nVent PPF2010G - Full Subpanel, 2000x1000, Conductive, Steel
nVent

PPF2010G

UPC: 783510263690


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent ProLine Full Subpanel (PPF2010G)** is a high-performance, conductive steel subpanel engineered for industrial and commercial electrical enclosures. Measuring 2000x1000mm, this full-depth subpanel provides unmatched structural integrity while optimizing space for complex wiring configurations. Designed for seamless integration with ProLine enclosures, it ensures maximum panel depth and ease of installation, making it an ideal choice for professionals who demand reliability and efficiency in demanding environments. **Key Features & Benefits:** - **Full Subpanel Design:** Unlike partial subpanels, the PPF2010G spans the entire enclosure depth, offering superior support for heavy-duty components and reducing vibration risks. This design is critical in high-vibration industrial settings such as manufacturing plants, power distribution centers, and data centers. - **Conductive Steel Construction:** The steel material ensures optimal electrical conductivity, making it suitable for grounding applications and EMI shielding in sensitive electronic environments. This is particularly valuable in industries like telecommunications, renewable energy, and automation, where stable grounding is essential for safety and performance. - **Nylon Glide Blocks for Effortless Installation:** The subpanel slides into the enclosure frame on durable nylon glide blocks, which distribute the entire weight evenly. This feature eliminates the need for additional support structures, reducing installation time by up to 40% compared to traditional mounting methods. Professionals in fast-paced construction or retrofitting projects will appreciate the time-saving convenience. - **Compatibility with ProLine Enclosures:** As part of the ProLine series, the PPF2010G is engineered to integrate flawlessly with nVent’s ProLine enclosure systems. This compatibility ensures a secure fit, minimizing gaps and enhancing thermal management—critical for maintaining optimal operating temperatures in high-power applications. - **Versatile Applications:** From industrial control panels and motor control centers to renewable energy inverters and telecommunications hubs, the PPF2010G adapts to a wide range of environments. Its robust construction and conductive properties make it a preferred choice for engineers and electricians working in sectors where durability and electrical performance are non-negotiable. **Why Choose nVent for Subpanels?** nVent is a trusted leader in thermal management and electrical protection solutions, with decades of expertise in designing products that meet the rigorous demands of industrial applications. The ProLine series, including the PPF2010G, reflects nVent’s commitment to innovation, quality, and compliance with industry standards such as UL, NEMA, and IEC. Whether you’re outfitting a new facility or upgrading an existing system, nVent’s subpanels deliver the performance and reliability professionals rely on. **Installation & Maintenance Considerations:** Installation of the PPF2010G is straightforward, thanks to its modular design and pre-drilled mounting holes. The conductive steel ensures long-term corrosion resistance, while the nylon glide blocks reduce wear and tear over time. For optimal performance, ensure the enclosure is properly ventilated and that the subpanel is securely fastened to prevent misalignment during operation. Regular inspections for signs of stress or corrosion will extend the subpanel’s lifespan, making it a cost-effective investment for any electrical infrastructure.
  • All necessary mounting hardware is included
  • Subpanels have flanges on all sides
  • Subpanels can be mounted at nearly any depth in 25-mm increments
  • Panels installed in the rearmost position in joined (ganged) enclosures provide a continuous mounting surface without requiring joining panels
  • Mounting hardware attaches to the top or to the sides of the frame
  • Subpanels are 12 gauge (2.5 mm); Double-bay subpanels are 11 gauge (3.0 mm) for all frames 1400mm in height or greater
  • Subpanels are available standard in either conductive or white painted finish
  • Additional Mounting Hardware (PMKPF) for securing panel to frame in the center of the subpanel is sold separately

Specifications

Application
Power Distribution; Controls and Drives
Color
Unpainted
Finish
Galvanized
Material
Mild Steel
Modification Services
Yes
Product Family
ProLine
Size
78.74 x 39.37 in
Thickness
12 ga
Thickness
2.66 mm
Type
Internal Mounting for ProLine Industrial Enclosures
Weight
94 lb
Package Dimensions (L x W x H)
74 IN x 37 IN x 2.75 IN
Package Dimensions (L x W x H)
187.96 cm x 93.98 cm x 6.985 cm
Package Weight (Imperial)
94.000 L
Package Weight (Metric)
42.638 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the PPF188 Controller

This guide provides step-by-step instructions for mounting, wiring, and configuring the PPF188 Controller.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the PPF188 Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power and signal wires to the appropriate terminals on the PPF188 Controller. Ensure all connections are secure to prevent short circuits.

  3. Verify the installation

    Use a multimeter to check the voltage at the power terminals to ensure the controller is receiving the correct voltage. If the voltage is outside the specified range, recheck your connections.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.