ABB - Electrification Signature Partner Distributor
ABB - Electrification 9T76H9872G03 - ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
More images
ABB - Electrification

9T76H9872G03

UPC: 783173252284


Documents & Media
Specification Sheet

Contact for Pricing

Overview

ABB Guard III Harmonic Mitigating Transformers (HMT) (SKU: 9T76H9872G03) are three-phase, zig-zag secondary transformers engineered to actively reduce current harmonics on the primary side and voltage distortion on the secondary. Designed for environments with significant non-linear loads—such as data centers, medical facilities, office buildings, and schools—the Guard III HMT maintains DOE 2016 energy efficiency standards even under harmonic conditions, reducing energy losses from heating and improving overall system efficiency. Key features include dual electrostatic shields, a heat-cured ASA-61 gray powder coating finish, and a NEMA 2 enclosure for protection. The transformer is available in a kVA range from 15 to 1,500 kVA, with 0° and -30° phase shifts to mitigate triplen harmonics (3rd, 9th, 15th, 21st) and, when paired, reduce 5th and 7th harmonics. Constructed with high-quality electrical steel cores and copper windings, it offers robust durability and reliable performance. Standard specifications include a 480V primary, 208Y/120V zig-zag secondary voltage, 150°C temperature rise, and a 220°C insulation class. The Guard III HMT is qualified to seismic requirements of IEEE-693-2005, IBC-2021, and CBC 2022, making it ideal for critical applications where stable power is paramount. The transformer's dual electrostatic shields provide additional protection against harmonic interference, while the heat-cured ASA-61 gray powder coating ensures long-term resistance to corrosion and environmental factors. The NEMA 2 enclosure offers protection against dust and light splashing, suitable for both indoor and outdoor installations. With a wide kVA range and flexible phase shift options, the Guard III HMT can be tailored to meet the specific demands of various applications, from small office buildings to large industrial facilities.
  • Three-phase, zig-zag secondary transformer for harmonic mitigation
  • Dual electrostatic shields and heat-cured ASA-61 gray powder coating
  • NEMA 2 enclosure for dust and light splashing protection
  • Available in 15-1500 kVA range with 0° and -30° phase shifts
  • UL and CSA Listed, qualified to IEEE-693-2005, IBC-2021, and CBC 2022 seismic standards

Specifications

Color
Gray
Connection Type
Zig-zag secondary
Current Rating
15-1500 kVA
Efficiency
DOE 2016
Enclosure
NEMA 2
Frequency
60 Hz
Frequency Rating
60 HZ
Ip Rating
NEMA 3R
K Factor
K1
KVA Rating
30 KVA
Material
Electrical Steel, Copper
Material
ASA-61 powder coating, electrical steel, copper
NEMA Rating
NEMA 3R
Phase
3
Poles
3-Phase
Primary Voltage
480 VAC
Secondary Voltage
208Y/120
Series
Guard III Harmonic Mitigating Transformers (HMT)
Series
Guard III HMT
Size
15-1500 kVA
Special Features
ABB's Guard III™ Harmonic Mitigating Transformers help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses. They maintain DOE2016 energy efficiency even when harmonics are present.
Standard
No
Temperature Rating
40 °C
Voltage Rating
480V/208Y/120V
Package Weight (Imperial)
0.001 L
Package Weight (Metric)
0.001 kg
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T76H9871G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T77H9876G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T76H9873G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T76H9875G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T76H9876G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T76H9874G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T77H9873G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

9T77H9874G03

ABB's Guard III Harmonic Mitigating Transformers (HMT) help eliminate harmonics, improve power quality, and help save energy by reducing the energy (heating) losses associated with harmonic activity. They maintain DOE 2016 energy efficiency even when harmonics are present. The HMT's are UL Listed and are available in common phase shifts with zigzag transformer secondaries. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.

Frequently Asked Questions

What kVA range does the Guard III HMT support?

The transformer is available in a kVA range from 15 to 1,500 kVA.

Is the Guard III HMT UL Listed?

Yes, the transformer is UL and CSA Listed.

What seismic standards does the Guard III HMT meet?

It is qualified to IEEE-693-2005, IBC-2021, and CBC 2022 seismic requirements.

What is the operating voltage range for the Guard III HMT?

The primary voltage is 480V, and the secondary voltage is 208Y/120V.

Does the Guard III HMT meet DOE 2016 energy efficiency standards?

Yes, it maintains DOE 2016 energy efficiency even under harmonic conditions.

What is the temperature rise rating for the Guard III HMT?

The transformer has a 150°C temperature rise rating.

Is the Guard III HMT suitable for outdoor installations?

Yes, it features a NEMA 3R enclosure for outdoor protection.

What materials are used in the construction of the Guard III HMT?

The transformer is constructed with high-quality electrical steel cores and copper windings.

What phase shifts are available for the Guard III HMT?

