Littelfuse · PGR 6800 Series
PGR-6803-240
PUMP RELAY 90A, BUILT-IN CTS, 240VAC. The PGR-6800 Pump Protection Relay provides protection for pumps with three-phase motors up to 1,000 Vac. No current transformers are required for currents up to 91 A. The protective functions include overload, phase unbalance, phase loss, phase sequence and undercurrent. The PGR-6800 Pump Protection Relay is ideally suited for applications where operating without load can induce failure. Motor current is monitored and an undercurrent trip occurs when the current drops below a preset level. No additional level detectors are required.
Contact for Pricing

Littelfuse · PGB-6130 Series
PGB-6130
REMOTE INDICATION / RESET FOR PGR-6130. For use with PGR-6130. Remote indication of overcurrent, phase imbalance, phase loss, phase sequence, and overtemperature. Remote reset included.
Contact for Pricing

Littelfuse · PGC 6000 Series
PGC-6080
EARTH FAULT CT, 3.1 ID (80MM). Current transformer for measuring ground-fault current.
Contact for Pricing

All Littelfuse Class G fuse blocks offer snap-to-release DIN rail mounting and universal mounting holes. Class G fuse blocks are designed for use with time-delay current limiting Class G fuses.
Contact for Pricing

Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.
Contact for Pricing

Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.
Contact for Pricing

FUSE CLIP 11506. Thru-Hole Holders for 2AG or 4.5-5mm Diameter Fuses
Contact for Pricing
Minimum Qty: 2000
Multiplier: 2000
*Contact for lower quantities*

FUSE CLIP 29001. Rivet/Eyelet Mount Fuse Clips for 13/16” Dia. Fuses.
Contact for Pricing

Littelfuse fuseblock covers protect personnel from accidentally coming into contact with energized parts. Covers are for use with various UL class fuseblocks. Please, review the ordering information for available covers.
Contact for Pricing

POWR-BLOKS power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or splitting primary power into secondary circuits. LX2XXX-DIN series offers integral DIN-Rail mount and an optional hinged safety cover. Applications: Typical applications include heating, air conditioning and refrigeration systems, elevator systems, material handling equipment, control panels, motor controls, switchgear, and anywhere power needs to be distributed to more than one load.
Contact for Pricing

POWR-BLOK covers provide protection against accidental shorting between poles caused by loose wires, tools, or other conductive material. They also protect personnel from accidentally contacting energized connectors. To order protective covers, match the number of poles for the block to the cover.
Contact for Pricing

The MPU-32-01-00 is a motor protection unit with a supply voltage between 65–265 V ac and 80–275 V dc. This unit provides current and temperature-based protection with communication via RS/TIA-232-RS/TIA-485.
Contact for Pricing