 ¶Neutral Kit(s) (for GF applications): TNIA400VG ¶Neutral Current Sensor(s) (for GF applications): TSRG201, TSRG204
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. ¶¶Enclosure notes and/or limitation: Enclosure includes knockouts (NEMA Type 12K). ¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included

SE100D

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. ¶¶Enclosure notes and/or limitation: Enclosure includes knockouts (NEMA Type 12K). ¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder

AB553

The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder

AB643

The NEMA 3R enclosures feature a standard padlock-able handle feature. They are galvanised steel coated with Pulvalar 115 powder
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included 100S Amps 100 A

TQL100S

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included 100S Amps 100 A
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included 100R Amps 100 A

TQL100R

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Frame notes and/or restrictions THQL, TXQL, THQL-GF (1, 2, 3 Pole) Enclosure notes and/or limitation Enclosure cannot accommodate a 3-pole breaker with accessory. ACCESSORIES Neutral Kit (non-GF applications) included 100R Amps 100 A
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. , , Frame notes and/or restrictions:2 and 3 pole only , , ACCESSORIES: , Neutral Kit (non-GF applications):included

TE100F

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. , , Frame notes and/or restrictions:2 and 3 pole only , , ACCESSORIES: , Neutral Kit (non-GF applications):included
GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. ¶¶Frame notes and/or restrictions:2 and 3 pole only. ¶Enclosure notes and/or limitation: Enclosure includes removable closing cap.¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included¶Raintight Hubs: TC150, TC200, TC250, TCCP

TE150R

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only. ¶¶Frame notes and/or restrictions:2 and 3 pole only. ¶Enclosure notes and/or limitation: Enclosure includes removable closing cap.¶¶ ACCESSORIES: ¶Neutral Kit (non-GF applications):included¶Raintight Hubs: TC150, TC200, TC250, TCCP

Frequently Asked Questions about ABB - Electrification

What industries and applications are Jokab Safety products used for?

Jokab Safety products are specifically designed for machine safety applications across multiple critical industrial sectors, including Food and Beverage, Packaging, and Material Handling industries. Their safety solutions cover a wide range of machine safeguarding needs, such as safety light guards, safety controllers, safety relays, safety edges, safety mats, and two-hand control devices that protect personnel and equipment in complex industrial automation environments.

What technical support does Jokab Safety offer?

Jokab Safety offers comprehensive technical support through multiple channels, including a dedicated technical support phone line at (888) 385-1221 (Option 1) and email support at [email protected]. For advanced technical assistance, customers can contact their specialized Jokab Tech Support at (519) 982-0976 or email [email protected]. Additionally, they provide product specialist support through Jeff Leslie, who can be reached at (519) 982-0976, offering in-depth application and technical guidance.

What are the main product lines offered by Jokab Safety?

Jokab Safety offers a comprehensive range of machine safety products including safety light guards (Orion), safety controllers (Pluto), safety relays (Sentry), safety edges, safety contact mats, safety locks (Gkey), and safety sensors with OSSD and DYNlink interfaces. Their product lines are specifically designed for industrial applications in food and beverage, packaging, and material handling industries, providing robust safety solutions for machine guarding and personnel protection.

What are the key features of Jokab Safety products?

Jokab Safety products offer comprehensive industrial safety solutions with key features including: highest safety certification levels (up to PL e/Cat 4), extensive fault detection, multiple safety device types (optical safety devices, pressure sensitive devices, sensors, switches, locks, emergency stops), and innovative DYNlink technology that reduces cable requirements and simplifies installation. Their products are certified, verified, and compatible with major industrial automation systems like B&R, featuring easy M12 connector connections and a wide range of adapters to streamline safety implementation.

What certifications and standards do ABB - Electrification products comply with?

ABB - Electrification products comply with a comprehensive range of international certifications and standards, including UL (United States), CSA (Canada), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia & New Zealand). Our products meet critical international standards such as IEC 60947 series for low-voltage switchgear, functional safety standards EN 61800-5-2 and ISO 13849-1, and marine classification standards from Bureau Veritas, DNV, and Lloyd's Register of Shipping.

What industries and applications are ABB - Electrification products used for?

ABB - Electrification products are engineered for critical applications across multiple industries, including Energy, Oil & Gas, Manufacturing, Power Generation, HVAC, Marine, Food & Beverage, Mining, Pulp & Paper, Water Treatment, and Automotive. Their solutions cover essential electrical infrastructure needs such as switchgear, power distribution systems, circuit protection, digital control technologies, and drive systems designed for high-reliability environments with a strong focus on sustainability, efficiency, and safety.

What technical support does ABB - Electrification offer?

ABB - Electrification offers comprehensive technical support through multiple channels, including a dedicated technical support hotline at 888-385-1221 (Option 1), available 7:00 a.m. - 5:00 p.m. CST, Monday-Friday. Their support services encompass 24/7/365 emergency services, on-site support, remote monitoring and diagnostics, installation and commissioning, equipment assessments, repair coordination, and multi-vendor technical assistance. Customers can also access resources like personnel safety training, disaster recovery support, and service agreements tailored to their specific electrification needs.

What are the main product lines offered by ABB - Electrification?

ABB - Electrification offers a comprehensive range of electrical distribution and protection products, including circuit monitoring systems, panelboards, switchgear, motor control centers, circuit breakers, softstarters, and power distribution solutions. Key product lines span low and medium voltage applications across utilities, commercial, industrial, healthcare, and manufacturing sectors, with specialized offerings like the ReliaGear® panelboards, SMISSLINE TP bus systems, and Ekip UP protection and metering relays.

What are the key features of ABB - Electrification products?

ABB - Electrification products feature advanced integrated design elements that enhance industrial performance and reliability. Key features include harmonics and EMC design, integrated DC choke, removable terminals for fast installation, USB ports for troubleshooting, and integrated Safe Torque Off (STO) functionality. The products deliver superior motor control capabilities, support both induction and permanent magnet motors, and offer robust operational features like side-by-side mounting without derating and operation at temperatures up to 45°C. Additionally, ABB's Electrification solutions emphasize digital innovation, with technologies like Novolink enabling predictive maintenance, enhanced analytics, and seamless system integration.

What communication protocols do ABB - Electrification products support?

ABB - Electrification products support a comprehensive range of industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, DeviceNet, and IEC 61850. These protocols enable flexible connectivity across multiple industrial automation platforms, with support for various network topologies and high-speed data transmission up to 100 Mbps.