ABB - Electrification Signature Partner Distributor
ABB - Electrification 9T21S1150 - ABB's Servicenter™ Single-Phase Integral Transformer and load center system comes equipped with an encapsulated transformer wired into rightly sized circuit breakers for both the primary and secondary transformer windings. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022. Accessible mounting flanges with keyhole slotted mounting holes to make installation easy. NEMA 3R painted enclosure. Clear, comprehensive documentation and labeling. The Servicenter system is UL Listed and is suitable for use service equipment with a 10 kAIC short circuit current rating. The load center portion of this system is ready to accept the ABB THQL plug-on circuit breakers.
More images
ABB - Electrification

9T21S1150

UPC: 783173012109


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The ABB Servicenter™ Single-Phase Integral Transformer and Load Center system (SKU: 9T21S1150) offers a consolidated power solution for industrial and temporary power needs. This unit integrates a 15 kVA single-phase transformer with pre-wired primary and secondary main circuit breakers into a load center compatible with ABB THQL plug-on circuit breakers. This design streamlines installation by eliminating separate component mounting and interconnections, reducing labor and material costs. The transformer features ABB's established design with a 180°C UL Recognized insulation system and a 115°C temperature rise. The load center incorporates the ABB ReliaHome™ circuit breaker load center interior. Engineered for reliability, the Servicenter™ meets seismic qualification requirements including IEEE-693-2005, IBC-2021, and CBC 2022. Installation is facilitated by accessible mounting flanges with keyhole slotted mounting holes. The NEMA 3R painted enclosure is suitable for both indoor and outdoor installations. The load center components provide a 10 kAIC short circuit current rating and utilize a copper bus for enhanced conductivity. Comprehensive documentation and clear labeling are included for ease of use and maintenance. This system is UL Listed to UL 1062 (YEFR:E75204) and complies with NEC Article 450-3, making it suitable for use as service equipment. Key Specifications for SKU 9T21S1150: - Transformer Rating: 15 kVA - Input Voltage: 480V - Output Voltage: 120/240V - Primary Main Breaker: 60A - Secondary Main Breaker: 70A - Branch Spaces: 12 total 1-pole spaces - Seismic Qualification: IEEE-693-2005, IBC-2021, CBC 2022 - Enclosure: NEMA 3R - Short Circuit Current Rating (SCCR): 10 kAIC - Listing: UL Listed to UL 1062 (YEFR:E75204) - Country of Origin: US - UNSPSC Code: 39121027
  • 15 kVA single-phase integral transformer and load center system (SKU: 9T21S1150)
  • Input: 480V, Output: 120/240V
  • Pre-wired primary (60A) and secondary (70A) main circuit breakers
  • 12 total 1-pole branch spaces for ABB THQL breakers
  • Seismic qualification: IEEE-693-2005, IBC-2021, CBC 2022
  • NEMA 3R painted enclosure for indoor/outdoor use
  • 10 kAIC short circuit current rating (SCCR)
  • UL Listed to UL 1062 (YEFR:E75204), suitable for service equipment
  • Accessible mounting flanges with keyhole slotted mounting holes for easy installation

Specifications

Connection Type
Plug-on Circuit Breakers (THQL)
Connection Type
Plug-on (THQL circuit breakers)
Current Rating
60 A / 70 A
Current Rating
60 A (primary) / 70 A (secondary)
Enclosure
NEMA 3R
Frequency
60 Hz
Frequency Rating
60 HZ
Frequency Rating, Maximum
60 Hz
Frequency Rating, Minimum
60 Hz
Input Voltage
480 VAC
Insulation
IS-12
KVA Rating
15 KVA
Material
Steel
Material
Copper Bus
Mounting Type
Keyhole Slotted Mounting Holes
Mounting Type
Keyhole Slotted Flanges
NEMA Rating
NEMA 3R
Output Voltage
120/240
Phase
1
Poles
12 (1-pole branch spaces)
Poles
12 (1-pole spaces)
Series
Servicenter
Special Features
This easily installed and serviceable unit incorporates a Type QMS transformer (single-phase) or a Type QL transformer (three-phase), a primary main circuit breaker, a secondary main circuit breaker, and a load-center-design breaker panel. Since these components don't have to be installed and interconnected separately, the contractor or user can reduce installation time and costs. Because of the single-unit concept, only one, handy Service center needs to be mounted. Keyhole mounting flange facilitates easy Mounting-Indoor and outdoor Use-Front - accessible, hinged or removable panel door-Heat barrier under core and coil provides added electrical and thermal isolation for wiring compartment-High-efficiency core construction-Factory installed and wired GE main and secondary main circuit breakers-Transformer, distribution panel and breakers are all designed, built and assembled by GE 21S1150
Standard
No
Temperature Rating
40 °C
Temperature Rating, Maximum
104 F
Temperature Rating, Maximum
40 C
Temperature Rating, Minimum
104 F
Temperature Rating, Minimum
40 C
Voltage Rating
480 VAC / 120/240 VAC
Wattage
15 KVA
Package Dimensions (L x W x H)
43.5 IN x 20.5 IN x 19.75 IN
Package Dimensions (L x W x H)
110.49 cm x 52.07 cm x 50.165 cm
Package Weight (Imperial)
280.000 L
Package Weight (Metric)
127.008 kg
ABB's Servicenter™ Single-Phase Integral Transformer and load center system comes equipped with an encapsulated transformer wired into rightly sized circuit breakers for both the primary and secondary transformer windings. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022. Accessible mounting flanges with keyhole slotted mounting holes to make installation easy. NEMA 3R painted enclosure. Clear, comprehensive documentation and labeling. The Servicenter system is UL Listed and is suitable for use service equipment with a 10 kAIC short circuit current rating. The load center portion of this system is ready to accept the ABB THQL plug-on circuit breakers.

