Showing 169-180 of 278 results

Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

Contact for Pricing

Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

The FA and FS Series Flashers have proven their reliability through years of use on communication towers, smoke stacks, cooling towers, tall buildings, bridges and utility towers. The highest quality components are encapsulated in a rugged plastic housing with a molded-in heat transfer plate. The flash rate, ratio, and failsafe design meet FAA regulations. Zero voltage switching can increase lamp life up to ten times. The FS155-30RF & FS165-30RF include superior RF filtering circuitry for use in high RF installations, including AM hot towers. Operation: FS Series - Flasher (OFF First), FA Series - Flashers & Aux. Modules: Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until voltage is removed. Reset: Removing input voltage resets the output and the sequence to T2.
Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*

The ECS Series of single-phase AC current sensors is a universal, overcurrent or undercurrent sensing control. Its built-in toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for current sensing mode, trip point, and trip delay. Detects over or undercurrent events like locked rotor, loss of load, an open heater or lamp load, or proves an operation is taking place or has ended. Operation: Input voltage must be supplied at all times for proper operation. When a fault is sensed throughout the trip delay, the output relay is energized. When the current returns to the normal run condition or zero, the output and the delay are reset. If a fault is sensed and then corrected before the trip delay is completed, the relay will not energize and the trip delay is reset to zero.
Contact for Pricing

The ECS Series of single-phase AC current sensors is a universal, overcurrent or undercurrent sensing control. Its built-in toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for current sensing mode, trip point, and trip delay. Detects over or undercurrent events like locked rotor, loss of load, an open heater or lamp load, or proves an operation is taking place or has ended. Operation: Input voltage must be supplied at all times for proper operation. When a fault is sensed throughout the trip delay, the output relay is energized. When the current returns to the normal run condition or zero, the output and the delay are reset. If a fault is sensed and then corrected before the trip delay is completed, the relay will not energize and the trip delay is reset to zero.
Contact for Pricing

The PHS120A10 relay provides phase control protection with input voltage at 120 V ac and output load rating at steady state (100% on) of 10 A; inrush of 100 A.
Contact for Pricing

The PHS120A20 relay provides phase control protection with input voltage at 120 V ac and output load rating at steady state (100% on) of 20 A; inrush of 200 A.
Contact for Pricing