Accessories

    Drives, Servos, and Motors

    Enclosures, Fans, and Environmental Controls

    Laboratory and Measuring and Observing and Testing Equipment

    Industrial Manufacturing and Processing Machinery and Accessories

    Safety Equipment and Supplies

    Miscellaneous

    Distribution and Conditioning Systems and Equipment and Components

    Information Technology Broadcasting and Telecommunications

    Tools and General Machinery

    Manufacturing Components and Supplies

    Structures, Building, and Construction

    Power Generation and Distribution Machinery and Accessories

    Electronic Components And Supplies

    Material Handling and Conditioning and Storage Machinery and their Accessories and Supplies

    Office Equipment and Accessories and Supplies

    Electrical Systems and Lighting and Components and Accessories and Supplies

Showing 1129-1140 of 1,783 results

Mersen Y216106 - The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 30 amps NDZ gG fuse .
Mersen · Ferraz Shawmut

Y216106

4086500061839


The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 30 amps NDZ gG fuse .

Contact for Pricing

Minimum Qty: 25

Multiplier: 25

*Contact for lower quantities*

Mersen N216626 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 125 amps NH00 1 pole Linocur fuse base .
Mersen · Ferraz Shawmut

N216626

4086500038596


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 125 amps NH00 1 pole Linocur fuse base .

Contact for Pricing

Mersen N216580 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 250 amps NH GI series masking frame .
Mersen · Ferraz Shawmut

N216580

4086500034710


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 250 amps NH GI series masking frame .

Contact for Pricing

Mersen E217124 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 250 amps NH1 1 pole screw terminal fuse base .
Mersen · Ferraz Shawmut

E217124

4086500052851


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 250 amps NH1 1 pole screw terminal fuse base .

Contact for Pricing

Minimum Qty: 3

Multiplier: 3

*Contact for lower quantities*

Mersen G214573 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 160 amps NH00 1 pole screw terminal fuse base .
Mersen · Ferraz Shawmut

G214573

4086500052769


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 160 amps NH00 1 pole screw terminal fuse base .

Contact for Pricing

Minimum Qty: 3

Multiplier: 3

*Contact for lower quantities*

Mersen N214579 - The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 63 amps DIII 3 pole fuse base with clamp terminals with neutral clamp .
Mersen · Ferraz Shawmut

N214579

4086500054152


The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 500 Volts 63 amps DIII 3 pole fuse base with clamp terminals with neutral clamp .

Contact for Pricing

Minimum Qty: 8

Multiplier: 8

*Contact for lower quantities*

Mersen J218117 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. D02 to D03
Mersen · Ferraz Shawmut

J218117

4086500055081


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. D02 to D03

Contact for Pricing

Minimum Qty: 100

Multiplier: 100

*Contact for lower quantities*

Mersen Y219717 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 160 amps NH00 terminal cover .
Mersen · Ferraz Shawmut

Y219717

4086500053025


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 160 amps NH00 terminal cover .

Contact for Pricing

Minimum Qty: 20

Multiplier: 20

*Contact for lower quantities*

Mersen R215042 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 1 pole Linozed fuse base .
Mersen · Ferraz Shawmut

R215042

4086500054213


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 1 pole Linozed fuse base .

Contact for Pricing

Minimum Qty: 6

Multiplier: 6

*Contact for lower quantities*

Mersen W222935 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 25 amps NH00 and NH000 3 Pole Masking Frame .
Mersen · Ferraz Shawmut

W222935

4086500055760


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 500 Volts 25 amps NH00 and NH000 3 Pole Masking Frame .

Contact for Pricing

Minimum Qty: 10

Multiplier: 10

*Contact for lower quantities*

Mersen T212997 - The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 100 kVA gTR NH4a series.
Mersen · Ferraz Shawmut

T212997

4086500061617


The NH system is classified among plug-in fuse systems and is composed of: • fuse-base, (possibly including terminal covers and phase barriers) • fuse-link with blade contact • fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1×3 times nominal current for up to 10 hours. The fuse link operates at 1×5 times nominal transformer current within 2 hours. 400 Volts 100 kVA gTR NH4a series.

Contact for Pricing

Mersen T219690 - The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 3P Linocur fuse base series.
Mersen · Ferraz Shawmut

T219690

4086500054466


The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links gG also protect equipments and installations against dynamic effects of high short circuit currents. 400 Volts 63 amps D02 3P Linocur fuse base series.

Contact for Pricing

Showing 1129-1140 of 1,783 results