9T21S1100

ABB's Servicenter™ Single-Phase Integral Transformer and load center system comes equipped with an encapsulated transformer wired into rightly sized circuit breakers for both the primary and secondary transformer windings. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022. Accessible mounting flanges with keyhole slotted mounting holes to make installation easy. NEMA 3R painted enclosure. Clear, comprehensive documentation and labeling. The Servicenter system is UL Listed and is suitable for use service equipment with a 10 kAIC short circuit current rating. The load center portion of this system is ready to accept the ABB THQL plug-on circuit breakers.
PowerMark Gold Meter Socket Load Centers are an ideal option for residential applications. Additonally, PowerMark Gold Meter Socket Load Centers provide increased reliability and maximum circuit layout flexibility. All our PowerMark Gold Meter Socket Load Centers are built with high-quality materials for extended durability. Furthermore, their perfected design allows for an easy and fast installation. The TM2432RMS is a dual main breaker meter socket with a ring and features spaces for 24, 1" breakers, a 320 A main ampere rating, and an outdoor surf/semi enclosure.

TM2432RMS

PowerMark Gold Meter Socket Load Centers are an ideal option for residential applications. Additonally, PowerMark Gold Meter Socket Load Centers provide increased reliability and maximum circuit layout flexibility. All our PowerMark Gold Meter Socket Load Centers are built with high-quality materials for extended durability. Furthermore, their perfected design allows for an easy and fast installation. The TM2432RMS is a dual main breaker meter socket with a ring and features spaces for 24, 1" breakers, a 320 A main ampere rating, and an outdoor surf/semi enclosure.
Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL42422R features space for 42, 1" breakers, 3 phases, a 225 A bus ampere rating, and an outdoor suitable enclosure.

TL42422R

Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL42422R features space for 42, 1" breakers, 3 phases, a 225 A bus ampere rating, and an outdoor suitable enclosure.
Main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM42422R features spaces for 42, 1" breakers, a 225A main ampere rating, 3 phases, and an outdoor suitable enclosure.

TM42422R

Main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM42422R features spaces for 42, 1" breakers, a 225A main ampere rating, 3 phases, and an outdoor suitable enclosure.
PowerMark Gold main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM2010RCU features spaces for 20, 1" breakers, a 100 A bus ampere rating, a copper bus, and an outdoor suitable enclosure.

TM2010RCU

PowerMark Gold main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM2010RCU features spaces for 20, 1" breakers, a 100 A bus ampere rating, a copper bus, and an outdoor suitable enclosure.
PowerMark Gold main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM2415RCU features spaces for 24, 1" breakers, a 150 A bus ampere rating, a copper bus, and an outdoor suitable enclosure.

TM2415RCU

PowerMark Gold main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM2415RCU features spaces for 24, 1" breakers, a 150 A bus ampere rating, a copper bus, and an outdoor suitable enclosure.
PowerMark Gold main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM1615CCUG features spaces for 16, 1" breakers, a 150 A main ampere rating, a copper bus, a factory installed ground bar, and a combination surface/flush enclosure.

TM1615CCUG

PowerMark Gold main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM1615CCUG features spaces for 16, 1" breakers, a 150 A main ampere rating, a copper bus, a factory installed ground bar, and a combination surface/flush enclosure.
PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM2415RCU features space for 24, 1" breakers, a 150 A bus ampere rating, a copper bus, and an outdoor suitable enclosure.

TLM2415RCU

PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM2415RCU features space for 24, 1" breakers, a 150 A bus ampere rating, a copper bus, and an outdoor suitable enclosure.

Frequently Asked Questions

What type of transformer is used in the 9T21S1150?

The 9T21S1150 uses a 406 type, single phase, encapsulated transformer.

What are the primary and secondary voltage ratings?

The primary voltage is 480V and the secondary voltage is 240V.

What is the KVA rating of the transformer?

The transformer has a KVA rating of 75 KVA.

What is the enclosure type and rating?

The enclosure is NEMA 3R painted.

Is the 9T21S1150 UL Listed?

Yes, the Servicenter system is UL Listed.

What type of circuit breakers can be used with the load center?

The load center is ready to accept ABB THQL plug-on circuit breakers.

