Contact for Pricing
Overview
- Enclosure provides modern, flat-screen monitor-style aesthetics
- Integrated side handles allow for easy repositioning of enclosure
- Fully concealed silicone gasket area provides complete protection in washdown environments
- 20-degree sloped top facilitates runoff of water and cleaning solutions and prohibits the placement of objects on the top of the enclosure
- Slanted flange trough collar prohibits pooling of fluids along the top edge of the enclosure opening
- Enclosure can be flipped for either pendant or pedestal mounting
- Hinges are shielded by door
- Suspension arm adapter included to attach to Syspend Sanitary Suspension System and Syspend VHDS-Motion Arm
- Suspension arm adapter can be installed backwards to provide 40-degree tilt for pedestal applications
- Internal support plate provides extra rigidity for suspension mounting
Specifications
Application | Corrosive Environments; Hygienic Environments; Controls and Drives |
Color | Unpainted |
Depth | 5.91 |
Depth | 150 |
Depth | 150 mm |
Finish | Brushed #3 |
Height | 19.68 |
Height | 500 |
Height | 500 mm |
IP Rating | IP66 |
Material | SS Type 304 |
Material | Stainless Steel 304 |
Modification Services | No |
NEMA Rating | 4X Watertight, corrosion-resistant |
Product Family | Syspend |
Protection Rating | NEMA Type 12 |
Size | 19.69x19.69x5.91 in |
Steel Panel | A16P10 |
Thickness | 1.2 mm |
Thickness | 18 ga |
Type | HMI Enclosure Systems |
Type Number | Type 3R |
Weight | 34 lb |
Weight | 12.2 kg |
Width | 500 mm |
Width | 19.68 |
Width | 500 |
Package Dimensions (L x W x H) | 26.25 IN x 25.75 IN x 12.75 IN |
Package Dimensions (L x W x H) | 66.675 cm x 65.405 cm x 32.385 cm |
Package Weight (Imperial) | 34.000 L |
Package Weight (Metric) | 15.422 kg |
How to Install the S505015SS Controller
This guide provides step-by-step instructions for installing and configuring the S505015SS Controller on a DIN rail.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the controller
Secure the S505015SS controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.
- Connect the power supply
Using terminal connectors, connect the power supply wires to the designated input terminals on the controller. Ensure correct polarity to avoid damage.
- Verify connections
Use a multimeter to check the voltage at the power input terminals. Confirm that the voltage matches the specifications outlined in the controller's manual.
- Configure initial settings
Access the controller's configuration interface and set the desired parameters according to your application requirements.
- Calibrate the controller
Follow the calibration procedure in the manual to ensure the controller operates accurately within the specified range.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.