Power Break II Products
Power Break II is a brand of ABB - Electrification. Gross Automation stocks 37 Power Break II products across Switch Part Or Accessory, Mounting Kits, Protection Relay.

ABB - Electrification · GE · Power Break II
SPUV120ACR
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 0ACR Frame Rating Amps 2500
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPDOSD36S
Control wiring is connected through drawout secondary disconnects in the "TEST" and "CONNECTED" positions only. Up to 72 control circuits are possible through 36 position plug-style secondary disconnects mounted to each side of drawout breakers. One substructure disconnect (SPDOSD36S) must be ordered for each breaker when accessories or communications are used. When auxiliary switches are used along with any other electrical accessory or communications, two disconnects must be ordered. SD36S
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS600AB4DR
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. SPAS600A
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS240AB8DR
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. AB8DR
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS240AB12DR
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. SPAS240A
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS240AB12R
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. AB12R
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS240AB4DR
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. AB4DR
Contact for Pricing

ABB - Electrification · GE · Power Break II
TSLUG20
Kit accepts Cu/Al wire and requires the use of T-studs. UG20 Amps 2000 A
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS600AB8DR
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. AB8DR
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPE024R
The electrical operator mounts inside the front cover of the manually operated breaker. The accessory can be added to any Power Break II breaker in the factory or the field to provide electrical spring charging and charge indication. For remote closing, the remote close solenoid must be priced and ordered separately. All breakers are prewired to dedicated secondary terminals for easy field installation. When electrical operation is used, either a shunt trip or an undervoltage release accessory is required for remote opening. These accessories must be ordered and priced separately. 024R Frame Rating Amps 2500
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS240AB4R
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. 0AB4R
Contact for Pricing

ABB - Electrification · GE · Power Break II
TSLUG12
Kit accepts Cu/Al wire and requires the use of T-studs. UG12 Amps 1200 A
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPUV048DCR
The undervoltage release is an electronic module used to open the circuit breaker when the monitored voltage drops below 35-60PERC of its rated value. The undervoltage release "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose (the sealing voltage of the UVR is 60-85PERC of its rated voltage). An undervoltage release trip operation is produced by the MicroVersaTrip½ Plus unit in response to a signal from the undervoltage release module. This allows the trip unit to record, display, distinguish an d comm un icate (in MicroVer saTri p½ PM trip units) that the breaker opening event was due to undervoltage release. Operation of the undervoltage release module will prevent breaker contact closure, i.e. "kiss-free" operation. When energized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display. Field installable. 8DCR Frame Rating Amps 1600
Contact for Pricing

ABB - Electrification · GE · Power Break II
SP20FCC
T-studs mount directly to the breaker and can be rotated for either vertical or horizontal bus connection. 4000 ampere T-studs are for vertical bus bars only. Catalog number includes one stud. Both copper and aluminum T-studs are tin plated. 0FCC Frame Rating Amps 3000
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPRCS024R
This accessory provides an electrically operated solenoid, which, when energized, closes the breaker. It is suitable for control interlock schemes in which manual closing capability would not be convenient or desirable. The breaker is provided with a manual close button which can be replaced by the Hidden "ON" Button accessory and/or sealed using the Limited Access Pushbutton Cover accessory. The remote closing accessory is continuously rated and has an anti-pump feature which prevents a motor operated breaker from repeatedly closing into a fault. Closing control voltage must be removed and re-applied for each breaker closure. 024R Frame Rating Amps 800
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPBAL600R
The bell alarm with lockout module combines both the bell alram and a manual lockout function. The bell alarm switch provides remote indication of whether the circuit breaker has been tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off" circuit breaker operation and during operation by the push to trip button. Upon occurrence of a trip event, a mechanical pop-out target must be manually reset before the breaker can be reclosed.
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPCOUNTERR
The Mechanical Operations Counter is mounted behind the front cover of the breaker. It is viewable through a rectangular knockout window opening in the breaker cover. It is a five digit, non-resettable counter which is actuated each time the breaker is opened by any means.
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPE120R
The electrical operator mounts inside the front cover of the manually operated breaker. The accessory can be added to any Power Break II breaker in the factory or the field to provide electrical spring charging and charge indication. For remote closing, the remote close solenoid must be priced and ordered separately. All breakers are prewired to dedicated secondary terminals for easy field installation. When electrical operation is used, either a shunt trip or an undervoltage release accessory is required for remote opening. These accessories must be ordered and priced separately. 120R Frame Rating Amps 2500
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPE125R
The electrical operator mounts inside the front cover of the manually operated breaker. The accessory can be added to any Power Break II breaker in the factory or the field to provide electrical spring charging and charge indication. For remote closing, the remote close solenoid must be priced and ordered separately. All breakers are prewired to dedicated secondary terminals for easy field installation. When electrical operation is used, either a shunt trip or an undervoltage release accessory is required for remote opening. These accessories must be ordered and priced separately. 125R Frame Rating Amps 4000
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS600AB4R
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. 0AB4R
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPRCS120R
This accessory provides an electrically operated solenoid, which, when energized, closes the breaker. It is suitable for control interlock schemes in which manual closing capability would not be convenient or desirable. The breaker is provided with a manual close button which can be replaced by the Hidden "ON" Button accessory and/or sealed using the Limited Access Pushbutton Cover accessory. The remote closing accessory is continuously rated and has an anti-pump feature which prevents a motor operated breaker from repeatedly closing into a fault. Closing control voltage must be removed and re-applied for each breaker closure. 120R Frame Rating Amps 1600
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPAS240AB8R
Auxiliary switches provide remote indication of whether the circuit breaker main contacts are opened or closed via open or closed SPDT elements. 0AB8R
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPRCS125R
This accessory provides an electrically operated solenoid, which, when energized, closes the breaker. It is suitable for control interlock schemes in which manual closing capability would not be convenient or desirable. The breaker is provided with a manual close button which can be replaced by the Hidden "ON" Button accessory and/or sealed using the Limited Access Pushbutton Cover accessory. The remote closing accessory is continuously rated and has an anti-pump feature which prevents a motor operated breaker from repeatedly closing into a fault. Closing control voltage must be removed and re-applied for each breaker closure. 125R Frame Rating Amps 1600
Contact for Pricing

ABB - Electrification · GE · Power Break II
SPBAA240R
The bell alarm switch provides remote indication of whether the circuit breaker has been tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off" circuit breaker operation and during operation by the push to trip button. 240R Frame Rating Amps 4000
Contact for Pricing