What is the frequency rating?

The frequency rating is 60 Hz.

What is the coil material?

The coil material is AL.

What standards does the 9T21S1150 meet?

It is qualified to the seismic requirements of IEEE 693 and IBC 2009.

What is the short circuit current rating?

The system is suitable for use with service equipment with a 10 K AIC short circuit current rating.

Frequently Asked Questions about ABB - Electrification

What industries and applications are Jokab Safety products used for?

Jokab Safety products are specifically designed for machine safety applications across multiple critical industrial sectors, including Food and Beverage, Packaging, and Material Handling industries. Their safety solutions cover a wide range of machine safeguarding needs, such as safety light guards, safety controllers, safety relays, safety edges, safety mats, and two-hand control devices that protect personnel and equipment in complex industrial automation environments.

What technical support does Jokab Safety offer?

Jokab Safety offers comprehensive technical support through multiple channels, including a dedicated technical support phone line at (888) 385-1221 (Option 1) and email support at [email protected]. For advanced technical assistance, customers can contact their specialized Jokab Tech Support at (519) 982-0976 or email [email protected]. Additionally, they provide product specialist support through Jeff Leslie, who can be reached at (519) 982-0976, offering in-depth application and technical guidance.

What are the main product lines offered by Jokab Safety?

Jokab Safety offers a comprehensive range of machine safety products including safety light guards (Orion), safety controllers (Pluto), safety relays (Sentry), safety edges, safety contact mats, safety locks (Gkey), and safety sensors with OSSD and DYNlink interfaces. Their product lines are specifically designed for industrial applications in food and beverage, packaging, and material handling industries, providing robust safety solutions for machine guarding and personnel protection.

What are the key features of Jokab Safety products?

Jokab Safety products offer comprehensive industrial safety solutions with key features including: highest safety certification levels (up to PL e/Cat 4), extensive fault detection, multiple safety device types (optical safety devices, pressure sensitive devices, sensors, switches, locks, emergency stops), and innovative DYNlink technology that reduces cable requirements and simplifies installation. Their products are certified, verified, and compatible with major industrial automation systems like B&R, featuring easy M12 connector connections and a wide range of adapters to streamline safety implementation.

What certifications and standards do ABB - Electrification products comply with?

ABB - Electrification products comply with a comprehensive range of international certifications and standards, including UL (United States), CSA (Canada), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia & New Zealand). Our products meet critical international standards such as IEC 60947 series for low-voltage switchgear, functional safety standards EN 61800-5-2 and ISO 13849-1, and marine classification standards from Bureau Veritas, DNV, and Lloyd's Register of Shipping.

What industries and applications are ABB - Electrification products used for?

ABB - Electrification products are engineered for critical applications across multiple industries, including Energy, Oil & Gas, Manufacturing, Power Generation, HVAC, Marine, Food & Beverage, Mining, Pulp & Paper, Water Treatment, and Automotive. Their solutions cover essential electrical infrastructure needs such as switchgear, power distribution systems, circuit protection, digital control technologies, and drive systems designed for high-reliability environments with a strong focus on sustainability, efficiency, and safety.

What technical support does ABB - Electrification offer?

ABB - Electrification offers comprehensive technical support through multiple channels, including a dedicated technical support hotline at 888-385-1221 (Option 1), available 7:00 a.m. - 5:00 p.m. CST, Monday-Friday. Their support services encompass 24/7/365 emergency services, on-site support, remote monitoring and diagnostics, installation and commissioning, equipment assessments, repair coordination, and multi-vendor technical assistance. Customers can also access resources like personnel safety training, disaster recovery support, and service agreements tailored to their specific electrification needs.

What are the main product lines offered by ABB - Electrification?

ABB - Electrification offers a comprehensive range of electrical distribution and protection products, including circuit monitoring systems, panelboards, switchgear, motor control centers, circuit breakers, softstarters, and power distribution solutions. Key product lines span low and medium voltage applications across utilities, commercial, industrial, healthcare, and manufacturing sectors, with specialized offerings like the ReliaGear® panelboards, SMISSLINE TP bus systems, and Ekip UP protection and metering relays.

What are the key features of ABB - Electrification products?

ABB - Electrification products feature advanced integrated design elements that enhance industrial performance and reliability. Key features include harmonics and EMC design, integrated DC choke, removable terminals for fast installation, USB ports for troubleshooting, and integrated Safe Torque Off (STO) functionality. The products deliver superior motor control capabilities, support both induction and permanent magnet motors, and offer robust operational features like side-by-side mounting without derating and operation at temperatures up to 45°C. Additionally, ABB's Electrification solutions emphasize digital innovation, with technologies like Novolink enabling predictive maintenance, enhanced analytics, and seamless system integration.

What communication protocols do ABB - Electrification products support?

ABB - Electrification products support a comprehensive range of industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, DeviceNet, and IEC 61850. These protocols enable flexible connectivity across multiple industrial automation platforms, with support for various network topologies and high-speed data transmission up to 100 Mbps.