Overview
- The Vertical Cable Manager I is used for routing and bundling cable inside cabinets
- In order to achieve a full vertical runway on 1800-mm or taller enclosures, two units must be stacked
- Wireform gate hinges open to ease wire routing
- Mounts to grid strap or frame in front of rack angles
- Narrow profile does not interfere with 19-inch equipment in 600-mm wide enclosures
Specifications
Application | Networking, Storage and Data Center |
Color | Jet Black |
Color | Black |
Color Code | RAL 9005 |
Finish | Powder Coated |
Material | Mild Steel |
Material | Mild Steel;Steel |
Modification Services | Yes |
Product Family | ProLine |
Thickness | 51.40mm (2.024") |
Thickness | 16 ga |
Thickness | 1.52 mm |
Type | Rack and Cabinet Cable Management |
Weight | 4.4 lb |
Package Dimensions (L x W x H) | 33 IN x 6.5 IN x 4.3 IN |
Package Dimensions (L x W x H) | 83.82 cm x 16.51 cm x 10.922 cm |
Package Weight (Imperial) | 4.400 L |
Package Weight (Metric) | 1.996 kg |
How to Install the Vertical Cable Manager for 600mm Wide Cabinets
This guide provides step-by-step instructions for installing the Vertical Cable Manager in 600mm wide cabinets, ensuring proper mounting and secure connections.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the cable manager to the frame
Secure the cable manager to the cabinet frame using the provided M5–10 mounting screws. Ensure it is aligned properly and securely fastened.
- Connect the cable manager to grid straps
Attach the cable manager to the grid straps using the appropriate mounting hardware. Make sure the connections are tight to prevent any movement.
- Verify the installation
Check that the cable manager is level and securely mounted. Use a multimeter to ensure that all connections are properly established and there are no short circuits.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.