nVent PPB1166 - ProLine 100-mm Plinth Base, fits 1600x600mm, Black, Steel
nVent

PPB1166

UPC: 783510234690


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent ProLine 100-mm Plinth Base (SKU: PPB1166)** is a robust, cast aluminum corner-supported base designed to elevate and protect industrial enclosures while providing secure cable entry points. Engineered for enclosures measuring 1600x600mm, this plinth base ensures compliance with Type 12 protection standards when paired with a compatible gland plate system, making it ideal for harsh industrial environments. Manufactured in the US by nVent—a trusted leader in thermal management and electrical protection solutions—the ProLine Plinth Base combines durability, modularity, and ease of installation to streamline enclosure setups in demanding applications. **Key Features and Benefits:** - **Structural Integrity:** Four cast aluminum corner supports provide exceptional load-bearing capacity, ensuring stability for heavy enclosures in manufacturing plants, data centers, and utility facilities. - **Modular Design:** Includes four access panels that attach securely with screws, allowing for flexible cable routing and future modifications without dismantling the entire structure. - **Cable Management:** The 100-mm height creates essential clearance for cables to enter from below, reducing clutter and improving airflow around the enclosure. - **Corrosion Resistance:** Black steel construction resists corrosion, making it suitable for outdoor installations or facilities with high humidity or chemical exposure. - **Compliance Ready:** When used with a gland plate system (sold separately), the plinth base meets Type 12 (IP54 equivalent) protection standards, safeguarding against dust and water ingress. **Industry Applications:** The nVent ProLine Plinth Base is widely used in sectors where equipment protection and cable organization are critical. Common applications include: - **Manufacturing Facilities:** Supports control panels, PLCs, and motor starters while managing extensive cabling in automated production lines. - **Data Centers:** Elevates server racks and networking cabinets to improve cooling efficiency and simplify cable management for IT infrastructure. - **Utilities & Energy:** Protects electrical distribution panels and switchgear in substations, wind farms, and solar installations. - **Oil & Gas:** Ensures durable, weather-resistant housing for instrumentation and control systems in refineries and offshore platforms. - **Commercial Buildings:** Enhances the aesthetics and functionality of electrical rooms and telecom closets in office complexes and retail spaces. **Installation and Selection Guidance:** Professionals choose the ProLine Plinth Base for its compatibility with standard enclosure sizes and its ability to integrate seamlessly with nVent’s ProLine product line. Installation is straightforward: the corner supports are pre-drilled for alignment, and all mounting hardware is included. For optimal performance, pair the base with nVent’s gland plate systems to achieve Type 12 protection. When selecting a plinth base, consider the enclosure’s weight, environmental conditions, and required ingress protection level. The ProLine series is favored for its consistency with nVent’s high-quality manufacturing standards, ensuring long-term reliability in mission-critical applications. **Why Choose nVent?** nVent is a global leader in electrical and thermal management solutions, known for innovation and durability. With decades of experience in industrial protection systems, nVent’s ProLine series reflects the company’s commitment to engineering products that meet the rigorous demands of modern facilities. The ProLine 100-mm Plinth Base exemplifies this dedication, offering a balance of strength, flexibility, and compliance-ready design. For engineers and facility managers seeking a dependable foundation for their enclosures, the nVent ProLine Plinth Base delivers unmatched performance and peace of mind.
  • All necessary mounting hardware included
  • Order with a gland plate system to provide Type 12 protection when using a Plinth Base
  • Modular access panels for flexible cable routing
  • Compatible with gland plate systems for Type 12 protection
  • Black steel construction resists corrosion and weathering

Specifications

Application
Power Distribution; Controls and Drives
Color
Jet Black
Color
Black
Color Code
RAL 9005
Finish
Powder Coated
Fits Frame
1600 x 600 mm
IP Rating
IP54
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
Corner supports with screws
Nema Rating
Type 12
Product Family
ProLine
Series
ProLine
Size
fits 1600x600mm
Size
100mm
Size
1600x600mm
Thickness
1.52 mm
Thickness
16 ga
Type
External Mounting for ProLine Industrial Enclosures
Weight
33 lb
Package Dimensions (L x W x H)
65 IN x 6 IN x 4 IN
Package Dimensions (L x W x H)
165.1 cm x 15.24 cm x 10.16 cm
Package Weight (Imperial)
33.000 L
Package Weight (Metric)
14.969 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the 100 mm Vented Plinth Base

This guide provides step-by-step instructions for replacing solid front and back panels with vented panels on a 100 mm plinth base.

Estimated time: 30m

Tools needed:

Screwdriver

Supplies needed:

Vented panels, Mounting screws

  1. Remove solid panels

    Unscrew and detach the solid front and back panels from the plinth base using a screwdriver.

  2. Prepare vented panels

    Align the vented panels with the mounting points on the plinth base, ensuring they fit securely.

  3. Attach vented panels

    Secure the vented panels to the plinth base using the provided mounting screws. Ensure all screws are tightened properly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.