The transformer is available with 0° and -30° phase shifts to mitigate specific harmonics.

What insulation class does the Guard III HMT use?

The transformer uses a 220°C insulation class.

Frequently Asked Questions about ABB - Electrification

What industries and applications are Jokab Safety products used for?

Jokab Safety products are specifically designed for machine safety applications across multiple critical industrial sectors, including Food and Beverage, Packaging, and Material Handling industries. Their safety solutions cover a wide range of machine safeguarding needs, such as safety light guards, safety controllers, safety relays, safety edges, safety mats, and two-hand control devices that protect personnel and equipment in complex industrial automation environments.

What technical support does Jokab Safety offer?

Jokab Safety offers comprehensive technical support through multiple channels, including a dedicated technical support phone line at (888) 385-1221 (Option 1) and email support at [email protected]. For advanced technical assistance, customers can contact their specialized Jokab Tech Support at (519) 982-0976 or email [email protected]. Additionally, they provide product specialist support through Jeff Leslie, who can be reached at (519) 982-0976, offering in-depth application and technical guidance.

What are the main product lines offered by Jokab Safety?

Jokab Safety offers a comprehensive range of machine safety products including safety light guards (Orion), safety controllers (Pluto), safety relays (Sentry), safety edges, safety contact mats, safety locks (Gkey), and safety sensors with OSSD and DYNlink interfaces. Their product lines are specifically designed for industrial applications in food and beverage, packaging, and material handling industries, providing robust safety solutions for machine guarding and personnel protection.

What are the key features of Jokab Safety products?

Jokab Safety products offer comprehensive industrial safety solutions with key features including: highest safety certification levels (up to PL e/Cat 4), extensive fault detection, multiple safety device types (optical safety devices, pressure sensitive devices, sensors, switches, locks, emergency stops), and innovative DYNlink technology that reduces cable requirements and simplifies installation. Their products are certified, verified, and compatible with major industrial automation systems like B&R, featuring easy M12 connector connections and a wide range of adapters to streamline safety implementation.

What certifications and standards do ABB - Electrification products comply with?

ABB - Electrification products comply with a comprehensive range of international certifications and standards, including UL (United States), CSA (Canada), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia & New Zealand). Our products meet critical international standards such as IEC 60947 series for low-voltage switchgear, functional safety standards EN 61800-5-2 and ISO 13849-1, and marine classification standards from Bureau Veritas, DNV, and Lloyd's Register of Shipping.

What industries and applications are ABB - Electrification products used for?

ABB - Electrification products are engineered for critical applications across multiple industries, including Energy, Oil & Gas, Manufacturing, Power Generation, HVAC, Marine, Food & Beverage, Mining, Pulp & Paper, Water Treatment, and Automotive. Their solutions cover essential electrical infrastructure needs such as switchgear, power distribution systems, circuit protection, digital control technologies, and drive systems designed for high-reliability environments with a strong focus on sustainability, efficiency, and safety.

What technical support does ABB - Electrification offer?

ABB - Electrification offers comprehensive technical support through multiple channels, including a dedicated technical support hotline at 888-385-1221 (Option 1), available 7:00 a.m. - 5:00 p.m. CST, Monday-Friday. Their support services encompass 24/7/365 emergency services, on-site support, remote monitoring and diagnostics, installation and commissioning, equipment assessments, repair coordination, and multi-vendor technical assistance. Customers can also access resources like personnel safety training, disaster recovery support, and service agreements tailored to their specific electrification needs.

What are the main product lines offered by ABB - Electrification?

ABB - Electrification offers a comprehensive range of electrical distribution and protection products, including circuit monitoring systems, panelboards, switchgear, motor control centers, circuit breakers, softstarters, and power distribution solutions. Key product lines span low and medium voltage applications across utilities, commercial, industrial, healthcare, and manufacturing sectors, with specialized offerings like the ReliaGear® panelboards, SMISSLINE TP bus systems, and Ekip UP protection and metering relays.

What are the key features of ABB - Electrification products?

ABB - Electrification products feature advanced integrated design elements that enhance industrial performance and reliability. Key features include harmonics and EMC design, integrated DC choke, removable terminals for fast installation, USB ports for troubleshooting, and integrated Safe Torque Off (STO) functionality. The products deliver superior motor control capabilities, support both induction and permanent magnet motors, and offer robust operational features like side-by-side mounting without derating and operation at temperatures up to 45°C. Additionally, ABB's Electrification solutions emphasize digital innovation, with technologies like Novolink enabling predictive maintenance, enhanced analytics, and seamless system integration.

What communication protocols do ABB - Electrification products support?

ABB - Electrification products support a comprehensive range of industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, DeviceNet, and IEC 61850. These protocols enable flexible connectivity across multiple industrial automation platforms, with support for various network topologies and high-speed data transmission up to 100 Mbps.